SYSTEM DESIGNATIONS PANEL NOMENCLATURE ABBREVIATIONS LIGHTING FIXTURE SCHEDULE
<br /> X 3 V34-1 U D12 A D NOTE: SEE SHEET E506 FOR FIRE ALARM ABBREVIATIONS TYPE DESCRIPTION VOLTAGE WATTS MFG/NUMBER LAMP LOCATION NOTES
<br /> HASH MARKS INDICATETHE QUANTITY OF SUFFIX "D" INDICATES A/C AIR CONDITIONING PE PRESSURE ELECTRIC KIRLIN
<br /> CONDUCTORTALL S (#12 WIRE UNO.). IF UNMARKED DISTRIBUTION PANEL AC ALTERNATING CURRENT PB PUSHBUTTON
<br /> NS2#12 IN 1/2°CONDUIT SUFFIX "A , BOR C" A.F.F. ABOVE FINISHED FLOOR PR PAIR A CUSTOM BUILT 2'x 2' RECESSED LUMINARE 277 1000 STERNER BALLAST ASSEMBLY METAL HALIDE HIGH BAY RECESSED
<br /> PHASE CONDUCTORS IDENTIFIES A SPECIFIC A.R.F. ABOVE RAISED FLOOR QTY QUANTITY
<br /> NEUTRAL CONDUCTOR(IF REQUIRED) PANEL WHEN SEVERAL AWG AMERICAN WIRE GAUGE RECP RECEPTACLE
<br /> GROUND GONDUCTOR(IF REQUIRED) PANELS OCCUR IN ONE
<br /> AMP AMPERE REF REFERENCE
<br /> 3V34-1,116 7,9,11 LOCATION. APPROX APPROXIMATE REQ'D REQUIRED 277 400 KIRLIN METAL HALIDE LOW BAY RECESSED
<br /> / PANEL LOCATION ARCH ARCHITECT OR ARCHITECTURAL REV REVISION B CUSTOM BUILT 2'x 2' RECESSED LUMINARE
<br /> 3/4"C,3#8 PANEL HOME-RUN
<br /> PANEL/CIRCUIT AT NEAREST COLUMN AUTO AUTOMATIC RGS RIGID GALVANIZED STEEL STERNER BALLAST ASSEMBLY
<br /> CONDUIT/CONDUCTORS LOCATION OF PANEL WHEN ABOVE AUX AUXILIARY RM ROOM
<br /> FIRST FLOOR: BOT BOTTOM SECT SECTION WIDELITE
<br /> CONDUIT RUN EXPOSED TN-TUNNEL, U=2ND FLOOR, V=3RD FLOOR BLDG BUILDING SHT SHEET C EXISTING FLOOD LIGHTS TO BE REPLACED WITH 277V, MH BALLASTS. 277 1000 METAL HALIDE HIGH BAY FLOOD LIGHTS
<br /> CONDUIT RUN CONCEALED IN WALLS, ABOVE W=4TH FLOOR X=5TH FLOOR CAB CABINET SIM SIMILAR I STERNER BALLAST ASSEMBLY
<br /> CEILING, IN FLOOR SLAB OR UNDERGROUND T=TRUSS LEVEL CAT CATALOG SPDT SINGLE POLE DOUBLE THROW CLASS 1 DIVISION 1 EXPLOSION PROOF LUMINAIRE FOR HAZARDOUS AREA. 277 70 KILLARK HPS SCALE ROOMS CEILING MOUNTED
<br /> -E- EMERGENCY CIRCUIT SOURCE OF POWER - VAULT NO. CB CIRCUIT BREAKER SPST SINGLE POLE SINGLE THROW
<br /> CLG CEILING SPEC SPECIFICATION 25070
<br /> VOLTAGE ® 4 PANEL - 480V, 30, 3 WIRE CTR CENTER ST SHUNT TRIP
<br /> -FA- FIRE ALARM CIRCUIT 3 PANEL - 480Y/277V, 30, 4 WIREC 4 FT. INDUSTRIAL FLUORESCENT FIXTURE WITH 10% UPLIGHT, 277 (2) 32 DAY-BRITE (2) T8 TRUSS AREA CEILING MOUNTED
<br /> E
