My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-41 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-41
>
3003 W CASINO RD BLDG 40-41 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 8:04:05 AM
Creation date
2/14/2024 10:13:36 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-41
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*SPRINKLER VALVE WATERFLOW ALARM <br /> MONITORING AND WATERFLOW ISOLATION EIRE ALARM ABBREVIATIONS LEGEND <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION <br /> F_ WATERFLOWSEE SHEET ETA FOR SYMBOLS AND ABBREVIATIONS. <br /> PRESSURE SWITCH ALT SECONDARY OR ALTERNATE ELEVATOR RECALL NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> WITH BUILT—IN BEAM DET BEAM DETECTOR OS&Y OUTSIDE SCREW AND YOKE VAVLE O E N E RA E NOTES <br /> RETARD/DELAY, CDR COMPUTER/NETWORK/DATA/IDF ROOM PD PUMP DISCHARGE VALVE <br /> WFSR—F A COL COLUMN PH PENTHOUSE 1. ELECTRICAL CONTRACTOR SHALL INSTALL <br /> POTTER <br /> # COMM FAIL COMMUNICATION FAILURE PIV POST INDICATOR VALVE ENCLOSURE(S) AND POWER. <br /> (ALARM) CTRL CONTROL POWER FAIL FACP POWER FAILURE <br /> 1 CW CATWALK PREACT PREACTION SYSTEM 2. SPRINKLER RISER PIPING CONFIGURATION SHOWN IS <br /> DMPR DAMPER PRI PRIMARY DIAGRAMMATIC AND DOES NOT NECESSARILY <br /> DD DUCT SMOKE DETECTOR PS PUMP SUPPLY VALVE REPRESENT ANY SPECIFIC INSTALLATION. <br /> DIESEL DIESEL PWR POWER <br /> J FP FIRE PUMP RF ROOF CELLULAR COMMUNICATOR EQUIPMENT REPRESENTED <br /> TO ELEC ELECTRICAL; ELECTRICAL ROOM PLY RELAY ON THIS SHEET IS OF A SPECIFIC, APPROVED, <br /> MOTOR AGONG ELEV ELEVATOR SEC SECTION VALVE MANUFACTURER AND MODEL. INSTALLATION WILL VARY <br /> WATER PRESSURE GAUGE _ _ J EPP EXCESS PRESSURE PUMP SHUNT SHUNT TRIP DEPENDING ON APPROVED FINAL EQUIPMENT <br /> (SYSTEM PRESSURE) FACP FIRE ALARM CONTROL PANEL SMK SMOKE DETECTOR SELECTIONS. DETAILS AND CONSTRUCTION NOTES <br /> ALARM LINE 1 WATERFLOW ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR STL STALL SHALL APPLY TO ANY EQUIPMENT SELECTED. <br /> ISOLATION ISOLATION FLR FLOOR STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE ® <br /> (OPEN) VALVE, g TAMPER SWITCH, FM FIRE MAIN VALVE SUPER SUPPRESSION THIS SPECIFIC EQUIPMENT IS OPTIONAL AND MAY NOT <br /> APOLLO POTTER #RBVS HEAT HEAT DETECTOR SUPV SUPERVISORY NECESSARILY BE REQUIRED. 24VDC POWER MAY BE <br /> BY—PASS LINE #94A-103-27 (SUPERVISORY) INTDEV INTERFACE DEVICE, MONITORING OR CONTROL SV SPRINKLER VALVE DIRECTLY FED FROM THE BUILDING FACP TO THE <br /> L — — — — — ISO ISOLATION VALVE TAMPER TAMPER SWITCH CELLULAR COMMUNICATOR PANEL FOR SPECIFIC <br /> KITCHEN KITCHEN TL300 TL300 TYCO COMMUNICATION DEVICE EQUIPMENT SHOWN. <br /> L BATT LOW BATTERY TRBL TROUBLE <br /> L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) UV UNIT VALVE 5. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> CHECK VALVE RETARD LEY LOBBY VLV VALVE WORKMANLIKE MANNER. <br /> ° CHAMBER LRD LOW RATE DISCHARGE WF WATERFLOW SWITCH <br /> WATER PRESSURE GAUGE CHECK DRAIN MAN PULL MANUAL PULL STATION ZN ZONE 6. