Laserfiche WebLink
Global Project Values: <br /> Project Name: SEAWAY FACP REPLACEMENT1 Standby Hours: 24 <br /> Project ID: 05230L Alarm Mins:�5 <br /> Prepared By: JOE SHELDON Derating Factor: 1.2 <br /> • Date: 12/04/2023 Voltage Drop Warning <br /> Threshold%: 10 <br /> Panel ID: I FACP Model: 5808 Add.Fire Alarm Control Panel Max NAC Current: 3.0 Amps <br /> Location: FIRE CONTROL ROOM Volts: 24 VDC Max Panel Current: 6.0 Amps <br /> Ckt.# Circuit Name Qt, Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop <br /> Standby Alarm &Type 1000 Ft. One-Way Ohms EOL <br /> 5808 5808 CTRL Panel 1 0.170 0.365 <br /> SK Photo,Photo-T,PhotoR 5 0.001 0.001 <br /> SK Ion0.000 0.000 <br /> SK Heat,Heat-HT, ROR 0.000 0.000 <br /> SK Beam,Beam-T 0.000 0.000 <br /> SK Duct 0.000 0.000 <br /> SK Acclimate 0.000 0.000 <br /> SK FIRE-CO 0.000 0.000 <br /> SK Control 0.000 0.000 <br /> SK Control-6 0.000 0.000 <br /> SK RelayMon-2 0.000 0.000 <br /> SK Monitor,Minimon 0.000 0.000 <br /> SK Monitor-2 5 0.004 0.004 <br /> SK Monitor-10 0.000 0.000 <br /> SK Pull-SA,Pull-DA 17 0.006 0.006 <br /> SK Relay 5 0.001 0.001 <br /> SK Relay-6 0.000 0.000 <br /> SK Zone 0.000 0.000 <br /> SK Zone-6 0.000 0.000 <br /> SK Isolator Module 0.000 0.000 <br /> B224B1 Isolator Base 0.000 0.000 <br /> B200SR Sounder Base 0.000 0.000 <br /> B200S Intelligent Sounder Base 0.000 0.000 <br /> B200SR-LF Low Freq Sounder Base 0.000 0.000 <br /> B200S-LF Low Freq Sounder Base 0.000 0.000 <br /> B224RB Relay Base 0.000 0.000 <br /> RTS151 Magnetic Remote Test 0.000 0.000 <br /> RTS 151 KEY Key Activated Test 0.000 0.000 <br /> RA100Z Remote LED 0.000 0.000 <br /> 5860 LCD Remote Annunc 0.000 0.000 <br /> 5824 Serial/Parallel Module 0.000 0.000 <br /> 5496 Power Expander 0.000 0.000 <br /> 5895XL Power Expander 0.000 0.000 <br /> 5865-4 LED Annunciator(4G) 0.000 0.000 <br /> 5865-3 LED Annunciator(3G) 0.000 0.000 <br /> 5880 LED Driver Module 0.000 0.000 <br /> 5883 Relay Module 0.000 0.000 #14 Solid 2.52 220 1.11 19.42 4.780 <br /> NAC#1 Notification Appl Circuit 0.000 0.880 #14 Solid 2.52 210 1.06 19.56 4.10% <br /> NAC#2 Notification Appl Circuit 0.000 0.790 #14 Solid 2.52 85 0.43 20.12 1.38% <br /> NAC#3 Notification Appl Circuit 0.000 0.658 #12 Solid 1.59 0.00 20.40 0.00% <br /> NAC#4 Notification Appl Circuit 0.000 0.000 Total Alarm Current(Amps) <br /> Total Standby Current(Amps) 0.183 2.706 Alarm Time In Minutes/60 (5 Mins) <br /> Standby Time In Hours 24 0.083 Total Alarm AH Required <br /> Total Standby AH Required 4.390 0.225 Command Shortcuts <br /> Total Combined AH Required 4.62 . <br /> Multiply By The Derating Factorl 1.20 Configure Circuits Print Page <br /> Minimum Battery AmpHours Required 1 5.54 <br />