Laserfiche WebLink
GENERAL NOTES <br />AIR LEAKAGE <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. SIM DETAIL <br />SYMBOL <br />2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL <br />WORK. 101 <br />SIMILAR DETAIL <br />3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND DETAIL NO <br />INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND SHEET <br />NO. <br />OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE SIM <br />ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE <br />BUILDING CROSS SECTION BEDROOMS. (R315) 10 <br />4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE DETAIL <br />NO. <br />BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. SHEET NO. <br />5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO <br />MAKE THEM WATERPROOF. ROOF FLASHING PER R903. Room name ROOM NAME GUARDRAILS TO BE A MIN. OF 36" <br />ABOVE FINISH FLOOR. (R312) ( EXCEPTIONS TO COMMERCIAL PER I. B.C.) <br />7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER <br />CANNOT PASS THROUGH. <br />8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM <br />NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF <br />44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310. 1). <br />SITEWORK <br />1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. <br />(1 1/ 2- 3/8 CLEANWASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE <br />AND WATERPROOFING. <br />2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW <br />FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. <br />3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND <br />STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE <br />CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. <br />THERMAL AND MOISTURE <br />1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE <br />OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS <br />OR ON A SEPARATE ENERGY CALCULATION SHEET. <br />2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS, <br />FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES <br />AND FLOORS BELOW GRADE.. (R406. 1) <br />3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER <br />MANUFACTURER'S INSTRUCTIONS. <br />4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER INBETWEEN SLAB AND GRAVEL <br />MECHANICAL <br />1. PLUMBING SYSTEMS SHALL BE DESIGNED INACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. <br />2. HVAC SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND <br />LOCAL CODES. <br />PROVIDE DOCUMENTATION OF FURNACE A.F. U. E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON <br />STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH THAT ALL PILOT LIGHTS, <br />BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED AT MIN. OF 18" ABOVE THE GARAGE FLOOR. <br />PERMT <br /># B2201-048 <br />THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF SECTIONS R402.4.1 THROUGH R402.4.4. <br />R402.4.1 BUILDING THERMAL ENVELOPE. THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH SECTIONS <br />R402.4.1.1 AND R402.4.1.2. THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR <br />DIFFERENTIAL EXPANSION AND CONTRACTION. <br />R402.4.1.1 INSTALLATION. THE COMPONENTS OF THE BUILDING THERMAL ENVELOPE AS LISTED IN TABLE <br />R402.4.1.1 SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE CRITERIA <br />LISTED IN TABLE R402.4.1.1, AS APPLICABLE TO THE METHOD OF CONSTRUCTION. WHERE REQUIRED BY THE CODE <br />OFFICIAL, AN APPROVED THIRD PARTY SHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE. <br />R402.4.1.2 TESTING. THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN AIR <br />LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER HOUR. TESTING SHALL BE CONDUCTED WITH A BLOWER <br />DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50 PASCALS). FOR THIS TEST ONLY, THE VOLUME OF THE HOME SHALL <br />BE THE CONDITIONED FLOOR AREA IN FT2 (M2) MULTIPLIED BY 8.5 FEET (2.6 M). WHERE REQUIRED BY THE CODE <br />OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD PARTY. A WRITTEN REPORT OF THE RESULTS <br />OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL. <br />TESTING SHALL BE PERFORMED AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL <br />ENVELOPE. ONCE VISUAL INSPECTION HAS CONFIRMED SEALING (SEE TABLE R402.4.1.1), OPERABLE WINDOWS AND <br />DOORS MANUFACTURED BY SMALL BUSINESS SHALL BE PERMITTED TO BE SEALED OFF AT THE FRAME PRIOR TO <br />THE TEST. <br />EXCEPTION: <br />FOR DWELLING UNITS THAT ARE ACCESSED DIRECTLY FROM THE OUTDOORS, OTHER THAN DETACHED ONE <br />FAMILY DWELLINGS AND TOWNHOUSES, AN AIR LEAKAGE RATE NOT EXCEEDING 0.4 CFM PER SQUARE FOOT OF <br />THE DWELLING UNIT ENCLOSURE AREA SHALL BE AN ALLOWABLE ALTERNATIVE. TESTING SHALL BE CONDUCTED <br />WITH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50 PASCALS) IN ACCORDANCE WITH RESNET/ICC 380, <br />ASTM E779 OR ASTM E1827. FOR THE PURPOSE OF THIS TEST ONLY, THE ENCLOSURE AREA IS TO BE CALCULATED <br />AS THE PERIMETER OF THE DWELLING UNIT, MEASURED TO THE OUTSIDE FACE OF THE EXTERIOR WALLS, AND THE <br />CENTERLINE OF PARTY WALLS, TIMES 8.5 FEET, PLUS THE CEILING AND FLOOR AREA. DOORS AND WINDOWS OF <br />ADJACENT DWELLING UNITS (INCLUDING TOP AND BOTTOM UNITS) SHALL BE OPEN TO THE OUTSIDE DURING THE <br />TEST. THIS EXCEPTION IS NOT PERMITTED FOR DWELLING UNITS THAT ARE ACCESSED FROM CORRIDORS OR <br />OTHER ENCLOSED COMMON AREAS. <br />DURING TESTING: <br />1. EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVE DOORS SHALL BE CLOSED, BUT <br />NOT SEALED, BEYOND THE INTENDED WEATHERSTRIPPING OR OTHER INFILTRATION <br />CONTROL MEASURES; <br />2. DAMPERS INCLUDING EXHAUST, INTAKE, MAKEUP AIR, BACKDRAFT AND FLUE DAMPERS <br />SHALL BE CLOSED, BUT NOT SEALED BEYOND INTENDED INFILTRATION CONTROL MEASURES; <br />3. INTERIOR DOORS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE OPEN, ACCESS <br />HATCHES TO CONDITIONED CRAWL SPACES AND CONDITIONED ATTICS SHALL BE OPEN; <br />4. EXTERIOR OR INTERIOR TERMINATIONS FOR CONTINUOUS VENTILATION SYSTEMS AND <br />HEAT RECOVERY VENTILATORS SHALL BE SEALED; <br />5. HEATING AND COOLING SYSTEMS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE <br />TURNED OFF; AND <br />6. SUPPLY AND RETURN REGISTERS, IF INSTALLED AT THE TIME OF THE TEST, SHALL BE <br />FULLY OPEN. <br />EXCEPTIONS: <br />1. ADDITIONS LESS THAN 500 SQUARE FEET OF CONDITIONED FLOOR AREA. <br />2. ADDITIONS TESTED WITH THE EXISTING HOME HAVING A COMBINED MAXIMUM AIR <br />LEAKAGE RATE OF 7 AIR CHANGES PER HOUR. TO QUALIFY FOR THIS EXCEPTION, THE <br />DATE OF CONSTRUCTION OF THE EXISTING HOUSE MUST BE PRIOR TO THE 2009 <br />WASHINGTON STATE ENERGY CODE. <br />BLUE MOON REALTY LLC <br />PROPOSED SFR <br />GENERAL NOTES <br />DATE: 4/25/2022 <br />A 10 <br />M <br />0 <br />co <br />N <br />N <br />O <br />N <br />N <br />yo <br />