Laserfiche WebLink
Store No.: QFC862 DESIGN AMBIENT: 85 DATE F1 DATE • <br /> KMA: QFC VOLTAGE: 460V/3PH BY: E. RUWE 11/7/22 N/A 0 <br /> DISTRIBUTED UNIT INFORMATION <br /> CASEICOIL ePRO EVAP LOAD CON- DEFROST TOTAL SUCT PERCENT <br /> UNIT CKT L W H MODEL DESCRIPTION DEPT STAT ITEM ITEMP� (MBHJ TROL #/DAY TYPE REFRIG LOAD COMPRESSOR HP TEMP CAPACITY THR LOADED �~ m <br /> W <br /> H <br /> 1 R448A NEW DISTRIBUTED UNIT Without Sound Attenuation Kit V Z) <br /> REMOTE HEADER"A/AR" Reclaim:Water,See RISD-12B, Ship Loose 3-Way Reclaim Valve •��.~.yI <br /> 1 Al 12 24 8 EXIST COIL(S) FREEZER GROC. EX -22 23.9 EVR GAS Controller: Danfoss AK-SM 880A ILl N <br /> 2 A2 1 QTY RLN(IC-G-LED)-3 3 DOOR G.D., ICE CREAM TEMP, NARROW BAK. EX -19 3.5 EVR 1 GAS/TIME Control Voltage:208V p <br /> 3 A3 2 QTY FW(DT-E)-12 12'WIDE ISLAND, DUAL TEMP MEAT EX -20 12.6 EVR 1 EL/TEMP Control Valve Voltage: 208V O 00 <br /> 2 QTY FWE(DT-E) WIDE ISLAND END, DUAL TEMP MEAT EX -20 4.2 1 EL/TEMP Compressor Voltage:460V �I Z <br /> 4 A4 4 QTY RLN(LT-G-LED2)-5 5 DOOR G.D., LOW TEMP, NARROW GROC. EX -11 19.1 (S)ORIT 1 GAS/TIME *Condenser to be fed from distributed unit � O <br /> 1 QTY RLN(LT-G-LED2)-3 3 DOOR G.D., LOW TEMP, NARROW GROC. EX -11 2.9 1 GAS/TIME **New remote header w/receiver provided by Kysor Warren, W (~r, <br /> 5 A5 2 QTY RLNI(IC-G-LED2)-5 5 DOOR G.D., ICE CREAM TEMP, NARROW, BACK-TO-BACK GROC. EX -19 9.7 1 GAS/TIME To be fed from building electric > Z <br /> 2 QTY RLN(IC-G-LED2)-2 2 DOOR G.D., ICE CREAM TEMP, NARROW GROC. EX -19 4.3 1 GAS/TIME ***OEM to ship loose 3-way split condensing valve Q 2 <br /> A5A 1 QTY RLN(LT-G-LED2)-5 5 DOOR G.D., LOW TEMP, NARROW SEAF. EX -11 4.8 1 GAS/TIME U) <br /> COMBO CIRCUIT EVR Suction Temperature:-25°Midpoint,-21.9°Dewpoint(8.7 PSIG Setpoint) <br /> 6 A6 4 QTY RLNI(LT-G-LED2)-5 5 DOOR G.D., LOW TEMP, NARROW, BACK-TO-BACK GROC. EX -11 17.3 SORIT 1 GAS/TIME Condensing Temperature: 97°Midpoint ro <br /> 1 QTY RLNI(LT-G-LED2)-3 3 DOOR G.D., LOW TEMP, NARROW, BACK-TO-BACK GROC. EX -11 2.6 1 GAS/TIME � Z <br /> 7 A7 2 QTY RLNI(IC-G-LED2)-5 5 DOOR G.D., ICE CREAM TEMP, NARROW, BACK-TO-BACK GROC. EX -19 9.7 EVR 1 GAS/TIME ZFD41K5E Digital, Economized 50° 47.8 74.8 ,It W <br /> 1 QTY RLNI(IC-G-LED2)-3 3 DOOR G.D., ICE CREAM TEMP, NARROW, BACK-TO-BACK GROC. EX -19 2.9 1 GAS/TIME ZF41K5E Economized 50° 47.8 74.8 <br /> 2 QTY RLN(IC-G-LED2)-2 2 DOOR G.D., ICE CREAM TEMP, NARROW GROC. EX -19 4.3 1 GAS/TIME ZF41K5E Economized 50° 47.8 74.8 <br /> 8 A8 2 QTY OMZD-5 SINGLE DECK BAK. EX -17 3.9 EVR 2 EL/TEMP <br /> 9 A-SP1 SPARE 125.5 143.3 224.4 87.6% <br /> REMOTE HEADER"A/AR" Suction Temperature: 18°Midpoint, 21.6°Dewpoint(46.2 PSIG Setpoint) <br /> 10 AR9 1 QTY M5XEP(LED)-12 12'FIVE DECK MEAT EX 26 16.4 EVR 4 OT/TIME Condensing Temperature: 97°Midpoint <br /> 1 QTY M5XEP(LED)-8 8'FIVE DECK MEAT EX 26 10.9 4 OT/TIME <br /> 11 AR10 2 QTY M5XEP(LED)-8 8'FIVE DECK MEAT EX 26 21.8 EVR 4 OT/TIME ZB114K5E 130.1 172.7 STAMP: <br /> 12 AR11 2 QTY C2(X)LGEP(M)-12 12'MULTI-DECK,48"HIGH BACK, LOW FRONT,W/G(FRESH MEAT) MEAT EX 23 14.3 EVR 2 OT/TIME ZB114K5E 130.1 172.7 <br /> 13 AR13 1 QTY C2XXLGEP(M)-6 6 MULTI-DECK, LOW FRONT,W/G(FRESH MEAT) SEAF. EX 23 5.1 EVR 2 OT/TIME ZBD114K5E Digital 