Laserfiche WebLink
. . <br /> • <br /> POTTER BELLSPBA- <br /> The Symbol of Protection AC&PDC-DC <br /> Features <br /> • Listed for indoor and outdoor use <br /> • Outdoor use requires BBK-1 or HC-BB weatherproof back box . <br /> • Indoor use mounts directly to standard 4"box r <br /> • Low current draw <br /> • High dB output <br /> t <br /> • AC and DC models <br /> . . 0 <br /> • DC models are motor driven,polarized,and have built in <br /> transient protection for supervised alarm circuits <br /> • Available in 6",8"and 10"sizes <br /> 45 4400 <br /> APPROVED 1 <br /> *ULC on PDC-DC Only <br /> **FM on PBA-AC Only <br /> Description Technical Specifications <br /> These vibrating type bells are designed for use as fire or general i�;,,,e,,,,,,,,, 6'(150mm),8"(200mm)and 10-(250mm) <br /> signaling devices.They have low power consumption and high decibel Cover:Steel Finish:Red Powder Coat <br /> ratings.The unit mounts on a standard 4"(101mm)square electrical Base:non-corrosive composite material <br /> box for indoor use or on a model BBK-1 or HC-BB weatherproof Enclosure All parts have corrosion resistant finishes <br /> backbox for outdoor applications.Weatherproof backbox model BBK- Model BBK-1 or HC-BB weatherproof backbox(optional) <br /> 1 or HC-BB,Stock No. 1500001. 24VAC <br /> Voltages Available 120VAC <br /> 12VDC(10.2 to 15.6)Polarized <br /> Notes 24VDC(20.4 to 31.2)Polarized <br /> 1. Minimum dB ratings are calculated from integrated sound pressure Indoor or outdoor use(See Note 1) <br /> measurements made at Underwriters Laboratories as specified in Environmental -40°to 150°F(-40°to 66°C) <br /> Limitations <br /> UL Standard 464. UL temperature range is-30°to 150°F(-34°to (Outdoor use requires weatherproof backbox.) <br /> 66°C) AC Bells-4 No.18 AWG stranded wires <br /> Termination DC Bells-18 AWG stranded wire <br /> 2. Typical dB ratings are calculated from measurements made with a , <br /> conventional sound level meter and are indicative of output levels Service Use NFPA 13,72,local AHJ <br /> in an actual installation. <br /> *Specifications subject to change without notice. <br /> 3. ULC only applies to PDC-DC bells. <br /> Size inches Voltage Model Stock Current Typical dB at Minimum dB at A WA R N I N G <br /> (mm) Number Number (Max.) 1011.(3m)(2) 10 ft.(3m)(1) <br /> 6(150) 12VDC PDC-6-12 1750500 200mA 96 76 • Installation must be perfomed by qualified personnel and in accordance with all <br /> 8(200) 12VDC PDC-8-12 1750502 .200mA 96 77 national and local codes and ordinances. <br /> • Shock hazard.Disconnect power source before servicing.Serious injury or death <br /> 10(250) 12VDC' I'DC-10-12 1750504 .200mA 96 78 could result. <br /> 6(150) 24VDC PDC-6-24 1750501 .20mA 95 77 • Risk of explosion.Not for use in hazardous locations.Serious injury or death <br /> 8(200) 24VDC PDC-8-24 1750503 20mA 83 79 could result. <br /> 10(250) 24VDC I PDC-10-24 1 1750505 20mA 85 80 <br /> 6(150) 24VAC 1'BA246 t 1806024* .17A 91 78 A WA R N I N G <br /> 8(200) 24VAC PB.A248 1808024* .17A 94 77 <br /> 10(250) 24VAC PBA2410 1810024* .17A 94 78 In outdoor or wet installations,hell must he mounted with weatherproof backbox. <br /> 6(I50) 120VAC PBA1206 1806120• 05A 92 83 BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof <br /> R(200) 120VAC PBA1208 1R08120* OSA 99 enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an <br /> electrical hazard. <br /> 10(250) 120VAC PBA12010 1810120* .05A 99 86 <br /> All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. <br /> Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com <br /> 5400777-REV A • 12/20 PAGE 1 OF 2 <br />