ACCESSORIES • <br /> ogODINE <br /> Table 11.1 - Field Installed Accessories <br /> Model <br /> Feature PTC BTC <br /> m Vertical Deflector Blades-Allows directional discharge air control in the left and right directions. • • <br /> oo• Downward Air Deflector Hoods-Available in 30°,60°,and 90°configurations these deflector hoods provide more <br /> 2 focused air flow control.Refer to page 12 for further details. <br /> 47 Two-Point Suspension Kits-Converts from 4-point suspension to 2-point suspension. • <br /> mFingerproof Fan Guard-Ships installed on unit in place of standard guard(standard on size 110 and smaller). • <br /> Pipe Hanger Adapter Kits-Allows the unit to be suspended by 3/4"pipe from the standard 3/8"holes found in the <br /> c top of the unit. <br /> A Discharge Transition for Polytube-Allows for the connection of polytube(not included)to the discharge of the unit. • <br /> v Blower Enclosure with or without Filter Rack-Totally encases the motor and blower assembly. Optional filters <br /> provide filtering of the air prior to entering the heater. <br /> Belt Guard-Provides protection for building occupants as well as service people from the drive belt and sheaves. • <br /> Natural Gas to Propane Gas Conversion Kit-All required parts to convert a natural gas unit to propane gas. • • <br /> Energy Saver Thermostats-Mounted high and independent of the room stat,this control turns on the unit heater <br /> o fan if high temperatures are sensed,forcing the heated air down,reducing stratification and potentially gas usage. • • <br /> SPDT switch,30°-100°range. 16 amp @ 120V.Honeywell T631A1113. <br /> c <br /> o Single-Stage Room Thermostats-See Table 11.2 for details. • • <br /> Stepdown Transformers-Used to operate units on 208V,230V,460V,or 575V supply voltage.Refer to Table 10.1 . <br /> for further selection details. <br /> Condensate Pump-Used for high lift applications of up to 22'-DiversiTech CP-22 • • <br /> R , Condensate Pump Suspension Kit-Used to suspend/support pump(DiversiTech CP-22)from heater. • • <br /> dv Condensate Treatment-Controls slime growth in pump(DiversiTech CP-22)and downstream drain. • • <br /> R Condensate pH Neutralizing Kit-Reduces acidity of condensate. • • <br /> v o= Recharge Kit for pH Neutralizing Kit-Aggregate material to recharge the pH Neutralizing kit(once per year or every • <br /> 2000 hours). <br /> Horizontal Concentric Vent Kit-Enables horizontal concentric venting. Kit consists of one concentric • <br /> o, adapter,one vent termination screen,and one inlet guard assembly(See Figure 11.1). <br /> o <br /> 'E' Vertical Concentric Vent Kit-Enables vertical concentric venting. Kit consists of one concentric adaptor,one • <br /> combustion air inlet cap,and two vent pipe terminal screens(See Figure 11.2). <br /> Termination screens for horizontal or vertical,2-pipe system terminals.Terminals are by others. • • <br /> Figure 11.1 - Horizontal Concentric Vent Kit Figure 11.2 -Vertical Concentric Vent Kit <br /> VENT Iii <br /> TERMINAL I <br /> ASSEMBLY <br /> INLET 4..._. <br /> PVC TERMINAL �7 \ <br /> VENT TERMINALAL ,- <br /> (ELBOV7 <br /> '41111111111111111111 <br /> F CONNECT OEnNT� •I %� \ <br /> TO UNIT COMBUSTION INLET GUARD \ CONCENTRIC VENT ADAPTER <br /> AIR INTAKE CONNECTION ASSEMBLY 1 <br /> CONCENTRIC VENT ADAPTER <br /> FROM UNIT VENT TO UNIT COMBUSTION AIR <br /> CONNECTION — INTAKE CONNECTION <br /> Table 11.2 - Field Installed Thermostats <br /> Description <br /> Single-Stage WHITE-RODGERS 1C20-101 -1.2 amps @3OVAC,50°-90°F temperature range,0.15 to 1.2 amps adjustable heat anticipator <br /> Room <br /> Thermostats WHITE-RODGERS 1C26-101 -Same as 1C20-101 above except adds Heat/Off/Cool and Fan On/Auto switches <br /> HONEYWELL TH5220D1029 digital non-programmable room stat with switching-range 40-90°F <br /> Duct JOHNSON CONTROLS A350 Electronic Temp Control with Sensor and S350 Stage Adder <br /> Thermostats <br /> (BTC Only) HONEYWELL T678A1015 20 foot capillary tube <br /> 6-170.7 11 <br />