Laserfiche WebLink
PLANS PREPARED FOR: <br /> NOTES: CONNECTIONTO \\ "C"CLAMP <br /> CABLE LADDER p \ SUPPORT T Mobile <br /> 1. CONTRACTOR SHALL FIELD VERIFY ALL CABLE LADDER GROUND BOUND STRAP I AND <br /> LENGTHS,PRIOR TO INSTALLATION. BOTH SIDES(TYP.) BRACKET <br /> 2. ALL CUT ENDS OF CABLE LADDER TO BE FILED SMOOTH AND C"CLAMP \ <br /> PAINTED WITH MATCHING COLOR. �— <br /> 19807 NORTH CREEK PKWY N <br /> BOTHELL,WA 98011 <br /> 3. BOTTOM OF CABLE LADDER TO BE 7'-6"ABOVE FINISH FLOOR. A <br /> UNLESS NOTED OTHERWISE. <br /> 4. CORNER BRACKETS TO BE ON THE INSIDE,UNLESS LADDER <br /> RUNGS PLANS PREPARED BY: <br /> INTERFERE,THEN CORNER BRACKETS MAY BE ON THE OUTSIDE. 3/8"0 LAG SCREW <br /> 5. CABLE LADDER RUNGS TO BE ON TOP OF HORIZONTAL LADDER ALIGNMENT SLEEVE(TYP) EMBEDDED 2"MIN(TYP) Technology Associates <br /> AND AWAY FROM WALL ON VERTICAL LADDERS. B GROUND BOUNDSTRAP CONNECTION TO WALL <br /> 6. NUTS TO BE ON BOTTOM OF ASSEMBLY,OR TOWARDS WALL. PLAN VIEW (ONE SIDE ONLY) 24"x6"x2"BATTEN BOARD <br /> 7. 5/8"THREADED RODS,SUPPORTING CABLE LADDER,SPACED 3/8"0 LAG SCREW SEATTLE MARKET OFFICE <br /> 6'-0"APART. EMBEDDED 2"MIN(TYR) 9725 3RD AVENUE NE,STE.410 <br /> 8. AFTER FINAL LEVELING OF CABLE LADDER CUT ROD SO THAT SEATTLE,WA 98115 <br /> 1/2"OF THE THREADS ARE EXPOSED BELOW THE NUT.CAP EACH <br /> OCCURRENCE WITH PROPERLY SIZED VINYL VOLT CAPS. UNISTRUT <br /> 9. ANCHOR ALL ENDS OF CABLE LADDER TO WALL. P1000T JURISDICTION APPROVAL SEAL: <br /> SPRINT NUT <br /> 10. INSTALL UNISTRUT AS REQUIRED,OTHERWISE s"0 THREADED <br /> ATTACHED DIRECTLY TO CEILING. ROD THREADED <br /> 11. ENSURE NEW BLOCKING IS INSTALLED IN WALL AND CEILING TO "C"CLAMP <br /> ACCEPT LAG SCREWS AND OTHER EMBEDMENT REQUIREMENTS. BRACKET <br /> SECTION A CABLE LADDER,SEE—//' <br /> EE SECTION B <br /> PLAN FOR LOCATIONS <br /> SCALE SCALE SCALE <br /> 7 <br /> N.T.S. 10 N.T.S. I CABLE LADDER N.T.S. <br /> ENGINEERING SEAL: <br /> DELTA:225A PDU(ESGC225-HCU21) <br /> DIMENSIONS: 17.15"x 6.81"x 13.90" <br /> WEIGHT: 88 Ibs <br /> OPERATING TEMPERATURE: -40°C UP TO+65*C OR 60°C x`O <br /> INPUT �.\G <br /> Wbw Gin%ph—;110V l24W.2N-PE(L1.1.2%Fr) ,! V <br /> m..w azAm.x zx `GJ` <br /> FmymneT 5Q2pR: Cl <br /> OUTPUT GO <br /> Vdbw(ddb.l �V. GO� <br /> Vcbtpelml�mmle v,pe) iib SSVm <br /> M—I 225AmmC blal O <br /> Muunum Pacer®mnimi Ypd 12.2 <br /> Lmtl: Bcevlmrpm.20xbml <br /> Pars 01WEWona Gwr. is ft.pmltlm,gal Bu! 9h(marl <br /> GMC 18AmucMe,Bz <br /> LVDS Fd,id.tl <br /> DRAWING NOTICE: <br /> THESE DOCUMENTS ARE CONFIDENTIAL <br /> AND ARE THE SOLE PROPERTY OF <br /> a T-MOBILE AND MAY NOT BE REPRODUCED, <br /> N DISSEMINATED OR REDISTRIBUTED <br /> w - <br /> WITHOUT THE EXPRESS WRITTEN <br /> Wr <br /> CONSENT OF T-MOBILE. <br /> a <br /> 0 <br /> REVISIONS: <br /> Q FRONT AND REAR VIEWS DESCRIPTION DATE BY REV <br /> z <br /> W ISSUED FOR 90%GAS CO 0B/31Y2023 EL A <br /> � SCALE SCALE Q SCALE SCALE <br /> o N.T.S. N.T.S. N.T.S. 5 225A PDU (ESGC225-HCU11) N.T.S. 2 ISSUED FOR 100%DAS CD 09/07/2023 MGM 0 <br /> w <br /> w ELTEK 1U 12-WAY MCB DISTRIBUTIONS <br /> 0 <br /> 0 <br /> SITE NAME: <br /> p <br /> CUI UTOITA ANGEL OF THE <br /> WINDS ARENA <br /> v SITE NUMBER: <br /> a <br /> SEYH 102A <br /> SITE ADDRESS: <br /> a <br /> 2000 HEWITT AVE <br /> o EVERETT,WA 98201 <br /> N <br /> R _ caaamer btlm"� unn / g1p0my SHEET DESCRIPTION: <br /> w.w 1 DETAILS <br /> W <br /> 2 <br /> H <br /> w FRONT AND REAR VIEWS SHEET NUMBER: <br /> H <br /> = SCALE 12 SCALE ^ SCALE 6 SPLITTER SCALE A-6 <br /> N.T.S. N.T.S. `� N.T.S. I N.T.S. <br />