<br /> v 2 PANEL - 208Y/12OV, 30, 4 WIRE CHWR CHILLED WATER RETURN SUSP SUSPEND PORCELAIN REFLECTOR, ELECTRONIC BALLAST AND WIRE GUARD. iF232-PR-1 2EB-277-FL-173
<br /> PA PAGING CONDUIT WITH WIRE AS NOTED CHWS CHILLED WATER SUPPLY SW SWITCH
<br /> INDICATES EMERGENCY PANEL CKT CIRCUIT SYS SYSTEM
<br /> -c- COPPER GROUND WIRE, SIZE AS NOTED "I" INDICATES ISOLATED POWER AND GROUND PANEL COAX COAXIAL TEL TELEPHONE F 4 FT. WALL MOUNTED FLUORESCENT FIXTURE 277 (2) 32 DAY-BRITE (2) T8 CRANE SICK BAY WALL MOUNTED
<br /> -Lv- LOW VOLTAGE CONDUIT/WIRE COL COLUMN T'STAT THERMOSTAT ELECTRONIC BALLAST. WB232 CP-1/2EB-277
<br /> RECEPTACLES C CONDUIT XFMR TRANSFORMER
<br /> CONDUIT TURNED UP C.O. CONDUIT ONLY TYR TYPICAL
<br /> CUSTOM BUILT 2'x 2' DIRECTIONAL RECESSED LUMINAIRE 277 1000 KIRLIN METAL HALIDE HIGH BAY RECESSED
<br /> SINGLE, WITH 30A, 480V, 3?, 4 POLE, WITH CONT CONTINUE UH UNIT HEATER
<br /> CONDUIT TURNED DOWN X30 BACK BOX, GROUND THRU EXTRA POLE AND SHELL. CU COPPER UG UNDERGROUND STERNER BALLAST ASSEMBLY
<br /> �fZJ FLEXIBLE CONDUIT, 1/2" UNO CT CURRENT TRANSFORMER U.O.N. UNLESS OTHERWISE NOTED
<br /> DUPLEX,20A,120V,1?,2P,3W, PARALLEL BLADE QUARTZ FLOOD LIGHT. ONE PIECE DIE-CAST ALUMINUM HOUSING WITH DAY-BRITE
<br /> DC DIRECT CURRENT VAV VARIABLE AIR VOLUME 20 500 QUARTZ HIGH BAY EMERGENCY
<br /> 3E CONDUIT TO BE REMOVED GROUNDED DED DEDICATED CIRCUIT VERT VERTICAL H SIDE HINGES,TEMEPERED GLASS. QF-500-LP-120 FLOOD LIGHTS
<br /> FOURPLEX-2 DUPLEX, 20A,14,2P,3W DEG DEGREE B WP WEATHERPROOF 2'x4' FLUORESCENT GRID TROFFER. LIGHT FIXTURES TO HAVE 12 PATTERN 277 (2) 32 LITHONIA (2) T8 HALLWAY RECESSED
<br /> EQUIPMENT TO BE REMOVED (EG. PANELBOARD) PARALLEL BLADE GROUNDED. DET DETAIL WH WATER HEATER J ACRYLIC DIFFUSERS, 0.125" THICK. ENERGY SAVING ELECTRONIC BALLAST 2GT-232-A12125-277-GEB-GMF 3500°K
<br /> WP WEATHERPROOF DUPLEX RECEPTACLE, 15A, 120V, 14, DIAM DIAMETER W WATT
<br /> TH
<br /> DISTRIBUTION 2P, 3W PARALLEL BLADE, GROUNDED FA FIRE ALARM W/0 WITH OUT X DIE CAST ALUMINUM EXIT FIXTURES, DUAL VOLTAGE INPUT 120/277 VAC, 60'. 277 8.7W SURELITES LED HALLWAY SURFACE MOUNT
<br /> GFI GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE FACP FIRE ALARM CONTROL PANEL T FOOT RED LETTERS ON WHITE HOUSING FINISH. LED LAMPS. CAX - 7 1 70 00 - R W
