LEGEND <br /> JO JUNCTION BOX 4S UNLESS NOTED OTHERWISE <br /> SO IONIZATION SMOKE DETECTOR <br /> O HEAT DETECTOR FIXED 135' <br /> ❑F MANUAL STATION, DOUBLE ACTING <br /> ® STROBE ALARM <br /> ®� AUDIBLE/VISUAL ALARM <br /> B FIRE ALARM PANEL <br /> ® TELEPHONE PANEL <br /> D ADT PANEL <br /> FAC FIRE ALARM CELLULAR DIALER <br /> GENERAL NOTES <br /> 4 3 2 1. RACEWAY: 1/2" PGS, UNLESS OTHERWISE NOTED. <br /> 2. CONDUCTORS SHOWN: #10 AWG, STRANDED COPPER, <br /> INSULATION TYPE XHHW-2, UNLESS OTHERWISE NOTED. <br /> 3. COLOR CODE CONDUCTORS: INDENTIFY CONDUCTORS <br /> WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION <br /> WITH COLOR TAPE WHEREVER CONDUCTORS ARE <br /> ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS <br /> PER NEC (USING TAPE). COLOR CODE AS FOLLOWS: <br /> 208Y 120V 480Y 277V <br /> A4 (LEFT BUS IN PNL) BLACK BROWN <br /> B4 (CENTER BUS IN PNL) RED ORANGE <br /> CO (RIGHT BUS IN PNL) BLUE YELLOW <br /> zw 1w NEUTRAL WHITE GRAY <br /> EQUIPMENT GROUND GREENGREEN <br /> ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> *GREEN WITH YELLOW TRACER <br /> 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET <br /> BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. <br /> I I <br /> 5. ALL RECEPTACLES SHALL BE NEMA 5-20R RATED <br /> B 45-275 SMK E AND INSTALLED AT A HEIGHT OF 48" ABOVE FINISHED <br /> 45-275 SMK W FLOOR. <br /> 70NEJ 11, L1:11 ZONE #: 10, _1:10 <br /> 0 - F. - 6. POST RECORD (AS-BUILT) PANEL SCHEDULES UPON <br /> COMPLETION OF PROJECT. <br /> el TO FIRE ALARM PANEL LOCATED 1 <br /> IN BLDG 45-209, 3/4"C - 2#14 < <br /> CONSTRUCTION NOTES <br /> INSTALL NEW SMOKE DETECTORS (QTY. 2) WITH <br /> ADDRESSABLE SMOKE DETECTORS COMPATIBLE WITH THE <br /> 45-209 BUILDING FACE. INSTALL CONDUIT AND WIRE AS <br /> I REQUIRED. <br /> 2E E - <br /> B <br /> NOTE: ALL AREAS (INSIDE AND OUTSIDE OF BUILDING) <br /> SHALL BE CLASSIFIED CLASS I, DIVISION 2 UP TO <br /> 18" ABOVE FINISHED GRADE IN ACCORDANCE WITH <br /> FLOOR PLAN KI THE NEC. <br /> SCALE: 1/4"=1'-O" V <br /> 4' 2' 0 2' 4' <br /> SCALE: 1/4"=1'-0" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY J. SHELDON 10.31.23 KLU FIRE ALARM POWER PLAN 29592174 B 10.31.23 <br /> A FACP REPLACEMENT W9063564 JC MDK 03.17.23 SPECIFICATION NSAAPPROVED OR K. MULLEN 11.01.23 SHEET 1 <br /> B SHOP DRAWINGS 29592174 AGOW JS 10.31.23 �"lF'rw�® A <br /> APPROVED BY DEPT. DATE TITLE 1 E60 <br /> �y/J� K. MULLEN 11.01.23 <br /> CHECKED <br /> BUILDING45-275 APPROVED JOB N0. COMP N0. <br /> 29592174 <br /> APPROVED EVERETT, WA DWG NO. 45-275-1E60 <br />