My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4035 SMITH AVE 2024-02-29
>
Address Records
>
SMITH AVE
>
4035
>
4035 SMITH AVE 2024-02-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 2:58:14 PM
Creation date
2/14/2024 10:18:55 AM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
4035
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Electronics and operational controls fully enclosed in a • Waterflow (silenceable/non-silenceable) operation. <br /> lockable cabinet capable of housing up to 12 AH batter- • Supervisory (standard/auto-reset) operation. <br /> ies. • Remote switch for Reset, Drill, Silence, Acknowledge. <br /> • Optional LED-10 Series Remote Annunciators operate • Critical and Noncritical Process Monitoring (standard/ <br /> off serial two-wire EIA-485 interface. auto-reset). <br /> • Optional contact-by-zone module and printer interface All circuits are power-limited and fully supervised. They <br /> for on-or off-line printing. allow up to 100 ohms of line resistance and allow for use of <br /> • 230 VAC, 50 Hz international version available. 12 to 18 AWG wire. <br /> REMOTE SITE UPLOAD/DOWNLOAD NOTIFICATION APPLIANCE CIRCUITS <br /> The MS-5210UD may be downloaded or uploaded(requires • Two Style Y(Class B)@ 3.0 amps each. Use the CAC- <br /> panel software revision #MS52103.0 or greater) without 10F Class A Converter Module to convert all Class B <br /> compromising the system fire protection at the protected NAC's and IDC's to Class A. <br /> premises. • Option module adds two Style Z (Class A) NACs @ 1.5 <br /> • Download system programming. amps each. <br /> • Upload key system information: • All circuits are fully power-limited and meet the new UL <br /> ✓Current system status, history+walk test files. power-limiting requirements effective May 1, 1995,using <br /> ./Zone, AC line, NAC1, 2, 3 and 4, resettable power fuseless technology. <br /> and battery voltages. AUXILIARY OUTPUTS <br /> ✓System programming. <br /> • Upload or download within one minute without affecting • Resettable four-wire smoke detector power @ 500 mA. <br /> normal fire panel functions. • Non-resettable power @ 500 mA. <br /> • Multiple security techniques. • Two fully programmable Form-A/B relays. <br /> • Requires PK-521 OUD programming kit,which works with • Option module adds two fully programmable Form-C <br /> most Hayes-compatible modems(consult factory for list- relays. <br /> ing). COMPATIBLE DEVICES, EIA-485 PORT <br /> SPECIFICATIONS LED-101M: EIA-485 Interface Module. Provides MS- <br /> Single PC board design using Surface Mount Technology 521OUD with EIA-485 output, capable of supporting up to <br /> (SMT). Two modular telephone jacks for connection to 32 compatible EIA-485 devices (listed below). <br /> RJ31X/Modules. LED-10 Series: LED-type fire annunciators capable of <br /> AC Power displaying Alarm(red)and Trouble(yellow)LEDs for all ten <br /> • 120 VAC, 50/60 Hz, 2.3 amps. Initiating Device Circuits (IDCs). NOTE: For Canadian <br /> • 230 VAC, 50 Hz, 1.2 amps ("E" suffix). Supervisory Service, use LED-10LS2 only. <br /> • Wire size: minimum 14 AWG with 600-volt insulation. AFM-16AF: LED-type fire annunciator capable of pro- <br /> Built-in brownout circuitry. viding up to 16 zones of Alarm(red)annunciation and com- <br /> • Built-in voltmeter. mon system trouble LED. Mounts to 4-gang electrical box <br /> Communicator ONLY. <br /> • One line-active indicator for each of two phone lines. LDM Series: Lamp Driver Module series for use with <br /> • "Kiss-Off' signal LED. custom graphic annunciators. <br /> • Dual "low telephone voltage detect" circuitry. ACM-8RF: Remote Form-C relay module. Provides eight <br /> • Programmable event codes per each format. mappable Form-C relays driven by EIA-485 for contact-by- <br /> zone capability(two minimum required for contact-by-zone). <br /> • Up to 100 transmitted events/messages. Each requires ABS-8RF for mounting. <br /> • Selectable/deselectable transmissions of 100 events. NOTE: For more detailed information on Compatible EIA-485 <br /> Communication Formats Devices for use with the MS-5210UD,please refer to the LED-10, <br /> Express and Ademco Contact ID formats allow complete AFM/AFM-X,LDM or ACM-8RF data sheets, document numbers <br /> transaction to be communicated in under five seconds. DF-51500, DF-51465, DF-51384, and DF-51555 respectively. <br /> • Ademco Contact ID. CABINET SPECIFICATIONS <br /> • 20 PPS, 3+1 standard and expanded. The cabinet is red with a dark blue overlay. Knockouts on <br /> • 20 PPS, 4+1 standard and expanded. the top, sides, and back provide ease of wire entry. The <br /> • 20 PPS, 4+2 standard and expanded. cabinet can be surface or semi-flush mounted and is com- <br /> • 4+1 and 4+2 Ademco Express. pact in design. <br /> INITIATING DEVICE CIRCUITS (ZONES) Dimensions: <br /> The MS-521OUD includes ten programmable Class B Initi- Door: 17.11" high x 14.71"wide <br /> ating Device Circuits (zones). Use the CAC-1 OF Class A (43.46 cm high x 37.36 cm wide). <br /> converter module to convert all Class B IDC's/NAC's to Backbox: 16.90" high x 14.50"wide x 4.50" deep <br /> Class A. (42.93 cm high x 36.83 cm wide x 11.43 cm <br /> Each zone may support two-wire smoke detectors. Pro- deep). <br /> gramming options include: Trim Ring: Part# TR-4-R, 20.020" high x 17.620"wide <br /> • Normally Open Contact devices (pull, heat). (50.85 cm high x 44.75 cm wide). <br /> • Four-wire smoke detectors. <br /> Page 2 of 3 — DF-51492•07/12/04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.