Drew Martin <br /> From: Drew Martin <br /> Sent: Friday,July 9, 2021 1:11 PM <br /> To: joe luckey'; Paula Sweeney <br /> Subject: City of Everett Permit Services: 617 Legion Drive (B2104-076) - Second Building Intake <br /> Review <br /> Joe, <br /> Please see the following supplemental comments, itemized for consistency with the comments emailed on <br /> 05/10/2021. Please send hardcopies of the revised drawings(2 sets) and any other support documentation (if <br /> applicable)via the standard resubmittal process. The documents should include an itemized response letter addressing <br /> all comments in the original 05/10/2021 email and below. Comments provided by the Planning Department on <br /> 05/03/2021 should also be addressed prior to resubmitting documents for review; a separate itemized letter should be <br /> provided for Planning's review. <br /> Supplemental Comments: <br /> 3. See the following commens: <br /> a.The door should specify a closer. See Section R302.5.1. <br /> b.The new hallway includes a washer/dryer unit that appears to encroach on the minimum 3-foot hallway width <br /> per Section R311.6,which is not permitted. <br /> c.The new bonus room has been effectively configured to qualify as a bedroom (i.e., egress window,separation <br /> from the garage). Smoke and CO alarms should be provided per Sections R314 and R315. The alarms should be <br /> hardwired and interconnected as required. <br /> 4.The note is note sufficient. A detail specifying the construction should be included. <br /> 6.Sheet A001 does not appear to include a schedule of energy credits. The statement"Alternations do not need to <br /> obtain energy credits" is not correct. This is an addition, defined in the WSEC as adding conditioned space to the <br /> house. Energy credits are required. <br /> 7. Minimum clearances should be dimensioned on the drawings. <br /> 8. See Comment 11 below. <br /> 9. This comment is not sufficient. The required construction should be shown. <br /> 11.This comment has not been addressed. The existing construction of the space being converted must be shown. It is <br /> required to comply with the current code for new construction. Note that this addition was originally constructed in <br /> 1958 and is not expected to comply with the current code requirements without modifications. All construction <br /> requirements, including but not limited to foundations,framing,sill plate anchorage, roof construction, braced wall <br /> panels,and framing fasteners,should be specified. See Sections R102.7 and R102.7.1. <br /> 12.The minimum dimensions for the stairs should be specified. Stairs should comply with Section R311.7. The stairs <br /> should not encroach on the minimum 3-foot hall width per Section R311.6. <br /> 1 <br />