135.0 176.3 <br /> 14 AR15 8 8 8 EXIST COIL(S) COOLER SEAF. EX 20 6.9 EVR GAS <br /> 15 AR16 12 40 8 EXIST COIL(S) COOLER MEAT EX 20 26.9 EVR GAS 377.8 395.2 521.7 95.6% <br /> 16 AR17 1 QTY ESBDS-8 8'SERVICE DELI. EX 20 2.8 EX @ CASE 2 OT/TEMP <br /> 1 QTY ESBDS-12 12'SERVICE DELI. EX 20 4.3 2 OT/TEMP <br /> AR17A 1 QTY SSFO-12R 12'OPEN SERVICE FISH SEAF. EX 24 5.4 EX @ CASE 4 OT/TIME <br /> AR17B 1 QTY ESGMS-12 12'SERVICE MEAT EX 22 3.2 EX @ CASE 1 OT/TIME <br /> COMBO LOOP BV @ HEADER REVISIONS <br /> REMOTE HEADER"B" D DATE DESCRIPTION <br /> 1 B18 3-6" 12 8 EXIST COIL(S) COOLER MEAT EX 29 8.6 EX @ CASE OT <br /> B21 7 QTY DD5XLP-12 12'FIVE DECK WITH DOORS DELI. EX 32 22.8 EX @ CASE 1 OT/TIME <br /> 1 QTY DD5XLP-4 4'FIVE DECK WITH DOORS DELI. EX 32 1.1 1 OT/TIME <br /> COMBO LOOP BV @ HEADER <br /> 2 B22A 2 QTY IM-04-E5(DELI) MULTI-DECK SELF SERVICE END DELI. EX 28 6.9 EX @ CASE 6 OT/TIME <br /> 1 QTY IM-04-C8-R(DELI) 8'UNITIZED MULTI-DECK ISLAND DELI. EX 28 11.0 6 OT/TIME <br /> B22B 2 QTY IM-04-E5(DELI) MULTI-DECK SELF SERVICE END DELI. EX 28 6.9 EX @ CASE 6 OT/TIME <br /> 1 QTY IM-04-C8-R(DELI) 8'UNITIZED MULTI-DECK ISLAND DELI. EX 28 11.0 6 OT(TIME <br /> B22C 2 QTY DD5XLP-8 8'FIVE DECK WITH DOORS DELI. EX 32 4.3 EX @ CASE 1 OT/TIME <br /> B23 12 9 8 EXIST COIL(S) COOLER DELI. EX 26 8.6 EX @ COIL <br /> COMBO LOOP BV @ HEADER <br /> 3 B27 28 16-6" 8 LCA6160S 1/2 COOLER W/(11)DOORS DAIRY EX 26 18.8 EX @ COIL <br /> LCA6160S 1/2 COOLER W/(11)DOORS DAIRY EX 26 18.8 <br /> B28 1 QTY DD5XLP-6 6'FIVE DECK WITH DOORS DAIRY EX 32 1.6 EX @ CASE 1 OT/TIME <br /> 2 QTY DD5XLP-12 12'FIVE DECK WITH DOORS DAIRY EX 32 6.5 1 OT/TIME <br /> B30 11 32 8 EXIST COIL(S) COOLER PROD. EX 26 21.6 EX @ COIL 66 ?� <br /> COMBO LOOP BV @ HEADER w ON <br /> 4 B31 40 FT DMZ(GL DR) VERTICAL SHELF,GL DR RETROFIT DAIRY EX 32 15.0 EX @ CASE o cc <br /> rn <br /> B33 3 QTY D5XLEP-12 12'FIVE DECK, LOW FRONT PROD. EX 26 45.5 EX @ CASE 3 OT/TIME a N <br /> Q <br /> 1 QTY D5XLEP-6 6'FIVE DECK, LOW FRONT PROD. EX 26 7.6 3 OT/TIME Lo N <br /> co 1 QTY D5XLEP-4 4'FIVE DECK, LOW FRONT PROD. EX 26 5.1 3 OT/TIME W Y <br /> B34 2 QTY BLF-59SR SELF SERVICE BAK. EX 20 11.3 EX @ CASE 4 OT/TIME W U <br /> B35 1 QTY BLF-59R SERVICE BAK. EX 20 3.3 EX @CASE 4 OT/TIME � LL <br /> LL <br /> B36 1 QTY FL5NX a <br /> LEP-8 8'MULTI DECK, LOW FRONT, NARROW FLOR. EX 28 10.6 EX @ CASE 3 OT(TIME <br /> 5 B39 4 QTY DD5XLP-12 12'FIVE DECK WITH DOORS BEV. EX 32 13.0 SORIT 1 OT/TIME <br /> 6 B-SP1 SPARE <br /> 7 B-SP2 SPARE <br /> 8 B-SP3 SPARE z; <br /> 01 N <br /> ........................_.._..._..,......_,................_...._,.....,_......__..,..,.._.....__........................................................................................................................................................................................................................,................. Z rn <br /> M w <br /> o <br /> TOTAL THR: 746.2 N <br /> N� pr <br /> NEW 460V Air Cooled Condenser Wo o 01 < <br /> s = N <br /> � <br /> BOHN BNH-D10-A088(10 FPI), 86.24 mbh/deg td capacity, 56 circuits c3" o a`" a <br /> 12 Degree Set Point/Operating TD <br /> NEMA 1 VFD: Danfoss 1781-12584(K-0060172) R2. <br /> *O <br /> Refrigeration <br /> Schedule <br />