My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-86 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-86
>
3003 W CASINO RD BLDG 40-86 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 9:04:27 AM
Creation date
2/14/2024 11:09:15 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-86
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*SPRINKLER VALVE WATERFLOW ALARM <br /> MONITORING AND WATERFLOW ISOLATION FIRE ALARM ABBREVIATIONS LEGEND <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION <br /> F_ WATLRFLOWSEE SHEET EO FOR SYMBOLS AND ABBREVIATIONS. <br /> PRESSURE SWITCH ALT SECONDARY OR ALTERNATE ELEVATOR RECALL NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> WITH BUILT—IN BEAM DET BEAM DETECTOR OS&Y OUTSIDE SCREW AND YOKE VAVLE G F N F RA L N O T F S <br /> RETARD/DELAY, CDR COMPUTER/NETWORK/DATA/IDF ROOM PD PUMP DISCHARGE VALVE <br /> A COL COLUMN PH PENTHOUSE 1. ELECTRICAL CONTRACTOR SHALL INSTALL <br /> POTTER #WFSR—F <br /> COMM FAIL COMMUNICATION FAILURE PIV POST INDICATOR VALVE A ENCLOSURE(S) AND POWER. <br /> (ALARM) CTRL CONTROL POWER FAIL FACP POWER FAILURE <br /> 1 CW CATWALK PREACT PREACTION SYSTEM 2. SPRINKLER RISER PIPING CONFIGURATION SHOWN IS <br /> DMPR DAMPER PRI PRIMARY DIAGRAMMATIC AND DOES NOT NECESSARILY <br /> DD DUCT SMOKE DETECTOR PS PUMP SUPPLY VALVE REPRESENT ANY SPECIFIC INSTALLATION. <br /> DIESEL DIESEL PWR POWER <br /> J FP FIRE PUMP RF ROOF CELLULAR COMMUNICATOR EQUIPMENT REPRESENTED <br /> TO ELEC ELECTRICAL; ELECTRICAL ROOM PLY RELAY ON THIS SHEET IS OF A SPECIFIC, APPROVED, <br /> MOTOR AGONG ELEV ELEVATOR SEC SECTION VALVE MANUFACTURER AND MODEL. INSTALLATION WILL VARY <br /> WATER PRESSURE GAUGE _ _ J EPP EXCESS PRESSURE PUMP SHUNT SHUNT TRIP DEPENDING ON APPROVED FINAL EQUIPMENT <br /> (SYSTEM PRESSURE) FACP FIRE ALARM CONTROL PANEL SMK SMOKE DETECTOR SELECTIONS. DETAILS AND CONSTRUCTION NOTES <br /> ALARM LINE 1 WATERFLOW ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR STL STALL SHALL APPLY TO ANY EQUIPMENT SELECTED. <br /> ISOLATION ISOLATION FLR FLOOR STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE ® <br /> (OPEN) VALVE, 9 TAMPER SWITCH, FM FIRE MAIN VALVE SUPER SUPPRESSION THIS SPECIFIC EQUIPMENT IS OPTIONAL AND MAY NOT <br /> APOLLO POTTER #RBVS HEAT HEAT DETECTOR SUPV SUPERVISORY NECESSARILY BE REQUIRED. 24VDC POWER MAY BE <br /> #94A-103-27 (SUPERVISORY) INTDEV INTERFACE DEVICE, MONITORING OR CONTROL SV SPRINKLER VALVE DIRECTLY FED FROM THE BUILDING FACP TO THE <br /> BY—PASS LINE <br /> L — — — — — ISO ISOLATION VALVE TAMPER TAMPER SWITCH CELLULAR COMMUNICATOR PANEL FOR SPECIFIC <br /> KITCHEN KITCHEN TL300 TL300 TYCO COMMUNICATION DEVICE EQUIPMENT SHOWN. <br /> L BATT LOW BATTERY TRBL TROUBLE <br /> L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) UV UNIT VALVE 5. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> CHECK VALVE RETARD LBY LOBBY VLV VALVE WORKMANLIKE MANNER. <br /> ° CHAMBER LRD LOW RATE DISCHARGE WF WATERFLOW SWITCH <br /> WATER PRESSURE GAUGE CHECK DRAIN MAN PULL MANUAL PULL STATION ZN ZONE 6. