My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-15 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-15
>
3003 W CASINO RD BLDG 40-15 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 11:05:48 AM
Creation date
2/14/2024 11:13:44 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-15
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN SYMBOLS <br /> GROUNDING POWER (CONT) LIGHTING SINGLE LINE SCHEMATIC ABBREVIATIONS GENERAL NOTES <br /> GROUND CABLE CONNECTION ® TELEPHONE/POWER POLE $ $3 $♦ TOGGLE SWITCHES — LINE VOLTAGE, BUS DUCT PRESSURE SWITCH — N.O. AF AMPS—FRAME 1. CONDUIT: 1/2" MINIMUM — TYPE AND SIZE IN <br /> T SINGLE POLE/ 3—WAY/ 4—WAY. NUMBER ��800AF WITH BREAKER �� CLOSES ON RISING PRESSURE AFF ABOVE FINISHED FLOOR ACCORDANCE WITH PLAN DRAWINGS AND THE <br /> TIME CLOCK OF SWITCHES UNDER COMMON PLATE 800 AT AHC ABOVE HUNG CEILING SPECIFICATIONS. <br /> GROUND ROD CONNECTION AS INDICATED AL ALUMINUM <br /> © BUSDUCT PLUG—IN CIRCUIT BREAKER FLOAT OR LEVEL SWITCH — N.C. ATS AUTOMATIC TRANSFER SWITCH 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, <br /> GROUND CABLE PIGTAIL $� 2$L, 3$w LOW—VOLTAGE LIGHTING CONTROL OPENS ON RISING LEVEL AT AMPS—TRIP INSULATION TYPE THHN/THWN, UNLESS OTHERWISE <br /> q SWITCHES. NUMBER OF SWITCHES UNDER 480V AWG AMERICAN WIRE GAUGE NOTED. <br /> —G— GROUND CABLE (UNDERGROUND) POWER RECEPTACLES COMMON PLATE AS INDICATED 1D10-1 PANELBOARD FLOAT OR LEVEL SWITCH — N.O. CB CIRCUIT BREAKER 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS <br /> C,b,C LOWER CASE LETTER INDICATES SWITCHING 600 A (RATINGS AS CLOSES ON RISING LEVEL CFCI CONTRACTOR FURNISHED WHICH DO NOT HAVE APPROPRIATELY COLORED <br /> —G— INSULATED GROUND BUS BAR � DUPLEX 120V RECEPTACLE, HUBBELL CAT. GROUP M.L.O. NOTED) CONTRACTOR INSTALLED INSULATION WITH COLOR TAPE WHEREVER <br /> N0. 5262. PROVIDE LOW—VOLTAGE SWITCH CONTROL 3 PH, 3 W CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED <br /> WIRING AS 3/C #18 AWG IN 1/2" MIN. C FLOW SWITCH — N.C. C.O. CO CONDUIT ONLY GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION <br /> POWER 14 FOURPLEX 120V RECEPTACLE, 2 HUBBELL FROM EACH LOW VOLTAGE SWITCH OPENS ON INCREASE IN FLOW CRU COMPUTER ROOM UNIT #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: <br /> CAT. NO. 5262. TO THE LIGHTING CONTROL PANEL DED DEDICATED <br /> PANELBOARD, 208Y/12OV, 3 PHASE UNLESS OTHERWISE NOTED. 