<br /> ® PANELBOARD, 48OV, 34, 3W, PANELBOARD 20A, 120V, 14, 2P, 3W PARALLEL BLADE, GROUNDED FATC FIRE ALARM TERMINAL CABINET FURN FURNISH / KIM WM2-CUSTOM SLIPFITTER MOUNT, METAL HALIDE FIXTURE, TO COME KIM #AFL31/1000SMH277/LG- METAL MOUNT TO CENTER
<br /> PANELBOARD, 480Y/277V, 30, 4W, PANELBOARD, GEN GENERATOR K COMPLETE WITH 3C, 12 AWG 10 FT. SIEMENS 5DH3-511 CORD, SAFETY CHAIN 277 1000 LESS BALLAST, GREY HALIDE LOW BAY OF I-BEAM
<br /> INFO INFORMATION GRN GREEN
<br /> v PANELBOARD, 208Y/12OV, 34, 4W, PANELBOARD4FT. FLOURESCENT OPEN "STRIP" PRUDENTIAL#
<br /> AUXILIARY SYSTEMS JB JUNCTION BOX GND GROUND P-T5-WG-04'-BWE-277 28W JANITOR SURFACE
<br /> KW KILOWATT HTR HEATER L FIXTURE WITH BAKED ENAMEL FINISH 277 28 T5
<br /> Mcc MOTOR CONTROL CENTER 010 P.A. SYSTEM
<br /> gTOR, WALL MOUNTED AND WITH WIRE GUARD CLOSET
<br /> G) KWH KILOWATT HOUR HGT HEIGHT
<br /> D 400Hz PANEL KV KILOVOLT HID HIGH INTENSITY DISCHARGE 4" VERTICAL DOWNLIGHT. LOW IRIDESCENT CLEAR ALUMINUM REFLECTOR (1) PORTFOLIO # 18W
<br /> P.A. SYSTEM SINGLE HORN LGTH LENGTH HZ HERTZ v TEMPERED GLASS FRESNEL LENS. SELF FLANGED TRIM RING. ELECTRONIC 277 18 C4018E-4081LI4G TRT RESTROOMS PENDANT
<br /> o SPECIAL PANEL AS NOTED ) LT LIGHT HPS HIGH PRESSURE SODIUM VI PROGRAM START BALLAST. UL LISTED WET LOCATION.
<br /> } P.A. SYSTEM TWO(2) HORN CLUSTER LG LONG HV HIGH VOLTAGE 4' LINEAR LOW PROFILE WALL MOUNT FLUORESCENT (1) LAMP FIXTURE, PRUDENTIAL
<br /> EQUIPMENT/DEVICES � MAG MAGNETIC HORIZ HORIZONTAL �I STEEL CONSTRUCTION, ALUMINUM END PLATES, WHITE EXTRUDED ACRYLIC 277 (1) # 28W RESTROOMS WALL
<br /> P.A. SYSTEM THREE(3) HORN CLUSTER MAI NT MAINTENANCE HE HORSEPOWER N 28 S1-1T5-04-YGW-277- T5
<br /> $ SINGLE POLE TOGGLE SWITCH MFG MANUFACTURER IG ISOLATED GROUND WRAP AROUND LENS. WHITE FINISH. UL LISTED DAMP LOCATION. SUR-10THD
<br /> P.A. SYSTEM FOUR(4) HORN CLUSTER MAX MAXIMUM EA EACH ^I SAME AS TYPE N EXCEPT PENDANT HUNG 1 PRUDENTIAL # 28W
<br /> $3 THREE-WAY TOGGLE SWITCH MECH MECHANICAL EL ELEVATION N-1 277 ) S1-iT5-04-YGW-277- RESTROOMS PENDANT
<br /> SPEAKER, RECESSED MOUNTED IN CEILING MEZZ MEZZANINE ELECT ELECTRIC 8 CA48-10THD T5
<br /> O
<br /> PUSHBUTTON STATION MIN MINIMUM EMT ELECTRICAL METALLIC TUBINGSAME AS TYPE N-1 EXCEPT 8' IN LENGTH PRUDENTIAL
<br /> Q MAGNETIC DOOR RELEASE MISC MISCELLANEOUS EVER EMERGENCY N-2 277 (2) S1-iT5-08-YGW-277- 28W RESTROOMS PENDANT
