My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3120 COLBY AVE 2023 Plans 2024-02-20
>
Address Records
>
COLBY AVE
>
3120
>
Plans
>
3120 COLBY AVE 2023 Plans 2024-02-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2024 2:45:11 PM
Creation date
2/20/2024 2:44:24 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3120
Permit
K2306-010
Year
2023
Notes
ADDITION OF 32 HEADS NORTH END OF BLDG, 2 UNITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Bulletin 135 April 2021 <br /> Noi Reliabit Model F1 Res Series Glass Bulb <br /> Residential Sprinklers <br /> cULus Listed <br /> Features Important Note: Model D wrench and Model GFR2 wrench <br /> are no longer compatible with this product. Model W2 (non- <br /> • cULus Listed Residential Sprinklers recessed)and Model W4 (recessed,concealed) are required. <br /> • Available in pendent and horizontal sidewall orientations <br /> • Decorative finishes available, including recessed <br /> escutcheons and conical concealed cover plates <br /> Product Description ; ; <br /> Model F1 Res Series sprinklers are residential sprinklers with a 1 <br /> 3 mm glass bulb operating element.A variety of K-Factors as <br /> well as recessed and conical concealed options are available as - <br /> detailed in this Bulletin. <br /> The F1 Res Series sprinklers are specially engineered for fast <br /> thermal response to meet the requirements of UL 1626.They are <br /> intended for installation in accordance with NFPA 13, 13R, and <br /> 13D. i <br /> Application <br /> The Model F1 Res Series sprinklers cULus Listed Residential <br /> sprinklers are intended for use in accordance with NFPA <br /> 13, NFPA 13R,or NFPA 13D.The Model F1 Res residential <br /> sprinklers are cULus Listed for use in residential occupancies <br /> and residential portions of any occupancy,where permitted by the design density shall be a minimum of 0.1 gpm/sf(4.1 mm/ <br /> NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA min), but in no case shall the flow and pressure be less than the <br /> 13D applications,the design flow and pressure shall not be minimum flow and pressure specified in the Listed Design Criteria <br /> less than the minimum flow and pressure specified in the Listed tables in this bulletin. Model F1 Res Series sprinklers are listed for <br /> Design Criteria tables in this Bulletin. For NFPA 13 applications, use in wet systems only. <br /> Residential Sprinkler Summary Table A <br /> Sprinkler K-Factor <br /> Sprinkler Identification Orientation gpm/psi12 Thread Size Installation Options Max.Coverage Area ft <br /> Model Number(SIN) (Ipm/bar'12) NPT or ISO7-1 x ft(m x m) <br /> Y'i;'1 nrY"-Y-7 5Y1 Y Y Y �f15eTtie" m(Th -Y3. 0 1/2 Pendent or Recessed 16 x16(4.9 x 4.9) <br /> F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) <br /> 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) <br /> F1 Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) <br /> F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed 14 x 14(4.3 x 4.3) <br /> F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed 20 x 20(6.1 x 6.1) <br /> F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed 20 x 20(6.1 x 6.1) <br /> F1Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed 20 x 20(6.1 x 6.1) <br /> F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) <br /> F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) <br /> F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) <br /> F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) <br /> Note: Please note SIN difference between F1Res58 HSW(R3533) and F1Res58 HSWX(RA3533). <br /> www.reliablesprinkler.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.