GENERAL NOTES
<br />AIR LEAKAGE
<br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. SIM DETAIL
<br />SYMBOL
<br />2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL
<br />WORK. 101
<br />SIMILAR DETAIL
<br />3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND DETAIL NO
<br />INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND SHEET
<br />NO.
<br />OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE SIM
<br />ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE
<br />BUILDING CROSS SECTION BEDROOMS. (R315) 10
<br />4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE DETAIL
<br />NO.
<br />BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. SHEET NO.
<br />5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO
<br />MAKE THEM WATERPROOF. ROOF FLASHING PER R903. Room name ROOM NAME GUARDRAILS TO BE A MIN. OF 36"
<br />ABOVE FINISH FLOOR. (R312) ( EXCEPTIONS TO COMMERCIAL PER I. B.C.)
<br />7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER
<br />CANNOT PASS THROUGH.
<br />8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM
<br />NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF
<br />44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310. 1).
<br />SITEWORK
<br />1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL.
<br />(1 1/ 2- 3/8 CLEANWASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE
<br />AND WATERPROOFING.
<br />2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW
<br />FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES.
<br />3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND
<br />STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE
<br />CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES.
<br />THERMAL AND MOISTURE
<br />1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE
<br />OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS
<br />OR ON A SEPARATE ENERGY CALCULATION SHEET.
<br />2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS,
<br />FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES
<br />AND FLOORS BELOW GRADE.. (R406. 1)
<br />3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER
<br />MANUFACTURER'S INSTRUCTIONS.
<br />4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER INBETWEEN SLAB AND GRAVEL
<br />MECHANICAL
<br />1. PLUMBING SYSTEMS SHALL BE DESIGNED INACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES.
<br />2. HVAC SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND
<br />LOCAL CODES.
<br />PROVIDE DOCUMENTATION OF FURNACE A.F. U. E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON
<br />STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH THAT ALL PILOT LIGHTS,
<br />BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED AT MIN. OF 18" ABOVE THE GARAGE FLOOR.
<br />PERMT
<br /># B2201-048
<br />THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE
<br />REQUIREMENTS OF SECTIONS R402.4.1 THROUGH R402.4.4.
<br />R402.4.1 BUILDING THERMAL ENVELOPE. THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH SECTIONS
<br />R402.4.1.1 AND R402.4.1.2. THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR
<br />DIFFERENTIAL EXPANSION AND CONTRACTION.
<br />R402.4.1.1 INSTALLATION. THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE AS LISTED IN TABLE
<br />R402.4.1.1 SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE CRITERIA
<br />LISTED IN TABLE R402.4.1.1, AS APPLICABLE TO THE METHOD OF CONSTRUCTION. WHERE REQUIRED BY THE CODE
<br />OFFICIAL, AN APPROVED THIRD PARTY SHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE.
<br />R402.4.1.2 TESTING. THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN AIR
<br />LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER HOUR. TESTING SHALL BE CONDUCTED WITH A BLOWER
<br />DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50 PASCALS). FOR THIS TEST ONLY, THE VOLUME OF THE HOME SHALL
<br />BE THE CONDITIONED FLOOR AREA IN FT2 (M2) MULTIPLIED BY 8.5 FEET (2.6 M). WHERE REQUIRED BY THE CODE
<br />OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. A WRITTEN REPORT OF THE RESULTS
<br />OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL.
<br />TESTING SHALL BE PERFORMED AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL
<br />ENVELOPE. ONCE VISUAL INSPECTION HAS CONFIRMED SEALING (SEE TABLE R402.4.1.1), OPERABLE WINDOWS AND
<br />DOORS MANUFACTURED BY SMALL BUSINESS SHALL BE PERMITTED TO BE SEALED OFF AT THE FRAME PRIOR TO
<br />THE TEST.
<br />EXCEPTION:
<br />FOR DWELLING UNITS THAT ARE ACCESSED DIRECTLY FROM THE OUTDOORS, OTHER THAN DETACHED ONE
<br />FAMILY DWELLINGS AND TOWNHOUSES, AN AIR LEAKAGE RATE NOT EXCEEDING 0.4 CFM PER SQUARE FOOT OF
<br />THE DWELLING UNIT ENCLOSURE AREA SHALL BE AN ALLOWABLE ALTERNATIVE. TESTING SHALL BE CONDUCTED
<br />WITH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50 PASCALS) IN ACCORDANCE WITH RESNET/ICC 380,
<br />ASTM E779 OR ASTM E1827. FOR THE PURPOSE OF THIS TEST ONLY, THE ENCLOSURE AREA IS TO BE CALCULATED
<br />AS THE PERIMETER OF THE DWELLING UNIT, MEASURED TO THE OUTSIDE FACE OF THE EXTERIOR WALLS, AND THE
<br />CENTERLINE OF PARTY WALLS, TIMES 8.5 FEET, PLUS THE CEILING AND FLOOR AREA. DOORS AND WINDOWS OF
<br />ADJACENT DWELLING UNITS (INCLUDING TOP AND BOTTOM UNITS) SHALL BE OPEN TO THE OUTSIDE DURING THE
<br />TEST. THIS EXCEPTION IS NOT PERMITTED FOR DWELLING UNITS THAT ARE ACCESSED FROM CORRIDORS OR
<br />OTHER ENCLOSED COMMON AREAS.
<br />DURING TESTING:
<br />1. EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVE DOORS SHALL BE CLOSED, BUT
<br />NOT SEALED, BEYOND THE INTENDED WEATHERSTRIPPING OR OTHER INFILTRATION
<br />CONTROL MEASURES;
<br />2. DAMPERS INCLUDING EXHAUST, INTAKE, MAKEUP AIR, BACKDRAFT AND FLUE DAMPERS
<br />SHALL BE CLOSED, BUT NOT SEALED BEYOND INTENDED INFILTRATION CONTROL MEASURES;
<br />3. INTERIOR DOORS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE OPEN, ACCESS
<br />HATCHES TO CONDITIONED CRAWL SPACES AND CONDITIONED ATTICS SHALL BE OPEN;
<br />4. EXTERIOR OR INTERIOR TERMINATIONS FOR CONTINUOUS VENTILATION SYSTEMS AND
<br />HEAT RECOVERY VENTILATORS SHALL BE SEALED;
<br />5. HEATING AND COOLING SYSTEMS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE
<br />TURNED OFF; AND
<br />6. SUPPLY AND RETURN REGISTERS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE
<br />FULLY OPEN.
<br />EXCEPTIONS:
<br />1. ADDITIONS LESS THAN 500 SQUARE FEET OF CONDITIONED FLOOR AREA.
<br />2. ADDITIONS TESTED WITH THE EXISTING HOME HAVING A COMBINED MAXIMUM AIR
<br />LEAKAGE RATE OF 7 AIR CHANGES PER HOUR. TO QUALIFY FOR THIS EXCEPTION, THE
<br />DATE OF CONSTRUCTION OF THE EXISTING HOUSE MUST BE PRIOR TO THE 2009
<br />WASHINGTON STATE ENERGY CODE.
<br />BLUE MOON REALTY LLC
<br />PROPOSED SFR
<br />GENERAL NOTES
<br />DATE: 4/25/2022