My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-233 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-233
>
3003 W CASINO RD BLDG 45-233 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 9:37:53 AM
Creation date
2/14/2024 11:20:49 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-233
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FACP BATTERY CALCULATIONS <br /> COMPONENTS orv. CUBRENT CURRENT REM POWER CABLE (SUPPLIED <br /> AFC-100(FACP) 1 0.13000A 0.22000A WITH PEM <br /> UD-2000(DACT) 1 0.01600A 0.02300A 6 5 3 4 <br /> SLC DEVICES SUPERVISORY ALARM <br /> CURRENT CURRENT <br /> PAD-PD 4 0.00030A 0.00030A 0.00120A 0.00120A 1 <br /> PAD-HD 2 0.00030A 0.00030A 0.00060A 0.00060A <br /> PAD-DUCT 0 0.00030A 0.00030A O.D000OA O.Oo000A <br /> PAD100-PSSA/PSDA 3 O.00020A 0.00020A 0.00060A 0.00060A <br /> PAD100-RM 0 0.00024A 0.00024A O.000OOA O.000OOA <br /> PAD-MIM 00.00020A 0.00040A o.000OOA O.000OOA 3 3/4"C - 2#14THHN,1#14G Z B <br /> PAD100-DIM 0 0.00024A 0.00024A O.000OOA O.o0000A TG-PEM <br /> STANDBY ALARM <br /> CURRENT CURRENT �K <br /> NAC CKT 1(AUX PWR) o.018A 0.11000A 0.018004 0.11007A FACP EVT-FA-45-233 TG-7 ES <br /> NAC CKT 2 O.00A 0.49300A 0.000OOA 0.493004 <br /> 0.004 0.000004 0.000004 0.000004 (BY FIRE ALARM VENDOR) URN 1 4 7 <br /> SLC ALARM LED O.00A 0.03600A 0.000OOA .,3160 OA R <br /> TOTAL 1 0.15640A 0.884404 3 <br /> TOTAL STANDBY CURRENT DRAW- 0.157 AMPS T <br /> X STANDBY TIME 48 HOURS <br /> STANDBY AMP HOUR TOTAL- 7.507 AH DG STC2 STGI TRIP BATT AG <br /> TOTAL ALARM CURRENT DRAW- 0.8844 AMPS 1 2 1 2 3 4 5 6 1 2 3 1 2 G <br /> X ALARM TIME 0.167 HOURS �� �� BB <br /> ALARM AMP HOUR TOTAL= 0.148 AN <br /> STANDBY AH + ALARM AH = 7.655 AH ILK <br /> X DE-RATING FACTOR 1.20(207) RE0 EOL(q5 NEEDED) <br /> TOTAL AH REQUIRED= 9.19 AH <br /> MINIMUM BATTERY SIZE NEEDED: 10 AH <br /> BATTERY SIZE PROVIDED: 12 AH <br /> NOTE: 0.167 EQUALS 10 MINUTES OF ALARM TIME <br /> 3/4"C - (1) PHONE CABLE, <br /> (1) 2 CONDUCTOR FPL OR <br /> APPROVED EQUAL <br /> FACP VOLTAGE DROP CALCULATION CONSTRUCTION NOTES <br /> CIRCUIT SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE VOLTAG <br /> NAME VOLTAGE CURRENT WIRE TYPE 000 F. EEET RESISTANCE VOLTAGE DROP% [j�::, PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> NAC1(AUX) 20.4 VDC 0.110 A #14AWG SOLID 3.07 10 0.0614 20.393 VDC 0.03% THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> NAC2 20.4 VDC 0.493 A #14AWG SOLID 3.07 117 0.7184 20.05 VDC 1.74% SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> N/A 20.4 VDD 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDC 0% EIRE ALARM SYSTEM COMMUNICATIONS DETAIL COMPATIBLE WITH AT&T CELL SERVICE. <br /> N/A 20.4 VDC 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDC 0% SCALE: NONE 7260 E506 <br /> PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> O� �o0`S STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> �O 00 DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. BUILDING FACP. <br /> P6 STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS 3 PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> QS �O �� QS QS OFF OFF p� X00 TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> cn� cn� C;t OPO COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> MONITORED BY TYCO AND APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. MODULE AND WIRE AS SHOWN. MAINTAIN <br /> F F F S S S MIM CELLULAR * MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> 1:07 L1:05 L1:04 1:08 1:06 L1:02 L1:03 L1:01 1:10 ANAL G PHON LINE DIALER SIGNAL SENT TO CENTRAL STEP 3: IF ACCEPTABLE SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR BETWEEN POWER AND COMMUNICATION WIRING. <br /> L RIM A R Y� TG-7FS-A BOEING FIRE DEPARTMENT CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL COORDINATE <br /> WP45-233 FACP *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE, AS SHOWN. WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. 