Laserfiche WebLink
• <br /> • <br /> • December 2008 Section 1 General Information Page 1 - 1 <br /> • Amerex Restaurant Fire Suppression System (EX4658) <br /> • GENERAL INFORMATION <br /> • The Amerex KP / ZD Series Restaurant Wet Chemical Fire Suppression System is designed and has been <br /> • tested to provide fire protection for commercial cooking operations covering the hood, ducts, plenum and <br /> appliances. Amerex Restaurant Fire Suppression Systems are a pre-engineered type as defined in NFPA <br /> • 17A — Standard for Wet Chemical Extinguishing Systems. It is manufactured by the Amerex Corporation, <br /> • Trussville, Alabama. <br /> • It is essential that all installations of the Amerex KP I ZD Series Systems be performed in compliance with this <br /> • manual. Those individuals responsible for the design, installation, operation and maintenance of the <br /> Amerex Restaurant Fire Suppression System must be trained by Amerex and hold a current Amerex <br /> • Certificate. All piping limitations, nozzle coverages, detector placements, etc. have been proven and <br /> • established through exhaustive testing by Underwriters Laboratories, Inc. Use of components other than <br /> those referenced in this manual, or installations exceeding limitations stated in this manual will void all of the <br /> • Amerex KP I ZD Series System listings. <br /> • LISTINGS: <br /> • The Amerex KP/ZD Series Fire Suppression Systems are a listed pre-engineered fire extinguishing systems. <br /> 411 The KP &ZD systems are listed with Underwriters Laboratories, Inc. —USA per UL 300 fire test specification; <br /> Underwriters Laboratories of Canada, Inc. per ULC/ORD 1254.6 — 1995 and Loss Prevention Certification <br /> • Board — UK per LPS 1223 rev. B. Testing required for listings under these standards involve live fire tests <br /> under specific conditions involving commercial kitchen hoods, ducts and appliances. Each test fire is allowed <br /> • to reach its maximum intensity before agent is discharged. Each test was repeated using both maximum and <br /> • minimum piping, variations in agent storage cylinder pressure to simulate maximum and minimum <br /> temperature ratings. Duct fire tests were extinguished with fans off and fans on; dampers open and closed. <br /> • Splash tests for various appliances were conducted to assure that discharge of the agent would not cause <br /> r♦ excessive splashing of hot grease to provide greater employee safety during commercial cooking operations. <br /> • UL Standard 300 introduces a series of tests by specifically addressing the use of high efficiency fryers, <br /> • ranges,woks and the unique fire extinguishing challenges that these appliances present. <br /> • DESIGN: <br /> • The Amerex KP Series Pre-Engineered Fire Suppression Systems consist of mechanical and electrical <br /> components to be installed by an Authorized Factory Trained and Certified Amerex Restaurant Fire <br /> O Suppression Systems distributor. The system is composed of an Agent Cylinder/Discharge Valve charged <br /> • with Amerex Kitchen Wet Chemical Agent and a Mechanical Release Module (MRM or MRM II) or Pneumatic <br /> Release Module-'(PRM). The quantity of detectors, fusible links, nozzles, corner pulleys, pulley tees and <br /> • manual pull stations will vary depending on kitchen design. <br /> • The system operates either automatically if actuated by a detector or manually if actuated by a manual pull <br /> • station. Upon system operation, energy sources for the cooking appliances are required to be shut off <br /> immediately. Electrical shutdown devices or suitable gas valves are referenced in this manual. Other <br /> • equipment such as audible/visual signaling devices can be added where required. <br /> • The Amerex Restaurant Fire Suppression System suppresses fire in commercial cooking equipment by <br /> 411 spraying Amerex Wet Chemical Agent in a pre-determined manner onto cooking appliances and into exhaust <br /> . ducts, filters and plenum areas. The primary means of fire suppression is either by saponification of surface <br /> grease or by cooling the surface of oils and hot metal surfaces with fine droplets of agent, reducing the <br /> 411 temperature of the oil and appliance below the auto-ignition point. <br /> O Upon system discharge, the exhaust fans should be left on to aid in dispersal of the liquid suppressant that <br /> • results in cooling the plenum and duct. Any integral make-up or supply air should be automatically shut off <br /> • `-`' along with all cooking appliances. Some local Authorities Having Jurisdiction require exhaust fans to be shut <br /> down by the fire suppression system. Check local fire codes, AHJ and Department of Health in the specific <br /> area that the system is being installed for'special installation requirements. <br /> • The Amerex Restaurant Fire.Suppression System agent storage cylinders and cartridge shall not be installed <br /> • in environments below 32° F or above 120° F (0°C to 49° C). <br />