My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11031 19TH AVE SE 2024-02-28
>
Address Records
>
19TH AVE SE
>
11031
>
11031 19TH AVE SE 2024-02-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:18:56 PM
Creation date
2/14/2024 10:10:34 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
11031
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
17. Manufactures Specification - Important to follow the manufactures specification El El El <br /> on the correct testing of the device. (Incorrect testing can damage devices) <br /> Manual Fire Alarm Box(Pull Stations): <br /> PASS FAIL N/A <br /> 18. 100%Activation - 100%of Manual Fire Alarm Box(Pull Stations) provided shall be El El El <br /> tested by physical activation. <br /> 19. Location - Manual fire alarm boxes shall be located as follows: El El El <br /> • At a conspicuous, unobstructed, and assessable location. <br /> • Within 60 inches of exit doorway openings. <br /> • Mounted between 42 to 48 inches above the floor. <br /> 20 Addressable-Verify that upon activation of a manual fire alarm box the alarm El El El <br /> signal to the main fire alarm panel is correctly addressed with an accurate <br /> description. <br /> 21. Color- Manual fire alarm boxes shall be red in colors on a background of El El El <br /> contrasting color. <br /> Other Initiation Devices: <br /> PASS FAIL N/A <br /> 22. Other Devices-Combination Detector, Electrical Conductivity Heat Detector, Fire- El El El <br /> Gas Detector, Flame Detector, Pneumatic Rate-of-Rise Tubing Heat Detector, <br /> Projected Beam-Type Detector, Radiant Energy-Sensing Fire Detector, Rate <br /> Compensation Detector, Spark/Ember Detector, Spot-Type Detector shall follow <br /> the manufactures specification on the correct testing of that device. <br /> Step 8: Electrically Locking and/or Self-Closing PASS FAIL N/A <br /> Doors <br /> Door Releases: <br /> 1. Magnetic Door Hold -Verify that all Magnetic Door Hold-Open Release Devices El El El <br /> work when the system is in alarm.The doors shall close completely and latch. <br /> Electrically Locked Doors: <br /> PASS FAIL N/A <br /> 2. Electrically Locked Doors- Electrically locked doors that are part of the required <br /> means or egress shall comply with the following: <br /> • Unlock immediately upon loss of power. <br /> • Unlock upon activation of the fire alarm system and remain unlocked until <br /> the fire alarm condition is manually reset. <br /> • Unlock upon activation of the automatic sprinkler system. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 1 Page 8 <br />