Laserfiche WebLink
SAUNDERS KITCHEN ADDITION I December 3, 2019 SDA Job# 8855 1 9 <br /> 2ND-WEST WALL SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info TrdbutaryArea(ROOF) Tributary Area(ROOF) <br /> 2ND Floor Level,e.g.Roof,4TH,3RD,2ND 23.5 tributarywidth 746.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 62,0 total width 3700,0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(2ND) Tributary Area(2ND) <br /> CDX Sheathing type(T4.3A of SDPWS-2015) 23,5 tributary width 746,0 tributary area <br /> 62.0 total width 3266.0 total area <br /> 2ND/FL Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall Segment Lengths: Adj.Total Length= 26.0 ft tributary width tributary area <br /> 7.0 ft I_ 14.0 ft I 5.0 ft 1 1 ] total width total area <br /> Tributary Area(NA) Tributary Area(NA) <br /> EV(ROOF)= 9669 lb 13574 lb tributary width tributary area <br /> EV(2ND FLOOR)= 14900 lb 6922 lb total width total area <br /> EV O= 0 lb 0 lb <br /> EV()= 0 lb 0 lb Height of Shearwall= 8,5 ft Weight of Shearwall= 10.0lbs <br /> I E(Wind)= 24,569 lb E(Smc)= 20,496 lb <br /> ULT.V= 166 PLF Length of Shearwall=E 5,0 ft Tributary width for dead load= 11.5 ftULT.V= 356 PLF Aspect Ratio OK Length of adjoining wall= 2,0 ft <br /> Use alternate R factor for seismic? No R= 6,5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 C10 Holdown Design? Yes Do= 2.5 <br /> WIND CAPACITY:1.4 x 0.93 x 460 PLF/(2 x 0.6)=499 PLF Ductile Anchor Design? No Aikik Block Shear Wall <br /> SEISMIC CAPACITY:1 x 0.93 x 460 PLF/(2 x 0.1)=305 PLF USE <br /> FloorAbove:I ROOF WEST WALL 6 FAMILY RM. iNind col l(To Is si,:aari'el c/ns/:7n <br /> ASD C.TOTAL,= (floor above)+(this floor)= 489 lbs + 1827 lbs = 2316 lbs Wind controls-CI(ASO eq,5): <br /> ASD T.TOTAL w/o CIO= (floor above)+(this floor)= 16 lbs + 1225 lbs = 1241 lbs Wind controls-71(ASD eq.7): <br /> LRFD T.TOTAL w/DO= (floor above)+(this floor)= 533 lbs + 2815 lbs = 3348 lbs Seismic DO controls-T3 LRFD eq.7'): <br /> I Unfactored C.WL=3859 lbs Unfactored T.WL=4460 Ibs-I SIMPSON DESIGNED HOEDOWN: I HDU8-SDS2.5 <br /> I Unfactored C EQ=2021 lbs Unfactored T.EQ=2021 lbs I FOUNDATION I INTERIOR WALLS: 1 w/7/8"ROD F1554 GR36 <br /> 1 Unfactored C.DL= 2393 lbs Unfactored C,LLISL=2203 lbs ji 17.5'EMBED <br /> 2ND-NORTH BREEZEWAY SEGMENTED SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Area(ROOF) Tributary Area(ROOF) <br /> 2ND Floor Level,e.g.Roof,3RD,2ND,1ST.. 31.0 :tributary width 1003,0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 86.0 total width 3700.0 !OM area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Area(2ND) .Tributary Area(2ND) <br /> 'CDX Sheathing type(T4.3A of SDPWS-2015) 23,0 tflbttta ywidth 486.0 tributary area <br /> 86_0 jtotal width 3266.0 total area <br /> 2ND/FL Resisting Dead Load Tributary Area(NA) Tributary Area(NA) <br /> Shearwall Segment Lengths: Ail,Total Lamp 15.0 ft tributary width tributary area <br /> 15.0 ft I 1 I I I total width total area <br /> TributaryArea(NA) Tributary Area(NA) <br /> EV(ROOF)= 18980 lb 13574 lb tributary width tributary area <br /> EV(2ND FLOOR)= 19040 lb 6922 lb total width total area <br /> EV O= 0 lb 0 lb <br /> EV O= 0 lb 0 lb Height of Shearwall= 8.0 ft Weight of Shearwall= 10,0 lbs <br /> I E(Wind)= 38,020 lb E(Smc)= 20,496 lb Length of Shearwall= 15.0 ft Tributary width for dead load= 6.0 ft <br /> ULT.V= 796 PLF UL7 V= 314 PLF Aspect Ratio OK Length of adjoining wall= 2.0 ft <br /> Use alternate R factor for seismic? No R= 6.5 <br /> ASD SHEAR WALL DESIGN PER:AF&PA SDPWS-2015 DO Holdown Design? Yes Do= 2.5 <br /> WIND CAPACITY:1.4 x 0.93 x 1020 PLF/(2 x 0.6)=1106 PLF Ductile Anchor Design? No Block Shear Wall <br /> SEISMIC"CAPACITY':1 x0;93:x IO2OPLF/(2x0.1)=87TPLF USE 1 3x framing per 1BC <br /> Floor Above: NO FLOOR ABOVE Wind colitrofs si3earwalr'design <br /> ASD C.TOTAL= (floor above)+(this floor)= 0 lbs + 3819 lbs = 3819 lbs Wind controls-C1(ASD eq,5): <br /> ASD T.TOTAL w/o DO= (floor above)+(this floor)= 0 lbs + 2952 lbs = 2952 lbs Wind controls-T1(ASD eq,7): <br /> LRFD T.TOTAL w/DO= (floor above)+(this floor)= 0 lbs + 5252 lbs = 5252 lbs eisrnic DO controls:T3 LRFD eq.7-) <br /> Unfactored C.WL=6365 lbs Unfactored T.WL=6365 lbs I SIMPSON DESIGNED HOLDOWN: 1 I4bU2- OS .5 ( <br /> f Unfactored C EQ=2512 lbs Unfactored T.EQ=2512 lbs I FOUNDATION/INTERIOR WALLS: 1 W/518"SS,ROD [INSTALL THROUGH <br /> 3 Unfactored C.DL= 1444 lbs Unfactored C.LL,SL=684 lbs . STEM&FIG <br />