SAUNDERS KITCHEN ADDITION I December 3, 2019 SDA Job# 8855 I 7 <br /> ROOF-TRIAGE WALL SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g.Roof,4TH,3RD.2ND 1.0 tributary width 1.0 tributary area <br /> Lt-Rt Load Direction.e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall.Use Front-Rear Load Direction) Tributary Area(2ND) Tributary Area(2ND) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall Segment Lengths: Aay,Total Length= 12.0 ft tributary width tributary area <br /> 12.0 ft I r I I t total width total area <br /> TributaryArea(NA) Tributary Area(NA) <br /> EV(ROOF)= 18980 lb 13574 lb tributary width tributary area <br /> EV()= 0 lb 0 lb total width total area <br /> EV()= 0 lb O lb <br /> EV()= 0 lb 0 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> i E(Wind)= 18,980 lb E(Smc)= 13,574 lb Length of Shearwall= 12.0 ft Tributary width for dead load= 13.0 ft <br /> ULT.V= 791 PLF ULT.v= 566 PLF Aspect Ratio OK Length of adjoining wall= 2,0 ft <br /> I DRAG(ASD)= 5,694 lb 4,751 lb Use alternate R factor for seismic? No R= 6.5 <br /> } ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 00 Holdown Design? Yes Do= 2.5 <br /> WIND CAPACITY:1.4 x 0.93 x 1020 PLF/(2 x 0.6)=1106 PLF Ductile Anchor Design? No Block Shear Wall <br /> SEISMIC CAPACITY:1 x 0.93 x 1020 PLF i(2 x 0.7)=677 PLF USE A 3X framing per IBC <br /> Floor Above: NO FLOOR ABOVE I Seamic controls.sheanu li design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 3796 lbs = 3796 lbs Wind controls-C1(ASD eq,5): <br /> ASD T.TOTAL w/o DO= (floor above)+(this floor)= 0 lbs + 3069 lbs = 3069 lbs Wind controls-T1(ASD eq.7): <br /> LRFD T.TOTAL w/CO= (ffoorabove)+(this floor)= 0 lbs + 9746 lbs ir= 9746 lbs Seismic DO controls-T3(LRFD eq.71: <br /> Unfactored C.WL=6327 lbs Unfactored T.WL=7314 lbs I SIMPSON DESIGNED HOLDOWN:I MST48 I <br /> Unfactored C,EQ=4525 lbs Unfactored T.EQ=4525 lbs FOUNDATION 1 INTERIOR WALLS: HDU4-SDS2.5 INSTALL THROUGH <br /> Unfactored C.DL= 2200 lbs Unfactored C,LUSL=2600 lbs L W/Sirr'SS ROD I STEM&FT'G <br /> ROOF NORTH WALL SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> ROOF Floor Level,e.g,Roof,3RD,2ND, 1ST., 6.0 i tributary width 162,0 i tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 86.0 total width 3700.0 total area <br /> (For Left Wall.Use Front-Rear Load Direction) Tributary Area(2ND) Tributary;Area(2ND) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) tributary width tributary area <br /> total width total area <br /> ROOF Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Sheerwall Segment Lengths: Adi.Total Length= 11.6 ft tributary width tributary area <br /> 4.0 ft I 2.5 ft 1 6.0 ft I I 1 total width total area <br /> Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 18980 lb 13574 lb tributary width tributary area <br /> EV O= 0 lb 0 lb total width total area <br /> EVO= Olb 01b <br /> EV O= 0 lb 0 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 lbs <br /> E(Wind)= 18,980 lb E(Smc)= 13,574 lb Length of Shearwall= 2_5 ft Tributary width for dead load= 6,0 ft <br /> ULT.v= 115 PLF ULT.v= 51 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> Use alternate R factor for seismic? No R= 6,5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 D0 Holdown Design? No Do= 2,5 <br /> WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No Block Shear Wall <br /> SEISMIC CAPACITY:!x 0:93 x 460 PLF I(2 x 0.7)=305.PLF USE <br /> Floor Above: NO FLOOR ABOVE Witrd coitir ore,Sin;.tiwall design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 550 lbs = 550 lbs Wind controls-C1(ASD eq,5): <br /> ASD T.TOTAL w/o D0= (floor above)+(this floor)= 0 lbs + 329 lbs = 329 lbs Wind controls-T1(ASD eq.7): <br /> I Unfactored C.WL=916 lbs Unfactored T.WL= 1101 lbs NO HOLDOWNS REQUIRED l: OK <br /> i Unfactored C,EQ=411 lbs Unfactored T.EQ=411 lbs FOUNDATION/INTERIOR WALLS: J' <br /> 1 Unfactored C,DL= 553 lbs Unfactored C,LL/SL=488 lbs <br />
The URL can be used to link to this page
Your browser does not support the video tag.