Laserfiche WebLink
�1 <br /> TEAM LAND USE INFORMATION _ T_ <br /> OWNER&ADDRESS OF PROPERTY ADDRESS: 617 LEGION DR,EVERETT 98201 DESIGNS <br /> PARCEL NUMBER: 572000-0100 <br /> t, PA7LASWESNEY LEGAL DESCRIPTION Section 8 Township 29 Range 5 Quarter SE- 12041 22ND AVE NE <br /> 70' 1017159th Pl.SE <br /> p.... ,. ,. • Bellevue,Wa.98008 <br /> LEGION PARK ADD TO EVERETT DIN 2- <br /> EMAIL 425351 5943 BLK 000 D-00-LOT 3 EVERETT,SNOHOMIS SEATTLE, WA. 98125 <br /> CONTACT COUNTY,WA. <br /> EMAIL Paula_Quiroga@hotmail.com ZONING: SINGLE FAMILY 206 365 2724 vice <br /> LOT SIZE: 0.22 ACRE <br /> PLANS PREPERATION BUILDING FOOTPRINT: N/A <br /> DRIVEWAY: N/A 206 499 2814 cell <br /> ARETE DESIGN SIDEWALKS: N/A <br /> 1204122nd AVE NE IMPERVIOUS SURFACE N/A <br /> SEATTLE,WA.98125 OPEN SPACE: N/A Iuckeyjo@comcast"net <br /> PH:206 365 2724 FILL(CU.FT.): N/A <br /> CELL:206 499 2814 USE EXCAVATION N/A CONSULTANT STAMP <br /> CONTACT:JOE LUCKEY SPOILS,IMPORT BALANCE N/A <br /> Iuckeyjo@gmail.com <br /> STRUCTURAL ENGINEER BUILDING CRITERIA <br /> BUILDING SETBACKS: FRONT 28 FEET Ii� <br /> BUILDING DEPARTMENT FRONT AVERAGE REAR 25 FEET `' <br /> SIDE 5 FEET N <br /> Co <br /> CITY OF EVERETT ALLOWABLE BUILDING HGT.: 30 FEET �VV7 <br /> 0 <br /> GENERAL CONTRACTOR SEISMIC ZONE: 3 WIND EXPOSURE: A�� ^ <br /> m HOMEOWNER OCCUPANCY GROUP: SINGLE FAMILY H L <br /> PROJECT IN <br /> CONSTRUCTION TYPE: V-B (2018 IRC) <br /> APPROVED ENERGY CODE: EXTERIOR BEARING WALLS: EXISTING CITY ® EVERETT <br /> Office of Community, Planning Sc Economic Development • <br /> INTERIOR WALLS: PER STR. y SePrviice <br /> PRESCRIPTIVE PATH REQUIREMENTS FOR Permit �7 <br /> PLANNING DEPARTMENT GROUP R OCCUPANCY CLIMATE ZONE 58 MARINE 4, FLOOR JOISTS: EXISTING S <br /> 6'-5 3/4" 14'-0" 41'-7 3/4" 8'-2 1/2" <br /> GAS: PER TABLE R402.1.1;INSULATION AND <br /> i i i FENESTRATION REQUIREMENTS BY COMPONENT; ROOFS AT SUBJECT S.F. R-49 OR GREATER <br /> /»� EXISTING HOT WATER TANK' <br /> NAME: ait? DATE: V gXlyf/ HEAT TYPE: DUCTLESS HEAT PUMP <br /> • ENERGY CREDITS;3.4 SHEET A 001 PROJECT#:LEDERADDITION <br /> UNLIMITED GLAZING @ 0.30-"U" BUILDING AREA ANALYSIS DRAWN BY:ARETE' <br /> FOR ALL FOR ALL WINDOWS EXISTING NET NEW(FORMER STORAGE) <br /> e • <br /> HORZ(SKYLT)0.50-"U' EASEMENT(EXISTING) N/A N/A <br /> NEW EXT.DOORS 0.30 FOR GLAZING <br /> FLAT CEILINGS R-49 OR BETTER AT SUBJECT S.F.ONLY MAIN FLOOR: 984 S.F. 200 S.F. 1184 S.F. <br /> VAULTED CEILING R-38 HD; UPPER FLOOR N/A N/A <br /> ' • ABOVE GRADE(OPAQUE)WALLS @ R-21 <br /> .y. :... `• RELEASE DATE <br /> . ENERGY NOTES TOTAL: 1184 S.F. MARK DATE DESCRIPTION <br /> %• D M ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN DECKS/PORCHES: N/A N/A