Laserfiche WebLink
SELECTION EXAMPLE - MODEL PTC (PROPELLER UNIT) <br /> `!IVD/NE <br /> Selection Procedure Selection Example(Propeller Unit) <br /> In order to properly select a unit heater it is necessary to have <br /> the following basic information. Selection Example Conditions(Propeller Unit) <br /> 1.Heating output capacity Select a unit heater to meet the following conditions: <br /> Model size output is to be matched against the heat loss to 1. Heating output capacity=166,000 Btu/Hr per design <br /> be replaced. engineer <br /> 2.External static pressure(blower units only) 2. External static pressure=0.0 <br /> The external static pressure(E.S.P.) is determined using the 3. Internal statuic pressure=0.0. No static producing <br /> ASHRAE Guide for duct losses or provided by the design accessories are required. <br /> engineer. 4. Heat exchanger=409 Stainless Steel <br /> 5. Gas Type=Natural <br /> 3.Accessory internal static pressure(transitions,filters, 6. Gas Controls=Single Stage <br /> etc.)(blower units only) 7. Supply Voltage:460V/60Hz/3Ph <br /> The critical accessories are those that add internal static <br /> pressure(I.S.P.)to the unit.Once these items are <br /> determined,the total pressure drop can be determined With the information listed above,the basic model, using the <br /> (if applicable). information in this catalog and the Model Nomenclature shown <br /> 4.Heat exchanger material on page 19,can be selected as shown: <br /> The heat exchanger type is determined by the application. 1.Determine the Model and Input Rating(MBH): <br /> The standard heat exchanger material is aluminized steel. Using the Heating output capacity,the Furnace Input Rating <br /> A 409 stainless steel heat exchanger is recommended when is determined from Table 5.1.The closest model to 166,000 <br /> the combined entering/return air to the unit is below 40°F or Btu/Hr output has an Btu/Hr Input rating of 180,000 Btu/Hr so <br /> in high humidity applications. the Furnace Input Rating= 180.The corresponding model for <br /> 5.Type of fuel a 180 size, propeller, separated combustion unit heater is <br /> Either natural or propane gas determined by the design PTC.The model and size are a PTC180. <br /> engineer. 2.Determination of Heat Exchanger Material: <br /> 6.Gas controls From item#4 in the example,the Heat Exchanger required is <br /> 409 Stainless Steel.Thus,the Heat Exchanger Material=S <br /> Single stage,as determined by the design engineer. from the Model Nomenclature on page 19. <br /> 7.Main power supply voltage to unit 3.Determine the Ignition Type: <br /> The Ignition Type=S from the Model Nomenclature on page 19. <br /> 4.Determine Power Code Required: <br /> Referring to Table 5.2, it can be seen that the supply <br /> voltage from the example conditions is not available(460V). <br /> A transformer kit selected later in this example must be used. <br /> In this instance,from Table 5.2 select the 115V/60Hz/1 Ph <br /> power code(PC)=01 unit. <br /> 5.Determine the control type: <br /> From items#4 and#5 in the example conditions,the gas type <br /> is Natural Gas and controls are Single Stage. From Table <br /> 10.2,we are directed to use Control Code(CC) 11. <br /> 6.Determine the fan guard type: <br /> No specific type of fan guard was specified,so select Fan <br /> Guard=S from the Model Nomenclature on page 23. <br /> At this point we have a full model number of <br /> PTC180SS0111 SBAN <br /> 7.Determination of transformer: <br /> To operate a 115V/60Hz/1Ph unit on 460V/60Hz/3Ph supply <br /> power a unit step down transformer must be selected. By <br /> referring to Table 10.1 we see that a 460V to 115V step down <br /> transformer is required.As noted in the footnote for Table 10.1, <br /> the size can be determined to be 1.0kVA from Table 5.2. <br /> 6-170.7 13 <br />