My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2024-02-16
>
Address Records
>
75TH ST SE
>
1318
>
1318 75TH ST SE 2024-02-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2024 3:29:58 PM
Creation date
2/16/2024 3:26:57 PM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Soniya Moon <br /> Blue Moon Realty LLC <br /> Plan Check Number: B2201-048, First Building Review <br /> April 20, 2022 <br /> 2. The proposed project includes structural work. Structural drawings should be submitted that <br /> include framing plans, sections, details, construction schedules, fastening schedules, materials <br /> requirements, general notes, etc. The drawings should substantiate compliance with the <br /> prescriptive requirements of the IRC. Where a structural design is performed per Section <br /> R301.1.3, structural drawings and calculations should be prepared by a professional engineer <br /> licensed in the state of Washington; the drawings and calculations should bear the seal and <br /> signature of the engineer. See RCW Sections 18.43.010, 18.43.020, and 18.43.070 and IRC <br /> Sections R106.1.1 and R301.1. <br /> 3. Please provide Foundation plans, sections, and/or details showing any new footings and any <br /> below-grade walls. The foundation material(s) should be clearly specified. The plans should <br /> specify the type, size, length, width, thickness, and height of all parts of the foundation. Clearly <br /> indicate locations of all required hold downs. R106.1.1 <br /> 4. The plans appear to show basement retaining walls supporting more than 48 inches of <br /> unbalanced backfill. Retaining wall details should be included in the drawings and calculations <br /> substantiating the design should be submitted for review. See IRC Section R404.1.1. Note that <br /> retaining walls supporting more than 6 feet of backfill height measured to the bottom of the <br /> footing should include an additional seismic lateral earth pressure. IBC 1807.2.2 <br /> 5. See Details 4 and 5 on Sheet All. A drainage system should be specified. See Section R405.1 <br /> for more information. <br /> 6. See Detail 5 on Sheet All. Plans should include notes for the construction of the window well <br /> walls. R106.1.1 <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Rakeeb Khan <br /> Residential Plans Examiner <br /> (425)257-7299 <br /> rkhan@everettwa.gov <br /> S:\RKhan\2022\B2201-048_Rl.docx <br /> O3200 Cedar Street 425.257.8810 ( a.� everetteps@everettwa.gov <br /> Everett, WA 98201 © 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.