Laserfiche WebLink
• • , <br /> Structural Design Criteria _' <br /> Building Code: 2018 International Building Code <br /> Building Department: City of Everett <br /> Materials Criteria <br /> Concrete(28 Day Strength): <br /> Walls and Columns F'c= 4,000 PSI. <br /> Post-tensioned Slabs Pc= 5,000 PSI <br /> Reinforcing Steel: <br /> Grade 60 Fy= 60,000 PSI <br /> Masonry(Hollow CMU Grade N): <br /> Design Strength F'm= 2,000 PSI <br /> PT Deck Superimposed Loads <br /> Gravity: Comments <br /> Flooring 2.5 psf <br /> Partitions 11.0 psf <br /> 5/8"GWB 2.8 psf <br /> Sprinklers 3.0 psf <br /> Lights,ducts 0.7 psf <br /> Miscellaneous 1.0 psf <br /> Total:l 21.0 psf I LL=100 psf <br /> f <br /> Quantum Consulting Engineers LLC Project: Peninsula Apartments. Date: 3/17/23 Job,No: 21533.01 <br /> 1511 Third Avenue,Suite 323 Designer: SKK Sheet 2 <br /> bow Seattle,WA 98101 Client: Skotdal Checked By: <br /> t k \ <br />