Specifications — (continued) Minimum Control Unit Configuration <br /> Intelligent Addressable Device Loop A. Intelligent Signaling Line Circuit: <br /> MPC-6000 utilizes the advanced X-1 protocol for The main termination board has addressable-loop <br /> the detection circuit. The X-1 loop features include interface circuitry supporting one (1) SLC loop. <br /> SureWireTM technology, providing 252 input-and- Devices are polarity insensitive, and can operate on <br /> output addresses, polarity insensitivity, response untwisted, unshielded wire. <br /> time under 3 seconds, and retrofit installations using B. Notification Appliance Circuits: <br /> almost any type of wire(i.e.—shielded,non- <br /> shielded, twisted, etc.) The base panel has four(4) independent NACs. <br /> Abort Station Each circuit can be configured to give continuous <br /> output, or one (1) of five (5) sounding patterns. <br /> Model AW-1 Abort Station employs a momentary, NACs can be configured as: two (2) 'Class A— <br /> normally closed contact'Dead Man'type push- Style Z' or four (4) 'Class B — `Style Y.' <br /> button switch,which—while held in—prevents C. Dry Contacts: <br /> discharge of the clean agent. Upon release of the Three (3) programmable 'Form C' dry-contact relays <br /> push button, the Sinorixlm Engineered Fire- <br /> Suppression System will follow the sequence of are provided. One (1)additional 'Form C dry- <br /> events as programmed in the releasing panel, contact relay is provided that activates only on <br /> ultimately resulting in the release of the Sinorix Trouble events. This relay operates in Fail /Safe <br /> agent. mode in order to activate if there is a system power <br /> failure. <br /> Releasing Module D. Power Supply: <br /> Model MPC-REL provides two(2)releasing circuits The power-supply component provides all operating <br /> and four(4)open-collector outputs. power to the Model MPC-6000 panel for Standby <br /> Manual Release Station and Alarm conditions. <br /> The basic,standard model for the Manual Release Optional Control Unit Configuration <br /> Station is the double-action Model MH-501,which <br /> contains one normally open contact. Model MH-501 A. MPC-DACT Module: <br /> has a rating of 120VAC for connection to other <br /> systems. Model MH-501 is `dual-action' type. The Model MPC-DACT provides a dual-line, <br /> digital-alarm communicator transmitter that is <br /> Hence, it is necessary to operate the `push-in'tab <br /> first to provide access to the 'pull-down' lever, programmable, via the control panel or CIS-4 <br /> which—when operated—locks in position after configurationogrammable tool. <br /> releasing a spring-loaded contact switch to effect Model MPC-DACT is compatible with the following <br /> actuation of the release circuit. formats: <br /> • SIA DCS 8 <br /> Model MH-501 is constructed of durable, molded • SIA DCS 20 <br /> polycarbonate material, matte-finished in red with • Ademco Contact ID <br /> raised lettering in white. Restoring the system to • 4/2 1400 Hz <br /> normal can only be accomplished by opening the • 4/2 2300 Hz <br /> cover of the hinged housing with a special tool, • 3/1 1400 Hz <br /> • <br /> and then closing and locking its cover. 3/1 2300 Hz <br /> Model MH-501 is constructed with a molded B. City Tie: <br /> housing, fitted with a 'pull-down' lever and a `push- The main board supports a city-tie module that <br /> in' tab. The body of Model MH-501is hinged to a transmits local energy and reversed polarity. <br /> back-plate assembly, which is locked with a <br /> socket-head screw. <br /> 3I0) <br />