<br /> ® MANUAL MOTOR STARTER MTD MOUNTED ENGR ENGINEER 28 CA48-10THD T5
<br /> ® MAGNETIC MOTOR STARTER ® TELEPHONE CABINET MTG MOUNTING EQUIP EQUIPMENT HIGH EFFICIENCY BASKET TYPE FIXTURE. 20 GA. STEEL CONSTRUCTION FOCAL POINT #
<br /> NEC NATIONAL ELECTRIC CODE ETC ETCETERA MATTE WHITE ANITMICROBIAL POWDER COAT FINISH. FROSTED ACRYLIC DIFFUSER 277 2) FAR22AC2T5S277GiWHA 14W BREAK ROOM RECESSED
<br /> Ep LIGHTING COMBINATION STARTER, CIRCUIT BREAKER TYPE, NC NORMALLY CLOSED EWC ELECTRIC WATER COOLER WITH MICRO PRISM PATTERN. PROGRAM START BALLAST. UL LISTED. 4 T5
<br /> 30A UNLESS NOTED OTHERWISE FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE, NIC NOT IN CONTRACT EXIST EXISTING
<br /> gi A 12" ADJUSTABLE COVE LIGHT. 120V WIRING WITH INTEGRAL 120 4.5 COLOR KINETICS # LED RESTROOMS
<br /> DWG. FEOb. QUANTITY AND RATING OF LAMPS NO NORMALLY OPEN EXTR EXTERIOR
<br /> ENCLOSED CIRCUIT BREAKER SIZE AS NOTED -aa POWER SUPPLY. MOUNTING TRACK FOR INSTALLATION. 4200K 12"-#523-000004-03 WALL
<br /> ON DRAWING (A=TYPE, 2=QUANTITY, 34=LAMP RATING) NTS NOT TO SCALE EXP EXPLOSION PROOF r
<br /> No. OR # NUMBER FDR FEEDER
<br /> Cy DISCONNECT SWITCH, FUSED, 30=SWITCH RATING, HIGH INTENSITY DISCHARGE FIXTURE, TYPE AS NOTED OC ON CENTER FIXT FIXTURE SAME AS YRE P EXCEPT 6" LONG 120 COLOR KINETICS # LED RESTROOMS
<br /> n 2.2 6"-#523-000005-03 WALL
<br /> W/20 20-FUSE RATING � INCANDESCENT OR COMPACT FLUORESCENT FIXTURE OD OUTSIDE DIAMETER FLEX FLEXIBLE r 1 #
<br /> ON EMERGENCY SYSTEM, TYPE AS NOTED PN L PANEL FLR FLOOR
<br /> DISCONNECT SWITCH, NON-FUSED, 30A % PERCENT 4' SMALL PROFILE UNDERCABINET LIGHT. EXTRUDED ALUMINUM CONSTRUCTION. ALKCO
<br /> UNLESS NOTED OTHERWISE Fe f EXIT LIGHTING SIGN, WALL MOUNTED. PERP PERPENDICULAR Q WHITE POWDER COAT ANTIMICROBIAL FINISH. UL LISTED. 277 28 W L2F4-277-SWH TS# 28W BREAK ROOM SURFACE
<br /> ® MOTOR CONTROLLEREXIT LIGHTING SIGN, SUSPENDED OR CEILING 0 OR PH PHASE
<br /> ® PVC POLYVINYL CHLORIDE 21" SOLATUBE DAYLIGHT SYSTEM. UV AND IMPACT RESISTANT ACRYLIC OUTER
<br /> LI TRANSFORMER, SIZE AND TYPE AS NOTED MOUNTED. DIRECTION OF EGRESS AS NOTED PWR POWER R AND INNER DOME WITH 92% LIGHT TRANSMISSION. SPECULAR ALUMINUM TUBE. NA NA S75ATUBE# NA LOCKER ROOM SURFACE
<br /> S0DS-DA-DAI-F11-E02-L1-I
<br /> 4 ® 1'x4' (1) LAMP FIXTURE PF POWER FACTOR SELF MOUNTED FLASHING. OPTIVIEW DIFFUSER. UL LISTED.