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> VALVE MECH MECHANICAL ROOM <br /> (SUPPLY PRESSURE) OPEN (CLOSED) 7. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> ® — A J CONSTRUCTION CONSTRUCTION NOTES (CONT.)OS&Y TAMPER 8. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL <br /> SWITCH WATER BY—PASS TEST [q::::- PROVIDE LINE SIZE BALL VALVE WITH LOCKABLE AND CELLULAR ENCLOSURES SHALL BE IN <br /> (SUPERVISORY) VALVE (CLOSED) STRAINER HANDLE, TYPE AS NOTED, ON ALARM LINE UPSTREAM ACCORDANCE WITH MANUFACTURER'S <br /> DRIP OF ALARM SWITCH. FIELD VERIFY CORRECT SIZE. INSTRUCTIONS. <br /> IF,la CUP COMM & SIGNAL (PHONE & TRBL CKT) REFERENCE DRAWINGS <br /> LD PROVIDE TAMPER SWITCH ON ISOLATION VALVE ASFIRE ALARM CELL. MONITORED BY JCI AND SHOWN.CONTROL COMM. SIGNAL SENT TO CENTRALl ONSTRUCTION NOTES <br /> PANEL ENL. BOEING FIRE DEPARTMENT 1WVIDE WATERFLOW PRESSURE SWITCH WITH ADJUSTABLE <br /> DELAY. PROVIDE CELLULAR DIALER, COMPATIBLE WITH AT&T <br /> OS&Y VALVE (EACH) <br /> *TWO SEPARATE PATHWAYS FOR CELLULAR SERVICE, AND MOUNT ADJACENT TO THE <br /> CONTROL (OPEN) COMM AND POWER, AS SHOWN. 12, CONFIRM SINGLE ISOLATION VALVE IS INSTALLED ON BUILDING FACP. CONFIGURE DIALER TO PROVIDE SOLE <br /> CHECK 24VDC POWER WATERFLOW SENSING LINE, WHERE EXISTING PATH COMMUNICATION. <br /> VALVE FIRE ALARM CABLING INSTALLATIONS HAVE MORE THAN ONE (1) VALVE, <br /> HORNS BELLS COORDINATE REMOVAL OF ADDITIONAL VALVE(S) WITH PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> SMOKE DETECTOR, ®� BOEING CONSTRUCTION MANAGER. FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> PULL STATION, WATER & STROBES ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> *NOTE: DRAIN FLOW & TAMPER 13. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> WATER SUPPLY PIPE SWITCHES INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. BUILDING EACH. <br /> LIMIT OF ONE (1) ISOLATION <br /> VALVE ON ALARM SENSING LINE. <br /> 3 PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH SPRINKLER RISER PRESSURE SWITCH WZDELAY DETAIL FIRE ALARM SYSTEM SIGNAL- AND COMMUNICATIONS OVERVIEW POWER SUPPLY. PROVIDE"POW R AND WIRE AS SHOW. <br /> SCALE: NONE E511 SCALE: NONE E511 MAINTAIN MANUFACTURER REQUIRED 1/4" SEPARATION <br /> BETWEEN POWER AND COMMUNICATION WIRING. <br /> ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> BACKGROUND, THAT READS: "FIRE ALARM CELLULAR <br /> DIALER" <br /> A PEM POWER CABLE STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL WHERE INDICATED 5 PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> (SUPPLIED WITH PEM ON DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. STRENGTH IN ACCORDANCE WITH DETAIL FIELD <br /> S. INSTALL <br /> STEP 2 IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20F RADIUS CONDUIT AND EXTENDED ANTENNA CABLE AS NECESSARY <br /> TO IDENTIFY LOCATIONS) SUITABLE FOR INSTALLATION OF REMOTE EXTERNAL CELLULAR