Laserfiche WebLink
• <br /> • <br /> • September 2009 Section 2 System Components Page 2=6 <br /> • Amerex Restaurant Fire Suppression System (EX 4658) <br /> • NITROGEN ACTUATION CYLINDER: <br /> • 10 in3 N2 Actuation Cylinder(P/N 12856) '~ <br /> • 15 in3 N2 Actuation Cylinder(P/N 09956) } i <br /> Film <br /> mo. . <br /> • The N2 Actuation Cylinder supplies nitrogen gas pressure to the NITROGEN <br /> Agent Cylinder Discharge Valve through the actuation network for the J`. acr ACTUATIO• N <br /> CYLINDERi <br /> purpose of opening the Agent Cylinder. =—; ,,, <br /> • The 10 in3 N2 Actuation Cylinder, P/N 12856, is charged to 1800 psig <br /> • (12410 KPa) at 70°F (21°C) and contains enough nitrogen to actuate Part No. 12856 <br /> • up to ten total of Models 275/375/475 Agent Cylinders Assemblies Diameter 1.998 in 5.07 cm <br /> in any combination OR a total of six Model 600 Agent Cylinders <br /> •, Assemblies OR a total of six Agent Cylinders when the mix contains Length 6 3/8 in 16.19 cm <br /> at least one Model 600 Agent Cylinder Assemblies. <br /> Pressure @ 1800 PSI 12411 kPa <br /> • The 15 in3 N2 Actuation Cylinder, P/N 09956, is charged to 1800 psig 70°F <br /> (12410 KPa) at 70°F (21°C) and contains enough nitrogen to actuate Part No. 09956 <br /> • up to ten total of Models 275 / 375 / 475 & 600 Agent Cylinders <br /> • Assemblies in any combination. Diameter 1.998 in 5.07 cm <br /> • A maximum distance of 100 feet(21.3 meters) to the last control head Length 9.44 in 24 cm <br /> is possible when using the specified copper tubing. Pressure is <br /> • retained in the N2 Actuation Cylinder by a gold plated rupture disc. Pressure @ 1800 PSI 12411 kPa <br /> • Replacement rupture discs are available, P/N 09958. Only genuine 70°F <br /> Amerex rupture discs may be used when recharging Nitrogen Actuation <br /> 111 Cylinders. Proper charge pressure is indicated by a pressure gauge located �� <br /> • on the cylinder's bottom and protected by an impact resistant plastic gauge a <br /> guard. The N2 Actuation Cylinder is shipped fully charged from the Amerex <br /> • factory with a protective shipping cap installed on the outlet threads. The I ` <br /> Aik cap must be removed at installation but must remain in place at all other <br /> Ir times. (Retain the shipping cap to reuse when recharging the N2 Actuation o0 <br /> • Cylinders.) Construction of the N2 Actuation Cylinder is per DOT 3E. The I <br /> cylinder is rechargeable by certified Amerex installers and does not require <br /> periodic hydro-testing. The 10 in3 Nitrogen Actuation Cylinder may be <br /> • used in the MRM, MRM II or PRM. The 15 in3 Nitrogen Actuation Cylinder r o. Li <br /> • may be used only with the ECH. <br /> CABINET (P/N 11978) <br /> • "- <br /> R <br /> Stainless steel cabinets are available for single cylinder systems. The <br /> cabinet will house one model 275 or 375 Agent Cylinder Assembly, the agent <br /> • cylinder mounting bracket and a Mechanical Release Module which are <br /> r• purchased separately. <br /> • <br /> • PiN 11978 U.S. Metric <br /> (A)Width 20'/z' 52.07 cm -c— <br /> • (B) Depth 10$/" 27.3 cm . <br /> • (C) Height 26 1/4" 66.68 cm <br /> it 275/375/475 CYLINDER ENCLOSURE (P/N 16814) <br /> • <br /> Stainless steel enclosure is available for a single model 275/375/475 Agent Cylinder • <br /> • Assembly. The enclosure will house a 275/375/475 Agent Cylinder Assembly and <br /> • does not require the use of a cylinder mounting bracket nor a distributor. The 1 1. \\ <br /> enclosure includes a swivel adapter for connection of the cylinder to the discharge B A <br /> • piping. �'/ ' <br /> • P/N 16814 U.S. Metric <br /> (A)Width 14" 35.6 cm <br /> • (B) Depth 11" 27.9 cm <br /> (C) Height 26 1/4" 66.68 cm <br />