480Y/277V DP DISTRIBUTION PANEL BOARD 208Y 120V 480Y 277V <br /> (111 INDICATES SHUNT—TRIP) 1010-101 PANELBOARD FLOW SWITCH — N.O. EF EXHAUST FAN A 4 (LEFT BUS IN PNL) BLACK BROWN <br /> ffi DUPLEX 120V RECEPTACLE ON DROP CORD 2$. MOTION SENSOR SWITCH CONTROL 225A (RATINGS AS T CLOSES ON INCREASE IN FLOW EMCS ENERGY MANAGEMENT CONTROL SYSTEM B 4 CENTER BUS IN PNL) RED ORANGE <br /> ® PANELBOARD, 480Y/277V, 3 PHASE DED IN ACCORDANCE WITH BOEING STANDARD. MAIN BKR NOTED) EMT ELECTRICAL METALLIC TUBING C 4 RIGHT BUS IN PNL) BLUE YELLOW <br /> O PANELBOARD, 400 HZ, 200Y/115V DEDICATED CIRCUIT. $m LUTRON NTHF-40 HI—LUME FLUORESCENT 30, 4W TEMPERATURE SWITCH — N.C. EPO EMERGENCY POWER OFF NEUTRAL WHITE GRAY <br /> DIMMING CONTROL AND BALLAST STSTEM. ES EPO SWITCH EQUIPMENT GROUND GREEN GREEN <br /> C PANELBOARD, 28 VDCFOURPLEX 120V RECEPTACLE ON DROP OPENS ON RISING TEMP EWC ELECTRIC WATER COOLER ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> GREEN WITH YELLOW TRACER <br /> DED CORD IN ACCORDANCE WITH BOEING $pY INCANDESCENT DIMMER LUTRON FACP FIRE ALARM CONTROL PANEL * <br /> 208V OR 208Y/120V FAR FIRE ALARM RELAY <br /> ® DC PANEL POWER SUPPLY, SIZE AS NOTED STANDARD. DEDICATED CIRCUIT. NTLV 600 SERIES iD10-2 PANELBOARD TEMPERATURE SWITCH — N.O. FATU FAN TERMINAL UNIT 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX <br /> ex EQUIPMENT IDENTIFICATION $or INCANDESCENT DIMMMER, HIGH WATTAGE 225 A (RATINGS AS CLOSES ON RISING TEMP FDP FIRE DETECTION PANEL AND SWITCH WITH CIRCUIT IDENTIFICATION AS <br /> "X" DENOTES EQUIPMENT NUMBER COMMUNICATIONS 1000 M. BKR. NOTED) FVNR FULL VOLTAGE, NON—REVERSING SCHEDULED ON SHEETS E1 B & E1 C, USING TYPED <br /> 'Y DENOTES HP, KVA OR KW RATING 1500 AS NOTED. LNT-1 MODEL NUMBERS: 3 PH, 4 W ��� LABEL. <br /> T TELEPHONE OUTLET NT-1000 LIMIT SWITCH — N.C. GFI GROUND FAULT INTERRUPTER <br /> ® CIRCUIT BREAKER ENCLOSURE 2 NT-1500 COMBINATION STARTER —� GND G GROUND 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON <br /> i DUPLEX TELEPHONE OUTLET RESPECTIVELY LIMIT SWITCH — N.O. HE HORSEPOWER COMPLETION OF JOB. <br /> 3A CONTROLLER OR MCC TO HIGH OUTPUT 6. PANELS ARE TO BE IDENTIFIED BY LAMINATED <br /> DIAGRAM SYMBOLS <br /> ©' CKT. BKR. ENCLOSURE WITH SHUNT—TRIP 1W WALL MOUNTED TELEPHONE OUTLET 7 CUBICLE NUMBER IMC INTERMEDIATE METAL CONDUIT RELAYS & COILS LCP LIGHTING CONTROL PANEL PHENOLIC NAMEPLATES. <br /> ❑' DISCONNECT SWITCH (FUSED OR UNFUSED) — *=TYPE LED LIGHT EMITTING DIODE <br /> 30/20 SWITCH RATING/FUSE RATING © FLUSH MOUNTED SIGNAL BELL SINGLE LINE I M=MOTOR STARTER LV LOW VOLTAGE <br /> EP MOTOR STARTER (COMBINATION)(COMBINATION l OR CR=CONTROL RELAY M. BKR. MAIN BREAKER <br /> / <br /> b MCC MOTOR CONTROL CENTER <br /> TR I® DATA OUTLET ELECTRICAL POWER CONTACTOR MCM MILLION