<br /> MOTOR, 120V,1?, SIZE AS NOTED ® LIGHT ON EMERGENCY CIRCUIT DEPT DOUBLE POLE DOUBLE THROW
<br /> 4 MOTOR, 208V, 3?, SIZE AS NOTED d LED COVE LIGHT. DDNST DDOOWBLE POLE SINGLE THROW
<br /> MOTOR, 460V, 3?, SIZE AS NOTED $ SWITCH DWG DRAWING
<br /> © JUNCTION BOX, FIELD SIZED OR AS NOTED $� OCCUPANCY SENSOR SWITCH
<br /> OS OCCUPANCY SENSOR
<br /> GROUNDING PIGTAIL PC PHOTOCELL
<br /> O PULLBOX, FIELD SIZED OR AS NOTED
<br /> FIXTURE CALLOUT
<br /> ME JUNCTION BOX, SPECIAL. FIELD SIZED OR AS NOTEDY 'X' DENOTES TYPE
<br /> © GENERATOR, ALTERNATING CURRENT
<br /> Y DENOTES FIXTURE WATTAGE B
<br /> (VOLTAGE, KW, FREQUENCY AS NOTED)
<br /> O GROUND ROD, SIZE AS SPECIFIED OR NOTED F- PRESSURE
<br /> E ALARM SYSTEM FIRE ALARM SYSTEM (CONT.)
<br /> N TELEPHONE OUTLET, WALL MOUNTED 12" ARF OR AS NOTE MF
<br /> m TELEPHONE OUTLET MOUNTED IN RAISED FLOOR VATOR ALARM BELL ❑VS LX:xx TAMPER SWITCH (VALVE SWITCH)
<br /> SUBSCRIPT LXXX = DEVICE ADDRESS
<br /> 13 DATA OUTLET MOUNTED IN RAISED FLOOR ALARM HORN, WALL OR CEILING FAC FIRE ALARM COMMUNICATOR PANEL
<br /> PUSHBUTTON STATION, TYPE AS NOTED ALARM HORN/STROBE, WALL OR CEILING FACP FIRE ALARM CONTROL PANEL
<br /> CONTROL PANEL KE DETECTOR, SUBSCRIPT LX:XX = DEVICE ADDRESS BATT BATTERY CABINET
<br /> ANN ANNUNCIATOR (FIRE ALARM)
<br /> UAL STATION, SUBSCRIPT LXXX = DEVICE ADDRESS= WEATHERPROOF, "EP" = EXPLOSIONPROOF B MISCELLANEOUS PANEL/EQUIPMENT, TYPE AS NOTED
<br /> ERFLOW SWITCH, SUBSCRIPT LX:XX = DEVICE ADDRESS,
<br /> - PRESSURE TYPE, "PD" = PRESSURE TYPE W/DELAY 1)LXXX HEAT DETECTOR, SUBSCRIPT LX:XX = DEVICE ADDRES
<br /> PS Lx:xx HI/LO AIR PRESSURE SWITCH
<br /> SUBSCRIPT LXXX = DEVICE ADDRESS
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEDRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> A FACP REPLACEMENT W9063564 JC MDK 03.17.23 ACCEPTABILITY J. KLU N 10.31.23 INDEX SHEET
<br /> 295921 74 i Q.31.23
<br /> SPTHISECIFICDESIGN ANDIOR CHECKED ATION IS APPROVED K. MULLEN 11.01.23 SHEET
<br /> B SHOP DRAWING 29592174 AGOW JS 10.31.23 BOE/NG® APPROVED BY DEPT DATE TITLE EVERETT FIRE PANEL REPLACEMENT EOA
<br /> � K. MULLEN 11.01.23
<br /> CHECKED
<br /> APPROVED BUILDING 45-233
<br /> JOB No. 28592174 coMP No.
<br /> APPROVED EVERETT, WA. DWG NO. 45-233-EOA
<br />
|