Laserfiche WebLink
aaa <br /> ■ <br /> Itt <br /> Foundation System <br /> Installation In ,. s for Wind Zone 1, 4 ' i , 4By Tie Down. �� oFwasy <br /> �" Updated: 8I910•, ,`.,\.• •,`\y 1,.-� y. '.. 1w. ' �• <br /> • Easy installation •,-"',, i u, ��8 o J30i ti4 kJ <br /> • Stabilizer plates and diagonal frame tie ` ',•s N'p - USSR t S�� '�� <br /> are not required in most set-ups !� T, -• r - . ONALE <br /> • Longitudinal stabilization is easily added _ • ''.. 4 4 <br /> with Tie Down's LSD strut kit. <br /> ` <br /> • Heavy galvanized coating' on bracketrii ;`� r�; "" <br /> and struts. , .:r. ;= _ <br /> REQUIREMENTS r' ~-'`� <br /> • Install in any type of soil, _ -; --- <br /> 4B(175-275 lbs.) or better. • "' <br /> a Maximum vertical projection at sidewall - <br /> is 9'. Higher walls may be used when the t " ;y <br /> design loads are adjusted accordingly. `: -`. <br /> • Main rail spacing must be 75.5" -99.5" ,r,,. -•" <br /> • Additional vertical anchor ties that are X12 <br /> unique to a home's design may be required --- t ' <br /> Ground S stern _ <br /> by the home manufacturer. These locations y �_ <br /> may include shear walls, marriage line ridge (For Block or Steel Pier) <br /> beam support posts, and rim plates. The <br /> longitudinal component of the Xi2 system - <br /> replaces end frame ties. Check manufacturers ._ <br /> set-up requirements. --`'`- t.r, <br /> .s 'tiA <br /> • Maximum pier height is 48". `~� j <br /> • Systems must be placed as evenly as _.y %= <` <br /> possible, no more than 10'from end of home. .c -- h` <br /> • Additional systems may be needed for roof �� �° l�` <br /> slopes greater than 20 degrees, (4.37" in 12" ,�r-- <br /> r.. , <br /> Pitch) See Page 4. Xi2 Ground System ` <br /> • Two systems designed to work in conjunction with Longitudinal Stabilization <br /> with each other. (One Strut for Wind Zone I <br /> • Wind Zones II & Ill requires sidewall anchors. Two Struts for Wind Zones II& Ili) <br /> Check manufacturers requirements. <br /> " Xi2 components exceed HUD code 3280.307g 'Anchoring equipment exposed to weathering shall have a <br /> resistance to weather deterioration at least equivalent to that provided by a coating of zinc on steel of not <br /> less than 0.30 ounces per square foot of surface coating....' <br /> ,1) <br /> M <br /> TIE DOWN ENGINEERING • 590.1 Wheaton Drive • Atlanta GA, 30336 TIE o <br /> www.tiedown.com • (404) 344-0000 • FAX(404) 349-0401 DOWN <br /> CNGINIFRING <br /> i � <br /> Received i lee Oct. '8. i :44R!M <br />