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> VALVE MECH MECHANICAL ROOM <br /> (SUPPLY PRESSURE) OPEN (CLOSED) 7. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> ® — J CONSTRUCTION CONSTRUCTION NOTES (CONT.)OS&Y TAMPER 8. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL <br /> SWITCH WATER BY—PASS TEST PROVIDE LINE SIZE BALL VALVE WITH LOCKABLE AND CELLULAR ENCLOSURES SHALL BE IN <br /> (SUPERVISORY) VALVE (CLOSED) STRAINER HANDLE, TYPE AS NOTED, ON ALARM LINE UPSTREAM ACCORDANCE WITH MANUFACTURER'S <br /> DRIP OF ALARM SWITCH. FIELD VERIFY CORRECT SIZE. INSTRUCTIONS. <br /> IF,la CUPCOMM & SIGNAL (PHONE & TRBL CKT) REFERENCE DRAWINGS <br /> p 10 PROVIDE TAMPER SWITCH ON ISOLATION VALVE AS <br /> FIRE ALARM A CELL. MONITORED BY JCI AND SHOWN. <br /> CONTROL C COMM. SIGNAL SENT TO CENTRAL CONSTRUCTION NOTES <br /> PANEL T ENL. BOEING FIRE DEPARTMENT 1WVIDE WATERFLOW PRESSURE SWITCH WITH ADJUSTABLE <br /> DELAY. PROVIDE CELLULAR DIALER, COMPATIBLE WITH AT&T <br /> OS&Y VALVE (FACP) <br /> *TWO SEPARATE PATHWAYS FOR CELLULAR SERVICE, AND MOUNT ADJACENT TO THE <br /> CONTROL (OPEN) COMM AND POWER, AS SHOWN. 12. CONFIRM SINGLE ISOLATION VALVE IS INSTALLED ON BUILDING FACP. CONFIGURE DIALER TO PROVIDE SOLE <br /> CHECK �24VDC WATERFLOW SENSING LINE, WHERE EXISTING PATH COMMUNICATION. <br /> VALVE FIRE ALARM CABLING INSTALLATIONS HAVE MORE THAN ONE (1) VALVE, <br /> HORNS BELLS COORDINATE REMOVAL OF ADDITIONAL VALVE(S) WITH PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> S SMOKE DETECTOR, ®� BOEING CONSTRUCTION MANAGER. FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> PULL STATION, WATER & STROBES ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> *NOTE: DRAIN FLOW & TAMPER 13. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> WATER SUPPLY PIPE SWITCHES INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. BUILDING FACP. <br /> LIMIT OF ONE (1) ISOLATION <br /> VALVE ON ALARM SENSING LINE. <br /> 3 PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH SPRINKLER RISER PRESSURE SWITCH WZDELAY DETAIL FIRE ALARM SYSTEM SIGNAL- AND COMMUNICATIONS OVERVIEW POWER SUPPLY. PROVIDE"POW R AND WIRE AS SHOW. <br /> SCALE: NONE E507 SCALE: NONE E507 MAINTAIN MANUFACTURER REQUIRED 1/4" SEPARATION <br /> BETWEEN POWER AND COMMUNICATION WIRING. <br /> ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> BACKGROUND, THAT READS: "FIRE ALARM CELLULAR <br /> DIALER" <br /> 6 5 PEM POWER CABLE STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL WHERE INDICATED <br /> A (SUPPLIED WITH PE�)] ON DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> /r1111— <br /> ———— STRENGTH IN ACCORDANCE WITH DETAIL 4/E506. INSTALL <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS CONDUIT AND EXTENDED ANTENNA CABLE AS NECESSARY <br /> TO IDENTIFY LOCATIONS) SUITABLE FOR INSTALLATION OF REMOTE EXTERNAL CELLULAR ANTENNA. TO REMOTE MOUNT ANTENNA