Laserfiche WebLink
8TC Hazards by Location <br /> Search Information CY <br /> Address: 1318 75th St SE, Everett,WA 98203, USA <br /> 5equim 482 ft,Je <br /> o <br /> Coordinates: 47.9300012,-122.2146755 WhidbeyJtt <br /> Island <br /> Elevation: 482 ft <br /> Timestamp: 2022-01-04T23:11:27.041 Z <br /> Hazard Type: Wind Redmond CD <br /> Seattle ° <br /> Go gle o Map data©2022 Google <br /> ASCE 7-16 ASCE 7-10 ASCE 7-05 <br /> MRI 10-Year 67 mph MRI 10-Year 72 mph ASCE 7-05 Wind Speed 85 mph <br /> MRI 25-Year 74 mph MRI 25-Year 79 mph <br /> MRI 50-Year 78 mph MRI 50-Year 85 mph <br /> MRI 100-Year 83 mph MRI 100-Year 91 mph <br /> Risk Category 1 92 mph Risk Category 1 100 mph <br /> Risk Category 11 98 mph Risk Category 11 110 mph <br /> Risk Category 111 105 mph Risk Category III-IV 115 mph <br /> Risk Category IV 109 mph <br /> The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building <br /> code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before <br /> proceeding with design. <br /> Disclaimer <br /> Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal <br /> areas outside the last contour should use the last wind speed contour of the coastal area—in some cases,this website will extrapolate past <br /> the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region <br /> boundaries,the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne <br /> debris region. <br /> Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. <br /> While the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibility <br /> or liability for its accuracy.The material presented in the report should not be used or relied upon for any specific application without <br /> competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals.ATC does <br /> not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge <br /> in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the <br /> report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of <br /> this wahsitP dnPs not imnly annrnval by the nnvarninn huildinn cnriP hndiPs rPsnnnsihlP fnr huildinn cndP annrnval ani' A*6Rtinn fnr the <br />