CIRCULAR MILS <br /> ® MANUAL MOTOR STARTER FILTER TR=TIME DELAY OR TIMING <br /> MLO MAIN LUGS ONLY <br /> QV VOLUME CONTROL 2 RELAY NACB NON—AUTOMATIC CIRCUIT BREAKER <br /> T❑ TRANSFORMER (SIZE AS SHOWN, IN KVA) p <br /> STARTER SIZEN.O. CONTACT NEC NATIONAL ELECTRICAL CODE <br /> O JUNCTION BOX Q SPEAKER, CEILING MOUNTED N/A NOT APPLICABLE <br /> FUSED SWITCH NC NORMALLY CLOSED <br /> ® EQUIPMENT CONNECTION El< LOWBAY SPEAKER, N.C. CONTACT NO NORMALLY OPEN <br /> (LOCATION DIAGRAMMATIC) HORN TYPE POWER FACTOR OFCI OWNER FURNISHED, <br /> CORRECTION CAPACITOR N.O. — ON DELAY CONTACT CONTRACTOR INSTALLED <br /> PUSHBUTTON STATION 0<1 MID HEIGHT SPEAKER DISCONNECT SWITCH PPA PAGING H PHASE SYSTEM <br /> OO 460 VOLT MOTOR (SIZE AS NOTED) M HORN TYPE HP MOTOR HORSEPOWER N.C. — ON DELAY CONTACT PNL PANEL <br /> PSS PROGRAMMABLE SYSTEM SWITCH <br /> 4 208 VOLT OR 240 V MOTOR Ct4 CLUSTER HORNS GENERATOR PVC POLY-VINYL CHLORIDE (CONDUIT) <br /> (SIZE AS NOTED) �� N.O. - OFF DELAY CONTACT RF RETURN FAN <br /> SCHEMATIC RVNR REDUCED VOLTAGE, NON-REVERSING <br /> 4 115 VOLT MOTOR (SIZE AS NOTED) U G HTI N GN.C. - OFF DELAY CONTACT SRP SMOKE REMOVAL PANEL <br /> D POWER FACTOR CORRECTION CAPACITOR TRANSFER SWITCH DISCONNECT SWITCH SWBD SWITCHBOARD <br /> GR SWTCHGEAR <br /> HIGH INTENSITY DISCHARGE (HID) SF SUPPLY <br /> FIXTURE FUSE A ETRE ALARM SYSTEM ST SHUNT TRIP CIRCUIT BREAKER <br /> CONDUIT NOT BURIED TBD TO BE DETERMINED <br /> (INCLUDING ABOVE SUSPENDED °� FLOODLIGHT - WALL MTD. / POLE MTD. Ep <br /> CEILING & UNDER RAISED FLOOR) DISCONNECT SWITCH CIRCUIT BREAKER T.D. TIME DELAY <br /> ELEVATOR ALARM BELL <br /> THHN WIRE INSULATION TYPE REFER TO N.E.C. <br /> LIGHTING FIXTURE - 2' x 4' LAYIN FIRE ALARM HORN/STROBE, THAN WIRE INSULATION TYPE REFER TO N.E.C. <br /> --------- BURIED CONDUIT WIRING ® FLUORESCENT WITH 3 TUBES INTERLOCK l``"J TRANSFORMER WALL OR CEILING TLC TOTAL LIGHTING CONTROL (BY G.E.) <br /> (UNDERGROUND & IN FLOOR SLAB) _ M=MECHANICAL �� Os SMOKE DETECTOR T/S TWISTED AND SHIELDED PAIR <br /> FLUOR SCE <br /> ® FIXTURE <br /> WITH 42TUB S AYIN E=ELECTRICAL UH UNIT HEATER <br /> FLEXIBLE METAL CONDUIT INE GROUND CONNECTION DASHED TRANSFORMER lJ ( LQ DUCT SMOKE DETECTOR VHO VERY HIGH OUTPUT <br /> LIGHTING FIXTURE - 2' x 2' LAYIN 0 uj _ WP WEATHER PROTECTED <br /> PHASE HASH CONDUCTOR <br /> DESIGNATIONS ® FLUORESCENT WITH 2 TUBES SHI LADES ELECTROSTATIC \ / Q HEAT DETECTOR <br /> PILOT LIGHT ® *NOTE: SEE SHEET E506 FOR ADDITIONAL FIRE <br /> NEUTRAL CONDUCTOR * REMOTE RELAY <br /> GROUND CONDUCTOR ® LIGHT FIXTURE - 1' x 4' SURFACE OR � SURGE ARRESTER INDICATES COLOR ALARM ABBREVIATIONS. <br /> ISOLATED GREEN GROUND CONDUCTOR PENDANT FLUORESCENT WITH 2 TUBES ❑F MANUAL STATION <br /> CIRCUIT BREAKER W/ � PUSHBUTTON <br /> CIRCUIT SOURCE �/ `� LIGHTING FIXTURES WIRED IN MASTER/ ELECTRICAL OPERATOR MOMENTARY CONTACT WFXx WATERFLOW SWITCH <br /> PANEL/CIRCUIT BREAKER N0.