ANTENNA. TO REMOTE MOUNT ANTENNA IF COVERAGE IS NOT <br /> COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR APPROVAL SUITABLE AT FRCP LOCATION. UPDATE BOM WITH <br /> 33/4"C — 2#14THHN,1#14G PRIOR TO ROUGH—IN AND SKIP TO STEP 4. SELECTED CABLE LENGTH AND PROVIDE REDLINES TO <br /> 0 4BOEING ENGINEER. <br /> STEP 3: PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE WITH BOEING AND SPACE USERS FOR <br /> ® FACP EVT—FA-40-41 TG—PEM L POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. IF ANTENNA IS REQUIRED FOR ALTERNATE © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> (BY FIRE ALARM VENDOR) DO, U__> LOCATION GO TO NEXT STEP, OTHERWISE SKIP TO STEP 5. WHITE LETTERING, RED BACKGROUND, THAT READS: "FIRE <br /> L— TG—7 ES STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE ALARM CELLULAR ANTENNA" <br /> ——J GRN 4 7 FROM CELLULAR COMMUNICATOR PANEL TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED 7 POST COMMUNICATOR SETTINGS AND CELLUAR PHONE <br /> R WITHIN 20FT OF EACH OTHER. NUMBER INSIDE CELL ENCLOSURE. PROVIDE PRINTED <br /> 3 STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR PANEL LABEL, HANDWRITTEN INFORMATION IS NOT ACCEPTABLE. <br /> ®❑ T FROM BUILDING FACP. PROVIDE 24VDC:12VDC VOLTAGE REGULATOR AS NECESSARY. PROVIDE SETTINGS AND CELLULAR INFORMATION TO <br /> STEP 6: PROVIDE REQUIRED SET—UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER BOEING ENGINEER. <br /> DC STC2 STC1TRIP BATT AC THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A SOLE ® PROVIDE PHENOLIC LABEL, INSTALL AND CENTER ON <br /> 2 1 2 3 4 5 6 1 2 3 1 2 G PATH FOR FIRE COMMUNICATIONS. UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> 0 0� 0 STEP 7: WHERE CELLULAR COMMUNICATOR PANEL IS INSTALLED REMOTELY OF BUILDING FACP, PROVIDE CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> R� ADDRESSABLE SMOKE DETECTION, MONITORED BY BUILDING FACP, AT THE CELLULAR COMMUNICATOR PANEL. LETTERING AND RED BACKGROUND. <br /> RED EOL(AS NEEDED) <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURER'S SPECIFICATIONS AND LOCAL AHJ <br /> ORDINANCES. <br /> (1) 2 - (1) PHONE CABLE, <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE <br /> (1) 2 CONDUCTOR FPL OR <br /> / APPROVED EQUAL SCALE: NONE E`51111 <br /> SCALE: NG <br /> FRE SYSTEM COMMUNICATIONS DETAILNE ,E26o E511 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY ORA ATE SUBTITLE CURRENT REVISION I SYMBOL DATE <br /> A EVERETT FIRE PANEL REPLACEMENT— XX W2640474 SAZAN/ZO 02.24.23 THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM DETAILS 29454351 B 06.20.23 <br /> SPECIFICATION IS APPROVED SHEET SEQUENCE NO. <br /> Q�BOE//VGN EVERETT FIRE PANEL REPLACEMENT E511 <br /> B SHOP DRAWINGS 29454351 AGOW/JS 06 1923 APPRovEo Br DEPT. DATE <br /> CHECKED <br /> �.e L;ame APPROVED BUILDING 40-041 <br /> APPROVED ELECTRICAL MASTER EVERETT, WA. DWG NO. 40-041—E511 <br />
The URL can be used to link to this page
Your browser does not support the video tag.