Laserfiche WebLink
HVAC LEGEND: <br />ABBREVIATIONS: <br />GENERAL NOTES: <br />GENERAL HVAC NOTES: <br />---------------- <br />RISE <br />�CC� RISE <br />24x12 <br />24x12 10x8 <br />I J <br />�J <br />1 � I <br />1 � I <br />0� <br />3OX20 <br />8"6 <br />EIN <br />1 r <br />T 6 <br />0 <br />SD <br />O n <br />�r <br />THERMOSTAT LINE <br />DIRECTION OF RISE FOR DUCT <br />DUCT (FIRST FIGURE DENOTES VIEW SHOWN) <br />SINGLE LINE DUCTWORK INDICATES DUCT <br />WITH VIEW DIMENSION LESS THAN 12 INCHES <br />DUCT TAKEOFF <br />SUPPLY DUCT TURNING TOWARD, UP <br />SUPPLY DUCT TURNING AWAY <br />RETURN DUCT TURNING TOWARD, UP <br />EXHAUST DUCT TURNING AWAY <br />EXHAUST DUCT TURNING TOWARD, UP <br />RETURN DUCT TURNING AWAY <br />ROUND DUCT TURNING TOWARD, UP <br />ROUND DUCT TURNING AWAY <br />OVAL DUCT TURNING TOWARD, UP <br />OVAL DUCT TURNING AWAY <br />CONICAL WYE <br />CONICAL TEE <br />VOLUME DAMPER(VD) <br />FIRE SMOKE DAMPER(FSD) <br />FIRE DAMPER(FD) <br />MOTORIZED DAMPER(FD) <br />DOUBLE LINE, LINED DUCT/ ACOUSTIC DUCT <br />RECTANGLE TO RECTANGLE FITTING RIGHT <br />ROUND TO ROUND HIGH/ MEDIUM VELOCITY FITTING <br />ROUND TO ROUND FITTING <br />LOW VELOCITY (PRESSURE) ROUND DUCT TAKE -OFF, <br />TO SUPPLY DIFFUSER <br />RECTANGLE/ ROUND RADIUSED ELBOW DUCT <br />RECTANGULAR 90` ELBOW W/ TURNING VANES TYPICAL <br />ECCENTRIC CONICAL DUCT REDUCTION FITTING <br />CONCENTRIC CONICAL DUCT REDUCTION FITTING <br />RECTANGLE TO ROUND FITTING <br />SOUND ATTENUATOR <br />TURNING VANES <br />FLEXIBLE DUCT <br />THERMOSTAT OR TEMPERATURE SENSOR <br />THERMOSTAT OR TEMPERATURE SENSOR (CEILING) <br />DUCT SMOKE DETECTOR <br />SUPPLY AIR DIFFUSER <br />ROUND SUPPLY AIR DIFFUSER <br />RETURN AIR GRILLE <br />EXHAUST AIR GRILLE <br />SIDEWALL SUPPLY AIR GRILLE <br />OR REGISTER <br />SIDEWALL RETURN/EXHAUST AIR <br />GRILLE OR REGISTER <br />AC <br />AIR CONDITIONING <br />IMC <br />INTERNATIONAL MECHANICAL CODE <br />ACE <br />AIR CURTAIN FAN <br />IPC <br />INTERNATIONAL PLUMBING CODE <br />ADA <br />AMERICAN DISABILITIES ACT <br />ID <br />INDIRECT DRAIN <br />ADJ <br />ADJUSTABLE <br />IE <br />INVERT ELEVATION <br />AFF <br />ABOVE FINISHED FLOOR <br />IN <br />INCH <br />AL <br />ACOUSTIC LINED <br />INSUL <br />INSULATE; INSULATION <br />ALIGN <br />ALIGNMENT <br />AP <br />ACCESS PANEL <br />KW <br />KILOWATT <br />APPROX <br />APPROXIMATELY <br />KWH <br />KILOWATTHOUR <br />ARCH <br />ARCHITECTURAL <br />ASME <br />AMERICAN SOCIETY OF MECHANICAL ENGINEERS <br />L <br />LENGTH <br />AVG <br />AVERAGE <br />LAT <br />LEAVING AIR TEMPERATURE <br />LB <br />POUNDS <br />HAS <br />BUILDING AUTOMATION SYSTEM <br />LF <br />LINEAL FOOT <br />ERE <br />BELOW FINISH FLOOR <br />_VG <br />LEAVING <br />BHP <br />BRAKE HORSEPOWER <br />BLDG <br />BUILDING <br />MA <br />MIXED AIR <br />DOD <br />BOTTOM OF DUCT <br />MAX <br />MAXIMUM <br />BOP <br />BOTTOM OF PIPE <br />MEN; MBUH <br />THOUSAND BRITISH THERMAL UNITS PER HOUR <br />BTU <br />BRITISH THERMAL UNIT <br />MCA <br />MINIMUM CIRCUIT AMPAC17Y <br />0TUH <br />BRJISH THERMAL UNITS PER HOUR <br />MCC <br />MOTOR CONTROL CENTER <br />BV <br />BALANCING VALVE <br />MD <br />MOTORIZED DAMPER <br />MECH <br />MECHANICAL <br />CD <br />CEILING DIFFUSER <br />MFR <br />MANUFACTURER <br />CFM <br />CUBIC FEET PER MINUTE <br />MIN <br />MINIMUM; MINUTE <br />CG <br />CEILING GRILLE <br />MISC <br />MISCELLANEOUS <br />CI <br />CAST IRON <br />MTD <br />MOUNTED <br />PE <br />CENTERLINE <br />MTG <br />MOUNTING <br />CLG <br />CEILING <br />CO <br />CLEANOUT <br />N.C. <br />NORMALLY CLOSED <br />CONN <br />CONNECT; CONNECTED; CONNECTION <br />N.O. <br />NORMALLY OPEN <br />CONST <br />CONSTRUCTION <br />NO <br />NOISE CRITERIA <br />CONT <br />CONTINUOUS; CONTINUATION <br />NIC <br />NOT IN CONTRACT <br />COORD <br />COORDINATE <br />NTS <br />NOT TO SCALE <br />CORR <br />CORRIDOR <br />CID <br />CONDENSING UNIT <br />OAT <br />OUTSIDE AIR TEMP <br />CU FT <br />CUBIC FEET <br />OD <br />OUTSIDE DIAMETER <br />Cu IN <br />CUBIC INCHES <br />OH <br />OVERHEAD <br />CA <br />OUTSIDE AIR <br />DB <br />DRY BULB TEMPERATURE <br />DEG <br />DEGREE <br />P <br />PUMP <br />DET <br />DETAIL <br />PD <br />PRESSURE DROP <br />DIA <br />DIAMETER <br />P <br />PHASE <br />DIFF <br />DIFFERENTIAL <br />R <br />PROPERTY LINE <br />DIM <br />DIMENSION <br />POC <br />POINT OF CONNECTION <br />DISCH <br />DISCHARGE <br />PRELIM <br />PRELIMINARY <br />ON <br />DOWN <br />PRES <br />PRESSURE <br />DR <br />DRAIN <br />PRV <br />PRESSURE REDUCING VALVE <br />DSD <br />DUCT SMOKE DETECTOR <br />PSI <br />POUNDS PER SQUARE INCH <br />DWG <br />DRAWING <br />PSIG <br />POUNDS PER SQUARE INCH GAGE <br />EA <br />EACH <br />RA <br />RETURN AIR <br />EAT <br />ENTERING AIR TEMPERATURE <br />RECIRC <br />RECIRCULATING <br />EF <br />EXHAUST FAN <br />RECT <br />RECTANGULAR <br />OFF <br />EFFICIENCY <br />REF <br />REFERENCE <br />EG <br />EXHAUST GRILLE <br />REG <br />REGULATOR <br />ELECT <br />ELECTRICAL <br />DECO <br />REQUIRED <br />ELEV <br />ELEVATION <br />RG <br />RETURN GRILLE <br />EMERG <br />EMERGENCY <br />RL <br />RE -LOCATE <br />ENT <br />ENTERING <br />RND <br />ROUND <br />ESP <br />EXTERNAL STATIC PRESSURE <br />RPM <br />REVOLUTIONS PER MINUTE <br />EXH <br />EXHAUST <br />RV <br />RELIEF VALVE <br />EXIST, (E) <br />EXISTING <br />EXP <br />EXPANSION <br />SCHED <br />SCHEDULE <br />SF <br />SQUARE FEET <br />F <br />FAHRENHEIT <br />SG <br />SUPPLY GRILLE <br />FC <br />FANCOIL <br />SO <br />SCREENED OPENING <br />FCO <br />FLOOR CLEANOUT <br />SOV <br />SHUT OFF VALVE <br />FO <br />FIRE DAMPER <br />Sp <br />STATIC PRESSURE <br />FIO <br />FURNISHED AND INSTALLED BY OWNER <br />SPEC <br />SPECIFICATION <br />FLA <br />FULL LOAD AMP <br />SPECD <br />SPECIFIED <br />FLEX <br />FLEXIBLE <br />SS <br />STAINLESS STEEL <br />FLR <br />FLOOR <br />STRUCT <br />STRUCTURAL <br />FOB <br />FLAT ON BOTTOM <br />END <br />SUPPLY WALL GRILLE <br />FOIC <br />FURNISHED BY OWNER INSTALLED BY CONTRACTOR <br />SWR <br />SUPPLY WALL REGISTER <br />TOT <br />FLAT ON TOP <br />FPM <br />FEET PER MINUTE <br />TBD <br />TO BE DETERMINED <br />FPS <br />FEET PER SECOND <br />TEMP <br />TEMPERATURE <br />FSD <br />FIRE SMOKE DAMPER <br />TSTAT <br />THERMOSTAT <br />FT <br />FOOT; FEET <br />THIRD <br />THROUGH <br />FU <br />FIXTURE UNITS <br />TOD <br />TOP OF DUCT <br />TOP <br />TOP OF PIPE <br />GAL <br />GALLON <br />TP <br />TRAP PRIMER <br />GALV <br />GALVANIZED <br />TS <br />TEMPERATURE SENSOR <br />GEN <br />GENERAL <br />TV <br />TURNING VANE <br />GND <br />GROUND <br />TYP <br />TYPICAL <br />GPH <br />GALLONS PER HOUR <br />GPM <br />GALLONS PER MINUTE <br />V <br />VENT <br />VD <br />VOLUME DAMPER <br />H <br />HEIGHT, HIGH <br />VEL <br />VELOCITY <br />HE <br />HORSEPOWER <br />VERT <br />VERTICAL <br />HR <br />HOUR <br />VOL <br />VOLUME <br />HTG <br />HEATING <br />HVAC <br />HEATING, VENTILATING, AND AIR CONDITIONING <br />WB <br />WET BULB