(S) �L(L`�IJ 7L'LQ`J� SLAVE BALLAST CONFIGURATION T NORMALLY OPEN "P" = PRESSURE TYPE, <br /> 1D6-1/1,3,5 (3 2-LAMP BALLASTS FOR 2 3-LAMP F LT = LONG T.D. TRIP UNIT "PD" = PRESSURE TYPE W/DELAY <br /> FIXTURES) / v ST = SHORT T.D. TRIP UNIT <br /> I = INSTANT. TRIP UNIT PUSHBUTTON <br /> D CONDUIT TURNS DOWN LIGHT FIXTURE - FLUORESCENT WITH Y LT GF = GND. FAULT TRIP UNIT MOMENTARY CONTACT PS HI/LO AIR PRESSURE SWITCH <br /> CONDUIT TURNS UP ©OR ALL BALLASTS ON EMERGENCY CIRCUIT NORMALLY CLOSED ❑ <br /> vS TAMPER SWITCH VALVE SWITCH"i <br /> CONDUIT ONLY LIGHT FIXTURE TAP 1/2" FLEXIBLE POTENTIAL TRANSFORMER OFFS SON SELECTOR SWITCH FAC FIRE ALARM COMMUNICATOR <br /> C.O. 7 METAL CONDUIT — 4 #12: TWO PHASE QUANTITY & RATIO y MAINTAINED CONTACT (CELLULAR DIALER) <br /> —E— EMERGENCY CIRCUIT CONDUCTORS, ONE NEUTRAL, ONE GROUND AS SHOWN TWO POSITION#12 FOR SINGLE OR COMMON BALLAST 2 480120 2 FA TC FIRE ALARM TERMINAL CABINET <br /> SWI <br /> —LV— LOW VOLTAGE CIRCUIT <br /> ® INDIRECT LIGHTING FIXTURE CURRENT TRANSFORMER �1 SELECTOR SWITCH FACP FIRE ALARM CONTROL PANEL <br /> —W— WIREMOLD 18000 SERIES DISTRIBUTION 3 800:5 QUANTITY & RATIO �`t'� MAINTAINED CONTACT <br /> SYSTEM REF. E503 AS SHOWN —i—2 THREE POSITION <br /> �--® EXIT SIGN, WALL MOUNTED � <br /> —W— EXISTING WIREMOLD 18000 SERIES AMMETER w/SWITCH <br /> DISTRIBUTION SYSTEM ®i EXIT SIGN, CEILING MOUNTED <br /> SOLENOID VALVE <br /> FIXTURE IDENTIFICATION VS VOLTMETER w/SWITCH 1/ <br /> "X" DENOTES FIXTURE TYPE <br /> Y "Y" DENOTES TOTAL FIXTURE WATTAGE PRESSURE SWITCH - N.C. <br /> WHM WATTHOUR METER � OPENS ON RISING PRESSURE 1 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN AIL SUBTITLE CURRENT REVISION SYMBOL DATE <br /> HIS DESIGN AND/OR CHECKED ELECTRICAL LEGEND 31188306 A 09.18.23 <br /> — EVERETT FIRE PANEL REPLACEMENT— XX W2640474 SAZAN/ZO 04.27.23 SPECIFICATION IS APPROVED SHEET SEQUENCE NO. <br /> Q�BOE//VG <br /> A <br /> N IN TITLE EVERETT FIRE PANEL REPLACEMENT CO <br /> A SHOP DRAWINGS 31188306 AGOW/JS 09.18.23 APPROVED By DEPT. DATE C <br /> CHECKED <br /> BUILDING 40-015 <br /> APPROVED <br /> APPROVED ELECTRICAL MASTER EVERETT, WA. DWG NO, 40-001—EO <br />
The URL can be used to link to this page
Your browser does not support the video tag.