My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-41 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-41
>
3003 W CASINO RD BLDG 40-41 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 8:04:05 AM
Creation date
2/14/2024 10:13:36 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-41
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SmartOne® or Kidde <br /> Addressable Relay Output Device Fire Systems <br /> K-76-018 Effective: May 2020 <br /> FEATURES <br /> • Full-Digital Communications <br /> • Addressable Control Point <br /> • Unpowered,SPDT Relay Contacts <br /> • Control-by-Event And/or By Time Operation <br /> • Status Indicator <br /> • Unique Internal Supervision <br /> UL Listed <br /> • FM Approved °` '' ' ="JJ <br /> • CSFM Approved <br /> DESCRIPTION <br /> The SmartOne® Addressable Relay Output Device (AO) is an <br /> SPECIFICATIONS <br /> addressable output module for control of auxiliary equipment Input Voltage: 24 VDC(nominal) <br /> such as air handlers, door release and elevator recall. <br /> The AO connects directly to a compatible control unit's Signaling Standby Current: 500 NA,Typical <br /> Line Circuit(SLC) and contains a SPDT relay to control auxiliary Alarm Current: 500 NA,Typical <br /> equipment. All of the electronics are contained in a small high- <br /> impact polymer case. This creates a small and durable device for Contact Ratings: <br /> installation. A silicone-free module is available for applications Resistive: 2 A @ 30 VDC <br /> where silicone is not desired.The AO can be mounted in a North Inductive(Motor Control): 1.0 A @ 30 VDC,0.60 PF <br /> American 1-1/2-in. (64 mm) deep 1-gang box, or standard 4-in. 0.6 A @ 120 VAC,0.35 PF <br /> square box 1-1/2-in. (38 mm)deep with a cover. Pilot Duty: 0.6 A @ 30 VDC,0.35 PF <br /> FIELD PROGRAMMING Operating Environment: -31 to 151°F(-35 to 66°C)at <br /> The AO is field programmable with a unique 3-digit address and a 0 to 95%RH <br /> 40-character owner location message. The AO relay may be set <br /> or reset on command from the control unit. In addition to combi- <br /> national-logic programming that utilizes system inputs (i.e., LED Pulse Modes: <br /> events) to activate this device, the unit may be programmed for Normal: 9 second interval <br /> real-time clock operation. The real-time clock programming Trouble: LED is off <br /> permits the AO to be activated and deactivated by the time of day, Alarm: 2 second interval <br /> calendar date and day of the week. <br /> Wire Sizes: 14, 16, 18 AWG Acceptable <br /> SUPERVISION <br /> The AO is continuously monitored for: Dimensions: 2.3"x 1.8"x 0.8"nominal <br /> • Internal power supply voltages Shipping Weight: 5.1 oz(145 g) <br /> • Faulty entering of data into AO's memory <br /> • Relay state equals command state COMPATIBLE CONTROL UNITS <br /> An internal set of relay contacts provides a feedback signal that Fire Alarm Control Current Legacy <br /> confirms the activation of the addressable relay output. If the Unit(FACU)Type Product Product <br /> relay fails to operate at the appropriate time, the device transmits <br /> a trouble report for display by the control unit. Single Loop ARIES°-SLX ARIES <br /> FenwaINET T" 6000 <br /> STATUS LED PEGAsysTI <br /> A status LED is mounted on the unit. FenwaINET 2000 <br /> ORDERING INFORMATION Multiple Loop ARIES®-MLX ARIES NETLink <br /> FenwaINET 8000-ML <br /> AO Control Module 70-408004-001 PEGAsys* <br /> AO Control Module,non-silicone 70-408014-001 FenwaINET 2000 <br /> *FACUs running software revision 82.4 are compatibility-tested but <br /> SmartOne and ARIES are registered trademarks of Kidde-Fenwal,Inc.,or its not agency listed with the device(s)in this data sheet. <br /> parents,subsidiaries or affiliates. <br /> This literature is provided for informational purposes only.KIDDE-FENWAL,INC.believes this data to be accurate,but it is published and presented without any <br /> guarantee or warranty whatsoever.KIDDE-FENWAL,INC.assumes no responsibility for the product's suitability fora particular application.The fire suppression system <br /> design,installation,maintenance,service and troubleshooting must be performed by trained,authorized Kidde Fire Systems distributors for the product to work correctly. <br /> If you need more information on this product,or if you have a particular problem or question,contact: <br /> KIDDE-FENWAL,INC.,Ashland,MA 01721 USA,Telephone:(508)881-2000. <br /> EXPORT INFORMATION(USA) Kidde Fire Systems400 Main Street <br /> Kidde K-76-018 Rev AB Jurisdiction:EAR Ashland,MA 01721 <br /> ©2020 Kidde-Fenwal,Inc. Classification:EAR99 Ph:508.881.2000 <br /> Fire Systems This document contains technical Fax:508.881.8920 <br /> data subject to the EAR. www.kiddefiresystems.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.