TEMPERATURE <br />HZ <br />HERTZ <br />WET <br />WALL EXHAUST FAN <br />WG <br />WATER GAGE <br />IBC <br />INTERNATIONAL BUILDING CODE <br />W/ <br />WITH <br />IFGC <br />INTERNATIONAL FUEL GAS CODE <br />W/O <br />WITHOUT <br />WT <br />WEIGHT <br />PIPING LEGEND: <br />N.G. N.Q. BALL VALVE QA AUTOMATIC AIR VENTLOAT VALVE G- PIPE DOWN <br />4 <br />MANUAL AIR VENT <br />0-PIPE <br />UP <br />6 <br />BALL FLOAT VALVE <br />N.C. N.0. <br />DIFFERENTIAL PRESSURE GAUGE ASSEMBLY <br />9 <br />TEE DOWN <br />N.C. N.O. <br />BUTTERFLY VALVE <br />� <br />DIFFERENTIAL PRESSURE SENSOR ASSEMBLY <br />O <br />TEE UP <br />III <br />UNION <br />wr <br />N.C. � N.O. <br />GALL VALVE <br />GAUGE W/ COCK <br />tl <br />CLEAN OUT <br />P/T PORT <br />yr <br />IN 1, D" N.O. <br />GLOBE VALVE <br />D <br />REDUCER <br />.C. <br />y <br />4 <br />PIPE WELL THERMOMETER <br />WYE STRAINER <br />N <br />CHECK VALVE <br />Y <br />FLOW METER <br />Y <br />FLOW SENSOR <br />PLUG VALVE <br />PRESSURE REGULATING VALVE <br />1 BTU METER W/ WELL SENSOR <br />MOTORIZED VALVE ACTUATOR <br />SOLENOID VALVE ACTUATOR <br />PRESSURE RELIEF VALVE <br />1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF INTERNATIONAL <br />BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), WASHINGTON STATE ENERGY CODE (WSEC), INTERNATIONAL <br />PLUMBING CODE (UPC), INTERNATIONAL FUEL GAS CODE (IFGC), INTERNATIONAL FIRE CODE (IFC), NFPA AND HEALTH CODES AND <br />REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. <br />2. CONTRACTOR SHALL COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS AND DUCT ROUTING CLEARANCES NTH THE <br />STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. <br />3. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE AND SERVICE FOR ALL MECHANICAL <br />EQUIPMENT AND UNITS. REFER TO MANUFACTURER'S INSTALLATION GUIDE. <br />4. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE <br />5. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED <br />BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS <br />MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE PROJECT MANAGER BEFORE <br />BEING INSTALLED, DO NOT SCALE DRAWINGS. <br />6. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA/OCCUPATION SEPARATION WALLS. ALL PIPE, <br />DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. <br />7. ALL EQUIPMENT, DAMPERS, PIPING, AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. <br />ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. COORDINATE LOCATIONS WITH <br />ARCHITECT/OW'NER/CONTRACTOR TO PROVIDE ACCESS DOORS. <br />8. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND SHALL BE OF THE KIND AND QUALITY <br />DESCRIBED HEREIN. <br />9. ALL EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE STATE OF WASHINGTON AND SHALL HAVE ALL CERTIFICATIONS <br />AND RATINGS REQUIRED TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. <br />10. VERIFY ALL THE MECHANICAL EQUIPMENT'S ELECTRICAL LOADS VOLTAGE/PHASE, ETC. 'NTH ELECTRICAL CONTRACTOR PRIOR TO <br />ORDERING. <br />11. WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS ARE USED, BALANCING VALVES IN THE RETURN LINES ARE REQUIRED. A CHECK <br />VALVE SHALL BE PROVIDED IN EACH RETURN TO PREVENT TEMPORARY REVERSAL OF FLOW. <br />12. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL WORK, ETC., SHOWN ON <br />CONTRACT DOCUMENT DRAWINGS. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED <br />NTH ALL OTHER TRADES INVOLVED. <br />13. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. <br />14. