My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2024-03-01
>
Address Records
>
75TH ST SE
>
1318
>
1318 75TH ST SE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 3:57:39 PM
Creation date
2/13/2024 11:03:33 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WoodWorks® Shearwalls Moon RES Lateral.wsw May. 17, 2022 10:06:02 <br />SHEATHING MATERIALS by WALL GROUP <br />Sheathing <br />I <br />Fasteners <br />Apply <br />Grp Surf <br />Material <br />Ratng <br />Thick <br />GU <br />Ply Or <br />Gvtv <br />Size <br />Type <br />Df <br />Eg <br />Fd <br />Bk <br />Notes <br />in <br />in <br />Ibs/in <br />in <br />in <br />1 Ext <br />Struct I OSB <br />32/16 <br />15/32 <br />5/8 <br />- Horz <br />835001 <br />10d <br />Box <br />N <br />6 <br />12 <br />Y <br />Int <br />Gyp WB 1-ply <br />1/2 <br />- <br />- Horz <br />40000 <br />5d <br />Nail <br />N <br />7 <br />7 <br />Y <br />5 <br />2 Ext <br />Struct I OSB <br />32/16 <br />15/32 <br />5/8 <br />- Horz <br />83500 <br />10d <br />Box <br />N <br />4 <br />12 <br />Y <br />2 <br />Int <br />Gyp WB 1-ply <br />1/2 <br />- <br />- Horz <br />40000 <br />5d <br />Nail <br />N <br />7 <br />7 <br />Y <br />5 <br />3 Ext <br />Structural 1 <br />32/16 <br />15/32 <br />- <br />3 Horz <br />350001 <br />10d <br />Box <br />N <br />6 <br />12 <br />Y <br />L Int <br />Gvp WB 1-plv <br />1/2 <br />Horz <br />400001 <br />5d <br />Nail <br />N <br />7 <br />7 <br />N <br />5 <br />Legend: <br />Grp — Wall Design Group number, used to reference wall in other tables (created by program) <br />Surf — Exterior or interior surface when applied to exterior wall <br />Ratng — Span rating, see SDPWS Table C4.2.2.2C <br />Thick — Nominal panel thickness <br />GU - Gypsum underlay thickness <br />Ply — Number of plies (or layers) in construction of plywood sheets <br />Or — Orientation of longer dimension of sheathing panels <br />Gvtv — Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.2A-B <br />Type — Fastener type from SDPWS Tables 4.3A-D: Nail — common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for <br />GWB, plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail; Casing — casing nail; Roof — roofing nail; Screw — <br />drywall screw <br />Size - Common, box, and casing nails: refer to SDPWS Table A 1 (casing sizes = box sizes). <br />Gauges: 11 ga = 0.120" x 1-314" (gypsum sheathing, 25132" fiberboard), 1-112" (lath & plaster, 112" fiberboard); 13 ga plasterboard = 0.92" x 1- <br />1/8". <br />Cooler or gypsum wallboard nail: 5d =. 086"x 1-5/8'; 6d =. 092" x 1-7/8'; 8d =. 113" x 2-3/8'; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. <br />Drywall screws: No. 6, 1-114"long. <br />518" gypsum sheathing can also use 6d cooler or GWB nail <br />Df— Deformed nails ( threaded or spiral), with increased withdrawal capacity <br />Eg — Panel edge fastener spacing <br />Fd — Field spacing interior to panels <br />Bk — Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) <br />Apply Notes — Notes below table legend which apply to sheathing side <br />Notes: <br />2. Framing at adjoining panel edges must be 3" nominal or wider with staggered nailing according to SDPWS 4.3.7.1.4 <br />5. This material does not contribute to seismic shear resistance because of the "Ignore non -wood -panel contribution for all walls" design setting. <br />FRAMING MATERIALS and STANDARD WALL by WALL GROUP <br />Wall <br />Species <br />Grade <br />b <br />d <br />Spcg <br />SG <br />E Standard Wall <br />Gr <br />in <br />in <br />in <br />psi^6 <br />1 <br />D.Fir-L <br />Stud <br />1.50 <br />5.50 <br />16 <br />0.50 <br />1.40 <br />2 <br />D.Fir-L <br />Stud <br />1.50 <br />5.50 <br />16 <br />0.50 <br />1.40 <br />3 <br />D.Fir-L <br />Stud <br />1.50 <br />5.50 <br />16 <br />0.50 <br />1.40 <br />Legend: <br />Wall Grp — Wall Design Group <br />b — Stud breadth (thickness) <br />d — Stud depth (width) <br />Spcg — Maximum on -centre spacing of studs for design, actual spacing may be less. <br />SG — Specific gravity <br />E — Modulus of elasticity <br />Standard Wall - Standard wall designed as group. <br />Notes: <br />Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. <br />Page 38 of 52 <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.