Laserfiche WebLink
LEGEND <br /> SEE SHEET EO FOR LEGEND AND ABBREVIATIONS <br /> Kidde 4W Main Street BILL OF MATERIALS <br /> Fire Systems PtAA ss 017221 NUM QTY PART # DESCRIPTION <br /> 2000 <br /> www.kiddefiresystems.conl 1 1 76-800100-001 ARIES NETLINK MULTI-LOOP CONTROL UNIT <br /> Aries N TII I k Power and Batter Calculation 2 1 76-800010-002 BACKPLANE PCB FOR ARIES NETLINK <br /> `�i y 3 1 76-800010-001 EXPANSION CARD CAGE FOR ARIES NETLINK <br /> 11-` ='' 4 1 76-800015-001 ARIES NETLINK MULTI-LOOP DACT CARD <br /> Enter Distributor lnformat)On:ALEXANDER GOW FIRE EQUIPMENT COMPANY 5 35 KS-PS PHOTO DETECTOR <br /> Name:KEVIN MULLEN 6 35 DS-SB STANDARD BASE FOR DS SERIES DETECTORS. <br /> Project Name:BOEING EVERETT 40-86 BLDG FIRE ALARM REPLACEMENT 7 1 84-330002-001 PULL STATION-ADDRESSABLE <br /> Service Request#: 8 38 70-610001-001 Al MONITOR MODULE N 0-N C <br /> Prepared By:KEVIN MULLEN 9 2 SLA1161 12V 44AH BATTERY <br /> 10 1 06-SS000689-1 RECORD STORAGE CABINET <br /> Description: <br /> 11 1 1000015 SSU-00500 - BATTERY CABINET <br /> 12 5 3008040 POTTER WIRELESS TRANSMITTERWTX-M RECEIVERWRX-R GENERAL NOTES <br /> 13 7 D4120 SYSTEM SENSOR DUCT DETECTOR <br /> Power Supply and Battery Size Calculation <br /> A ITotal Stand-By Current per System: 0.609 Amps <br /> B ITotal Alarm Current per System: 3.019 Amps <br /> C Enter Stand-By Hours: 46 Hour <br /> D Enter Alarm Time: 10 Minute <br /> E Ampere Hour Required((A"C)+(B'D)): 29.84 AH <br /> F Total Amp Hour Require(0criNtipq Factor 1.2): 36.00 AH Right-Click to Update.Print and <br /> G Battery Size Required Per System(two(2)batteries required): 36 AH Clear Battery CalcdatIM. PRIMARY POWER CONNECTIONS: <br /> H 2-Tiered Main or Expansion Enclosure,Max.15 Am s' 15 Amps AC POWER MUST BE PROVIDED TO THE CENTRAL CONTROL PANEL'S POWER <br /> Expansion Enclosures Required? YES SUPPLY USING #14 AWG FROM A DEDICATED 15 AMP BREAKER. <br /> J Number of Enclosure Main/Expansion)Required: 1 <br /> K Number of Power Management Unit PMU Board Required: 1 FIELD DEVICES: <br /> L INumber of Power Supply Unit P Required: 1 KIDDE RECOMMENDS THE USE OF #18 AWG MINIMUM WIRING AS THE <br /> E • CONNECTION CABLE BETWEEN THE RX/TX MODULE AND THE FIELD DEVICES. REFERENCE DRAWINGS <br /> Total Total END OF LINE DEVICES: <br /> Un it Unit Un It Unit <br /> Standby Standby Alarm Alarm ALL END OF LINE (EOL) DEVICES FOR SIGNAL CIRCUITS IS 10KO 1/2W. <br /> Item Enter Current Current Current Current FOR ADDRESSABLE CONTACT INPUTS IS 10KO 1/2W. <br /> Description1 140.1 with Keyboard/Display) 1 0.158 0.158 0.300 0.3001 <br /> 2 Digital Alarm Communicator Transmitter( Expansion Card Max.1 Per System) 1 0.024 0.024 0.037 0.03J CIRCUIT 1 CIRCUIT 1 <br /> 3 5jgqAPM Photoelectric Smoke Detector 35 0.000150 0.005250 0.000220 0.0077 HORN/STROBE HORN/STROBE <br /> 4 Contact Input Module AI's.WO 38 0.000580 0.022040 0.000580 0.02204i FIRST DEVICE LAST DEVICE <br /> 5 HIS Series Horty 15 0.000 0.000 0.163 2.44 <br /> 6 POTTER SIGNAL LINK BRIDGE WIRELESS SUPERVISORY SYSTEM 5 0.055 0.275 0.075 0.37 RS1:7 <br /> 7 A CELLULAR ALARM COMMUNICATOR 1 0.060 0.060 0.250 0.2 10K EOL RESISTOR <br /> 8 Power Management Unit P Board#1.Max.10.8 Ams 1 0.070 0.070 0.090 0. RS1:8 <br /> CIRCUIT 2 CIRCUIT 2 <br /> HORN/STROBE HORN/STROBE <br /> FIRST DEVICE LAST DEVICE CONSTRUCTION NOTES <br /> RS1:9 ® 10K EOL RESISTOR <br /> WTX-M-Transmitter WRX-R- Wireless Receiver RS1:10 <br /> _J ail <br /> 0 0 <br /> ® g o ® <br /> CIRCUIT 3 CIRCUIT 3 <br /> HORN/STROBE HORN/STROBE <br /> R FIRST DEVICE LAST DEVICE <br /> RS1:9 10K EOL RESISTOR <br /> RS1:10 <br /> (] +� a° <br /> + DUCT DETECTOR <br /> 120VAC (PROVIDED BY OTHERS) <br /> 0 0 ® o <br /> a.TrER.o°MPeR.MEHT am.,..,.. •o o � o <br /> .µ.Lro. <br /> o G®" <br /> 0 0 •e•eo® <br /> �R-ED,FANSLBFFE a[ur UNDER <br /> '.'IT" V__� <br /> CONNECTS—CONDITNO TERMI-ANDTME O INTf <br /> WINl�oN CARORmE TR.0 DLA o 0 0 o O v O <br /> THE FIRE PANEL ES ATRWBLE ON o t <br /> TO HVAC UNIT SHUTDOWN , <br /> SLC CIRCUIT TO <br /> NEXT DEVICE <br /> SLC CIRCUIT FROM <br /> PREVIOUS DEVICE GLO, � , <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A SUBTITLE CURRENT REVISION SYMBOL DATE <br /> AccESGN AND/OR UTY Z. CKEU oa.z,.z3 FIRE ALARM SYSTEM DETAILS 30390094 A 09.14.23 <br /> - EVERETT FIRE PANEL REPLACEMENT- IFC W2640474 SAZAN/ZO 04.21.23 Trill DESIGN PRO Z.OLSD <br /> SPEaFlCATION IS APPROVED Z.OLSON 04.21.23 sHEEr SEQUENCE Na. <br /> A SHOP DRAWINGS 303e00e4 AGow/ds 00.14.23 Q�BOE APPROVED BY DEPT. DATE CN KRAUSE oa.2,.23 TITLE EVERETTFIRE PANEL REPLACEMENT E507-2 <br /> CHECKEC. D <br /> °dL APPROVEDE 04.21.23 BUILDING 40-086 <br /> APPROVED ELECTRICAL EVERETT, WA. DWG NO. 40-086-E507-2 <br />