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF ONE MANUFACTURER SHALL <br />BE USED. <br />15. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. <br />16. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF <br />OCCUPANCY AS REQUIRED BY SECTION C103.6 OF 2018 WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE <br />DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A <br />MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON <br />A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. <br />18. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED NTH ALL OTHER TRADES INVOLVED. <br />2018 WASHINGTON STATE <br />ENERGY CODE (WSEC) NOTES <br />1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED <br />IN C403.3.2. <br />2. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING <br />UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.4.2 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL <br />SEQUENCES, IF PROVIDED. <br />3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.22.1 <br />AND C408.2.2.2 OF THE WSEC AND CHAPTER 6 OF THE IMC AND AS INDICATED ON THE CONTRACT DOCUMENTS. <br />4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL <br />BE SEALED AS REQUIRED BY SECTION C403.10.2 OF THE WSEC. DUCT TAPE NOT ALLOWED. <br />5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.10.1 OF THE WSEC. <br />6. ALL PIPING INSULATION SHALL CONFORM TO SECTION C403.10.3 OF THE WSEC. <br />7. FAN OF GREATER THAN 5 HE SHALL HAVE A FAN EFFICIENCY GRADE (FEG) OF 67 OR HIGHER AS REQUIRED BY SECTION C403.8.3 <br />OF THE WSEC. <br />8. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER SECTIONS C405.8 OF THE WSEC FOR FULL LOAD <br />EFFICIENCIES. MOTORS BETWEEN 1/12 HP AND 1 HP NOT COVERED BY TABLES C405.8(3) AND C405.8(4) SHALL BE ELECTRICALLY <br />COMMUTATED MOTORS. <br />9. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2 OF THE WSEC. <br />10. HVAC SYSTEMS DO NOT REQUIRE COMMISSIONING PER THE WSEC SECTION C408.2 EXCEPTION 1. <br />11. HVAC SYSTEMS SHALL BE EQUIPPED NTH DEDICATED OUTDOOR AIR SYSTEMS (DOAS) AS REQUIRED BY SECTION C403.3.5 OF THE <br />WSEC. <br />12. HVAC SYSTEMS SHALL BE EQUIPPED WITH 100% OUTSIDE AIR ECONOMIZERS AS REQUIRED BY SECTION C403.3 OF THE WSEC. <br />13. HVAC SYSTEMS SHALL BE EQUIPPED WITH INTEGRATED ECONOMIZERS AS REQUIRED BY SECTION C403.5.1 THE WSEC. <br />14. FRESH AIR INTAKE AND RELIEF/EXHAUST SHALL BE EQUIPPED WITH LOW LEAK CLASS 1A MOTORIZED DAMPERS AS REQUIRED BY <br />SECTION C403.7.8 OF THE WSEC. <br />15. FAN AND PUMP MOTORS 7.5 HE AND GREATER SHALL BE EQUIPPED WITH A VFD AS REQUIRED BY SECTION C403.2.3 OF THE <br />WSEC, <br />16. IF NOT SPECIFICALLY STATED ABOVE, CONTRACTOR SHALL COMPLY WITH THE WSEC ITEMS THAT DO APPLY TO THIS PROJECT. <br />1. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND <br />GENERAL ARRANGEMENT ONLY. <br />2. INSTALL ALL DUCT MOUNTED SENSING AND CONTROL DEVICES IN LOCATIONS VWTH STRAIGHT SECTION OF DUCT UP AND <br />DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER FOR GOOD ACCURACY AND ACCESSIBILITY. <br />3. COORDINATE AND PROVIDE ALL DUCT TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. <br />FIELD VERIFY AND COORDINATE ALL DUCT DIMENSIONS BEFORE FABRICATION. <br />4. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION, AND <br />SEISMICALLY BRACED AS REQUIRED. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION <br />OF VIBRATION TO BUILDING STRUCTURE. <br />5. