M ieroMetl Date: Weights: Units: WHC 060H Part Number: <br /> 7/30/2019 146Ibs/66.23kg ECD-PRCCECA-DRZB <br /> Submitted To: talexander@gensco.com Job: Notes: <br /> Economizer-Economizer-Ultra Low Leak Economizer,Vertical Orientation,ReliaTel Controller,Differential Enthalpy Sensor,Belimo Actuator.Painted Rain Hood With Aluminum Filter, <br /> Barometric Relief,All Necessary Panels And Hardware Included.A RTVM Ventilation Module Is Required From Trane Factory When A CO2 Sensor Is Combined With Any Of The Following... <br /> Multi-Speed,VAV,Or Zone Sensor. <br /> Compliant Economizer: <br /> 1. Title 24:Economizers meet California Energy Commission Title 24-2013/2016 prescriptive section 140.4(damper leakage etc.),and when used with ReiiaTelP'controls and field <br /> supplied Tracer TD-5 Display Module,meet mandatory section 120.2.i for Fault Detection and Diagnostic requirements. <br /> 2. ASHRAE 90.1:Economizers meet ASHRAE 90.1-2013/2016 damper leakage requirements,and meet 2016 Fault Detection and Diagnosis requirements when used with ReliaTel1A9 <br /> control and field supplied Tracer TD-5 Display Module control system. <br /> 3. IECC:Economizers meet IECC 2012,IECC 2015,IECC 2018 for outside air,return air,and relief damper(when provided)leakage requirements,and when used with ReliaTel"'" <br /> controls and field supplied Tracer',"TD-5 Display Module control systems meet IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements.Note:IECC 2015 and <br /> IECC 2018 requires differential return air sensor,which must be ordered separately. <br /> 4. AMCA:Outside air and return air(volume)dampers are AMCA Class 1A rated at 1"w.g.Refer to MicroMetl NS1 catalog sheet on web site for details.Relief air dampers(when <br /> provided)are also AMCA rated.Refer to GR1 series catalog sheet on web site for details. <br /> Features: <br /> • Gear driven design for trouble-free operation,eliminating slippage and binding associated with standard linkage. AIR <br /> UMW <br /> • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. rrro <br /> • Rainhood is sloped for water run-off. <br /> OSP <br /> • Power exhaust options available. mo„mmv <br /> no oomvo °aoo <br /> • Logic wiring is field supplied and installed between the commercial 2 stage thermostat and HVAC low voltage terminal board. e,°;';,;o�•,,,°o.°9 <br /> MicroMeti Corporation <br /> certifies that the models <br /> GR1 and NS1 shown <br /> herein are licensed to bear <br /> the AMCA Seal. <br /> The ratings shown are <br /> based on tests and <br /> procedures performed in <br /> accordance with AMCA <br /> Publication 511 and <br /> comply with requirements <br /> of the AMCA Certified <br /> Ratings Programs. <br /> The AMCA Certified <br /> Ratings Seal applies <br /> to Air Leakage and Air <br /> Performance ratings. <br /> The Information contained in this drawing is the sole property of Micrometl Corporation.Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. <br /> Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC••Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800 <br />