IF COVERAGE IS NOT <br /> — <br /> r� � � COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR APPROVAL SUITABLE AT FRCP LOCATION. UPDATE BOM WITH <br /> 33/4"C — 2#14THHN,1#14G PRIOR TO ROUGH—IN AND SKIP TO STEP 4. SELECTED CABLE LENGTH AND PROVIDE REDLINES TO <br /> (14 BOEING ENGINEER. <br /> STEP 3: PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE WITH BOEING AND SPACE USERS FOR <br /> ®FACP EVT—FA-40-86 TG-PEM L POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. IF ANTENNA IS REQUIRED FOR ALTERNATE © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> (BY FIRE ALARM VENDOR) DO, U__> LOCATION GO TO NEXT STEP, OTHERWISE SKIP TO STEP 5. WHITE LETTERING, RED BACKGROUND, THAT READS: "FIRE <br /> L— TG—7 ES STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE ALARM CELLULAR ANTENNA" <br /> ——J GRN 4 7 FROM CELLULAR COMMUNICATOR PANEL TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED 7 POST COMMUNICATOR SETTINGS AND CELLUAR PHONE <br /> R WITHIN 20FT OF EACH OTHER. NUMBER INSIDE CELL ENCLOSURE. PROVIDE PRINTED <br /> 3 STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR PANEL LABEL, HANDWRITTEN INFORMATION IS NOT ACCEPTABLE. <br /> L T FROM BUILDING FACP. PROVIDE 24VDC:12VDC VOLTAGE REGULATOR AS NECESSARY. PROVIDE SETTINGS AND CELLULAR INFORMATION TO <br /> STEP 6: PROVIDE REQUIRED SET—UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER BOEING ENGINEER. <br /> DC STC2 STC1TRIP BATT AC THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A SOLE ® PROVIDE PHENOLIC LABEL, INSTALL AND CENTER ON <br /> 2 1 2 3 4 5 6 1 2 3 Fl—21 G PATH FOR FIRE COMMUNICATIONS. UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> 0 0� STEP 7: WHERE CELLULAR COMMUNICATOR PANEL IS INSTALLED REMOTELY OF BUILDING FACP, PROVIDE CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> D� ADDRESSABLE SMOKE DETECTION, MONITORED BY BUILDING FACP, AT THE CELLULAR COMMUNICATOR PANEL. LETTERING AND RED BACKGROUND. <br /> RED EOL(AS NEEDED) <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURER'S SPECIFICATIONS AND LOCAL AHJ <br /> ORDINANCES. <br /> 3/4"C — (1) PHONE CABLE, <br /> (1) 2 CONDUCTOR FPL OR <br /> APPROVED EQUAL CELLULAR COMMUNICATOR INSTALLATION SEQUENCE 4 <br /> SCALE: NONE E`7 <br /> cARENGALARM SYSTEM COMMUNICATIONS DETAIL NE 1 E2613E567 owkel , <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY Z. OLSON 04.21.23 FIRE ALARM SYSTEM DETAILS 30390094 A 09.14.23 <br /> - EVERETT FIRE PANEL REPLACEMENT- IFC W2640474 SAZAN/ZO 04.21.23 THIS DESIGN AND/OR CMECKEO <br /> SPECIFICATION IS APPROVED Z.OLSON 04.21.23 sMEEr SEQUENCE Na. <br /> A SHOP DRAWINGS 30390094 AGOW/JS 09.14.23 Q�BOE//VG m APPROVED BY DEPT. DATE CN KRAUSE 04.21.23 TITLE EVERET FIRE PANEL REPLACEMENT E507 <br /> CHECKED <br /> ete L R�Den C. KRAUSE 04.21.23 BUILDING 40-086 <br /> ,���,� me APPROVED <br /> APPROVED ELECTRICAL EVERETT, WA. DWG No. 40-086—E507 <br />
The URL can be used to link to this page
Your browser does not support the video tag.