My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 SEINER DR 2024-04-12
>
Address Records
>
SEINER DR
>
1410
>
1410 SEINER DR 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 7:40:58 AM
Creation date
2/14/2024 9:41:31 AM
Metadata
Fields
Template:
Address Document
Street Name
SEINER DR
Street Number
1410
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> ® NOTIFIER <br /> �/�. <br /> by Honeywell <br /> NP-200 Series Photoelectric Smoke Detectors for FireWarden Series <br /> The NOTIFIER®NP-200 Series intelligent plug-in smoke detectors <br /> are designed for both performance and aesthetics, and are direct <br /> replacements for the NP-100 Series.A new modern,sleek,contem- <br /> porary design and enhanced optical sensing chamber is engineered <br /> to sense smoke produced by a wide range of combustion sources in <br /> accordance with more stringent code standards. <br /> Exclusively for use with NOTIFIER's FireWarden Series address- <br /> able fire alarm control panels,the NP-200 Series point ID capability <br /> allows each detector's address to be set with rotary, decimal <br /> address switches, providing exact detector location for emergency <br /> personnel to quickly locate a fire during its early stages, potentially <br /> saving precious rescue time while also reducing property damage. <br /> Two LEDs on each sensor light to provide a local,visible sensor indi- <br /> cation. w <br /> The NP-200 Series also offers 135°F(57°C)fixed temperature ther- <br /> mal <br /> sensing on the NP-200T and a remote test capable detector on <br /> the NP-200R for use with DNR(A)/DNRW duct smoke detector <br /> housings. <br /> Features • Separate base allows interchange of photoelectric,ionization and <br /> SLC LOOP: thermal sensors <br /> • Two-wire SLC loop connection OPTIONS: <br /> • Unit uses base for wiring • Optional relay,isolator,and sounder bases <br /> • Compatible with FlashScan®and CLIP protocol systems Installation <br /> • Stable communication technique with noise immunity <br /> NP-200 Series plug-in intelligent smoke detectors use a detachable <br /> ADDRESSING: base to simplify installation, service and maintenance. Installation <br /> • Addressable by device instructions are shipped with each detector. <br /> • Rotary,decimal addressing Mount detector base(all base types)on an electrical backbox which <br /> (Refer to the FireWarden panel manuals for device capacity.) is at least 1.5" (3.81 cm) deep. For a chart of compatible junction <br /> ARCHITECTURE: boxes,see DN-60054. <br /> • Sleek,low profile,stylish design NOTE:Because of the inherent supervision provided by the SLC loop, <br /> end-of-line resistors are not required. Wiring "T-taps"or branches are <br /> • Unique single-source design to respond quickly and dependably permitted for Style 4(Class"B")wiring only. <br /> to a broad range of fires When using relay or sounder bases, consult the N100-ISO installation <br /> • Integral communications and built-in device-type identification sheet 156-3625 for device limitations between isolator modules and iso- <br /> lator bases. <br /> • Built-in tamper resistant feature <br /> • Remote test feature from the panel Construction <br /> • Walk test with address display(an address on 121 will blink the These detectors are constructed of fire-resistant plastic.The NP-200 <br /> detector LED:12-[pause]-1(FlashScan systems only) Series plug-in intelligent smoke detectors are designed to commer- <br /> • Built-in functional test switch activated by external magnet cial standards and offer an attractive appearance. <br /> • Removable cover and insect-resistant screen for simple field <br /> cleaning Operation <br /> • Expanded color options Each NP-200 Series detector uses one of the panel's addresses <br /> (total limit is panel dependent)on the FireWarden Signaling Line Cir- <br /> OPERATION: cult (SLC). It responds to regular polls from the control panel and <br /> • Designed to meet UL 268 7th Edition reports its type and the status.If it receives a test command from the <br /> • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- panel (or a local magnet test), it stimulates its electronics and <br /> old level reports an alarm. It blinks its LEDs when polled and turns the LEDs <br /> fea- <br /> • LED"blinks"when the unit is polled (communicating with the fire on when commanded by the panel.The NP-200 Series offers pED l) nk when i alarm. tures and performance that represent the latest in smoke detector <br /> technology. <br /> • Low standby current <br /> MECHANICALS: Detector Sensitivity Test <br /> • Sealed against back pressure Each detector can have its sensitivity tested(required per NFPA 72, <br /> • SEMS screws for wiring of the separate base Chapter 14 on Inspection, Testing and Maintenance)when installed/ <br /> connected to an FireWarden Series addressable fire alarm control <br /> • Designed for direct-surface or electrical-box mounting panel. The results of the sensitivity test can be printed for record <br /> • Plugs into separate base for ease of installation and maintenance keeping. <br /> DN-60979:B•7/1/2019—Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.