My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-86 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-86
>
3003 W CASINO RD BLDG 40-86 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 9:04:27 AM
Creation date
2/14/2024 11:09:15 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-86
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER SignaLinkT" Bridge <br /> The symbol of Protection Wireless Supervisory System <br /> 1 <br /> Devices do not need to be re-paired when batteries are replaced or if the unit is powered down. <br /> If a WR must be replaced,the wireless Setup tool must be used to remove the MAC address of the old device from the system.Then the new device <br /> can be paired using either the Setup tool or the cover tamper switch. <br /> Installation <br /> Installation shall be performed by qualified personnel and in accordance with all local and national codes and ordinances and the approval of the local <br /> AHJ. <br /> A CAUTION <br /> 7=unicafion <br /> s shall not be used as the primary initiating device to activate water or agent suppression systems.Wireless devices may experience <br /> or interferenceissues which could result in an unintended discharge or a failure to discharge. <br /> 1 <br /> Maximum line of site communication is approximately 800 feet between devices.Metal objects can greatly reduce signal strength.A chain link <br /> fence can almost completely block a signal if the fence is too close to the transmitter,repeater or receiver.Metal shelving,walls with metal framing, <br /> metal doors,windows with wired glass,vehicles,all have an effect on the ability of the wireless signal to pass through. <br /> For best transmission/reception of wireless communication,it may help to attempt to install the Transmitter in a position so that it is not completely <br /> obstructed from metal.Rotating the Transmitter enclosure so that it can"see"around the metal Potter device,pipe,valve,etc.may help communication. <br /> When mounting the repeater to a post,it may be necessary to rotate the Repeater on the post to achieve best signal reception/transmission. <br /> WTX-M-Transmitter <br /> The Transmitter is designed to be connected to any product not classified as explosion proof that provides a dry contact output. Remove the locknut <br /> from the threaded nipple of the Transmitter,make sure the O ring is properly installed on the nipple and insert the nipple through the'h"conduit opening <br /> of the device.Install the locking nut on the inside of the device and tighten firmly in place. <br /> Connect the two wire leads of the Transmitter and the supplied 5.1k ohm End of Line Resistor across the normally open contacts of the device to be <br /> monitored.Polarity is not a concern. <br /> WRX-R-Receiver <br /> The Receiver provides a dry contact output allowing it to be monitored by any zone or monitor module of any fire panel as just a dry contact input. <br /> The Receiver follows the status of the transmitter so it does not have to be manually reset after activation.When the device connected to the transmitter <br /> restores to normal,the transmitter will send a restoral signal to the receiver causing it to restore to normal. <br /> The Receiver provides three terminals for connection to the FACP,see fig 2.Connect the EOLR from the FACP across the COM and EOLR terminals. <br /> Connect the zone from the FACP across the COM and NO terminals.The EOLR and NO terminals are connected internally by a failsafe relay contact <br /> that is normally energized closed. In the event of a trouble signal from the transmitter or repeater, loss of communication or loss of power to the <br /> Receiver,that relay will drop out and initiate a trouble at the FACP.An alarm or supervisory signal from the transmitter will result in a relay closing <br /> across the COM and NO terminals initiating an alarm or supervisory condition on the FACP depending how the panel is programmed. <br /> 1 <br /> • The receiver needs to be connected to a latching trouble zone and re-sound every 4 hours(if silenced).The receiver cannot be monitored by <br /> a zone that uses alarm verification. <br /> • The receiver shall be mounted adjacent to the fire panel. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 5401587-REV B 6/21 PAGE 4 OF 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.