X XX'X' ` <br /> PATIO THE HOUSE SHALL BE RATED AT 1.75 GPM OR LESS.ALL OTHER <br /> D v LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR LESS.B.TO GARAGE 330 S.F. N/A 330 S.F. <br /> - • QUALIFY TO CLAIM THIS CREDIT, <br /> j <br /> us THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION MECH. CODE:BEING SELECTED AND SHALL SPECIFY THE WATER HEATER <br /> • <br /> EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCY WITH DISCRETE FANS AT BATHS,KITCHEN&UTILITY ROOM <br /> DOCUMENTS L�VE y� BEEN rP0. AND SHALL SPECIFY THE MAXIMUM FLOW RATES FOR ALL BATHS=50 CFM OR BETTER SET NOTES <br /> THESE HAVE O . , SHOWERHEADS,KITCHEN SINK FAUCETS,AND OTHER LAVATORY KITCHEN=100 CFM PRINT DATE 7/9/2021 <br /> A0PPO O�V�E_D••FOR THE_ ISSUANCE OF • EXISTING . . FAUCETS UTILITY=50 CFM OR BETTER PRIME 5:11PM <br /> PUBLIC WORKS,MECHANICAL,FIRE GARAGEC 98HOUSE `_i, PROVIDE A MINIMUM OF 75 PERCENT OF PERMANENTLY <br /> SUPPRES¢vS§�ON,�ELE�+CTRICAL OR • N LIGINSHTING FIXTURES IN <br /> PLUMBING PERMITS. • , D , Permit _ LIGHTING SHALL BE HIGH-EFFICACY LAMPS. PR PRIMARY HEATING FOR THE(E)BASEMENT&EXSITNG MAIN FLOOR AND <br /> 330.51 sq ft, M <br /> #: B2104-076 ADDITION AT MAIN FLOOR PROVIDED WITH(E) 92.8% C++ <br /> • HIGH EFFICIENCY HVAC SYSTEM; Q <br /> Site Address: 617 LEGION DR CONNECT TG EXISTING <br /> Owner, SWEENEY P M TRUST PRESCRIPTIVE PATH REQUIREMENTS FOR GROUP R OCCUPANCY Z <br /> Additional Permits Are Required • <br /> : s Tenant [TenName] CLIMATE ZONE 5&MARINE 4, PER TABLE R402.1.1; Q W M <br /> For This Project To Include: App. Date: 4�27�ZO21 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT U v <br /> Proposed Use: RESIDENTIAL ALTERATIONS Cl) o N <br /> Sprinkler64 VENTILATION SYSTEM SUMMARY: CO <br /> Plumbing ElDescription: ADD BATHROOM TO EXTG BONUS RM BY NO CHAHGESE Z z0 CO I— <br /> FiI'"e p hy, CO NVRTG PRTN OF GARAGE ADDITIONAL EXHAUST VENTILATION IS PROVIDED IN BATHROOM LU (u W <br /> Mechanicalal ® aa�}rg€ Alarm _ - - WITH WHISPER HOOD AND THEQUIET VE VENTED WIN AND IN THE DOWS.MAY BE MODIFIED EITH D BY BIDDER DESIGN.AUST e‘ J I- Cl) <br /> Electrical �r CONNECT TO EXISTINGHOT WATER RY 0 0_ r W UI <br /> 70' ; > <br /> Reviewed By,� �'��� . ,� Date:�'�Z�ZOZ./ LL• I— <br /> I CONTINUOUS WHOLE HOUSE VENTILATION USING EXHAUST FANS W V <br /> Off ce Set Job Site Set Fire/Planning Set NO cHANGESE la a <br /> 617 LEGION DR z < <br /> SIT <br /> . **Expose all unapproved work (including Subject To Field Inspection <br /> electrical, mechanical, plumbing, and <br /> • No Site Plan framing systems etc.) installedlaltered 'fi' SHEET NUMBER <br /> OF EVERETT <br /> NI SCALE:1" =10' without permits and inspection approval** REVIEWED FOR PERMIT A 000 <br />