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK ACCESS DOORS VOLUME DAMPERS ETC. ARE INDICATED ON THE <br />CONTRACT DOCUMENT DRAWINGS FOR CLARITY FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS <br />THE EXTENT OF THE REQUIREMENTS FOR THESE ITEMS. <br />6. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS 4'-0" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY THE PROJECT <br />MANAGER OF ANY ROOMS WHERE THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. <br />7. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. <br />8. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF THE STRUCTURE (WITHIN TRUSSES), WITH <br />SPACE FOR INSULATION IF REQUIRED. <br />9. MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE AS CODE PERMITS. <br />10. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND <br />TRANSITIONS AROUND OBSTRUCTIONS. <br />11. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL VOLUME DAMPERS AND OTHER ITEMS LOCATED IN THE <br />DUCTWORK WHICH REQUIRE SERVICE AND/OR INSPECTION. <br />12. ALL AIR DISTRIBUTION SUPPLY OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. <br />13. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. <br />14. ALL FAN SYSTEMS WITH OVER 2000 CFM SHALL HAVE DUCT SMOKE DETECTORS IN THE RETURN AIR STREAM TO DISABLE FAN <br />UPON SMOKE DETECTION DETECTION. DUCT SMOKE DETECTORS ARE NOT REQUIRED IN THE RETURN AIR STREAM WHERE ALL <br />PORTIONS OF THE BUILDING SERVED BY THE AIR DISTRIBUTION SYSTEM ARE PROTECTED BY AREA SMOKE DETECTORS CONNECTED <br />TO A FIRE ALARM SYSTEM IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE. THE AREA SMOKE DETECTION SYSTEM SHALL <br />COMPLY WITH SECTION 606.4 OF THE IMC. DUCT/SMOKE DETECTORS SHALL BE LISTED BY AN APPROVED AGENCY AND FOR <br />INSTALLATION IN AIR DUCTS PER IMC SECTION 606. <br />15. ALL MECHANICAL HEATING AND VENTILATION EQUIPMENT SHALL CONFORM TO SMACNA, LOCAL AND STATE REGULATIONS FOR <br />SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). <br />16. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. <br />17. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUND LINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. <br />ALL DUCT LINING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET IMC CHAPTER 6. <br />18. ALL DUCTWORK TO BE CLASS-1 AIR DUCTS. CLASS -II DUCTS SHALL NOT BE USED. <br />SITE INFO <br />ADDRESS: 2729 COLBY AVE <br />EVERETT, WA 98034 <br />OWNER: WILCOX SHARON M <br />PARCEL/TAX N 00439162501300 <br />LEGAL: EVERETT PLAT OF BILK 625 D-00 - LOTS 13 14 15 & 16 <br />PROJECT LOCATION S l � L V I C I N I I Y _�� <br />NTS �/ <br />� c <br />ro <br />Q Q <br />Uro 0 <br />C U <br />,170 u <br />N T J <br />ru V) 4J <br />Lj <br />c QJ <br />U `� V' <br />^, U Q <br />W c <br />5 � <br />w <br />am <br />3132 N.E. 133 ST <br />Seattle, Washington 981254423 <br />PO Box 27073 <br />Seattle, Washington 98165-1473 <br />(206) 367-2500 <br />Fax (206)368-6856 <br />PSRMEML809G6 <br />CLL <br />G <br />Za <br />rwn <br />V w <br />w <br />_J = v <br />W th <br />0 <br />oZj O Q a <br />< <br />Lu <br />LL <br />J <br />LLI LL O O W <br />//2J /�0�nLul <br />W <br />O N W <br />V <br />W <br />Ow <br />Uz <br />Q <br />COPYRIGHT NO`RCE <br />His AOUTMESIGN is AN UNPUBLISHED <br />WORK,AND PUGETSOUND <br />rvT ANY UNAUTHORIZED COPY NG. <br />PlILILATION OR USE OF THIS DESIGN, <br />No. BevlsronnssUe Date <br />C�STONE <br />10/16/2023 <br />A KWON <br />10/16/2023 <br />P5812 ee, <br />D.M. M O.O <br />AS NOTED <br />