4 PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> NAC2 STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE BACKGROUND, THAT READS: <br /> 30CD 110CD 15CD 15CD 75CD FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED <br /> WITHIN 20FT OF EACH OTHER. "FIRE ALARM CELLULAR DIALER" <br /> ANALOG PHONE LINE STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> OHO (SECONDARY) BUILDING FACP. STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> OS EVT-FA-45-233 STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> SOLE PATH FOR FIRE COMMUNICATIONS. IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> S L1:09 '2VS11/11c" TO BOEING ENGINEER. <br /> SLC 3/4"C - 2#14 *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ 6 ORDINANCES. FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> BUILDING FIRE ALARM SYSTEM RISER "FIRE ALARM CELLULAR ANTENNA" <br /> SCALE: NONE E506 <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> SCALE: NONE E260 E506 PRINTEDS LABEL, HANDWRITTENHANDWR TTEELLUAR ON EINFORMATION PIS ROVIDE <br /> 45-233 BUILDING SYSTEM FACP POINTS ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> INFORMATION TO BOEING ENGINEER. <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. <br /> L1:001 1 SMK @ FACP FACP SMOKE DETECTOR <br /> L1:002 2 SMK OFFICE CENTER OFFICE CENTER SMOKE DETECTOR <br /> BILL OF MATERIALS <br /> L1:003 3 SMK OFFICE WEST OFFICE WEST SMOKE DETECTOR <br /> ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> _1:004 4 HEAT WOMEN RESTROOM WOMENS R.R. HEAT DETECTOR <br /> 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> L1:005 5 HEAT MENS RESTROOM MENS R.R. HEAT DETECTOR <br /> _1:006 6 MAN PULL DR N1 NORTH EXIT MANUAL PULL 2 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:007 7 MAN PULL DR S2 S.E. EXIT MANUAL PULL 3 6 3992732 POTTER PAD100 6" BASE <br /> L1:0o8 8 MAN PULL DR S1 S.W. EXIT MANUAL PULL 4 4 3992770 POTTER PAD200 PHOTO DETECTOR <br /> _1:009 9 45-257 SMK CENTER BLDG. 257 CENTER SMOKE DETECTOR 5 2 3992735 POTTER PAD100 HEAT DETECTOR(1350 FIXED) <br /> L1:010 10 45-233 DACT TRBL IBLDG. 233 CELLULAR DIALER TROUBLE 6 1 3 1 3992720 POTTER PAD100 PULL STATION <br /> 7 1 3992700 POTTER PAD100 MICO INPUT MODULE <br /> 8 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> BUILDING FACP POINTS LIST9 2 BK-P2RL SYSTEM SENSOR HORN/STROBES <br /> 10 2 BK-SCRL SYSTEM SENSOR STROBES <br /> SCALE: NONE E106 11 1 BK-P2RK SYSTEM SENSOR WEATHER PROOF HORN/STROBES <br /> 12 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> 13 1 SSU00689 SPACEAGE FIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> A FACP REPLACEMENT W9063564 JS MDK 03.17.23 ACCEPTABILITY J. CKLU N 10.31.23 FIRE ALARM SYSTEM DETAILS <br /> THIS DESIGN AND/OR CHECKED 29592174 11.Q 1'23 <br /> SPECIFICATION IS APPROVED K. MULLEN 11.01.23 SHEET <br /> B SHOP DRAWINGS 29592174 AGOW JS 10.31.23 BOE//VG® A <br /> APPROVED BY DEPT. DATE TITLE E506 <br /> K. MULLEN 11.01.23 <br /> NECKED <br /> BUILDING 45-233 JOB NO COMP NO. <br /> APPROVED 29592174 <br /> APPROVED EVERETT, WA DWG NO. 45-233-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.