Laserfiche WebLink
MECHANICAL GENERAL ABBREVIATIONS jo- HVAC GENERAL NOTES-2018 WA STATE <br /> ABBY FULL NAME ABBY FULL NAME ABBY FULL NAME L o <br /> AC AIR CONDITIONING UNIT FCU FAN COIL UNIT NOM NOMINAL 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED.THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO o <br /> AFF ABOVE FINISHED FLOOR FD FIRE DAMPER NTS NOT TO SCALE VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. Z 36 <br /> € AHU AIR HANDLING UNIT FLA FULL LOAD AMPS OBD OPPOSED BLADE DAMPER 2. MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE,INTERNATIONAL BUILDING CODE,INTERNATIONAL O 65 <br /> -o 65 <br /> AL ALUMINUM FOB FLAT ON BOTTOM OD OUTSIDE DIMENSION FIRE CODE 2018 3 WSEC,AND LOCAL CODES AND ORDINANCES. P: %E DO BAS BUILDING AUTOMATION SYSTEM POT FLAT ON TOP POC POINT OF CONNECTION 1LL <br /> BDD BACK DRAFT DAMPER FED FIRE SMOKE DAMPER PRV PRESSURE REDUCING VALVE 3. DU CT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2018 IMC AND WITH CURRENT SMACNA STANDARDS.EARTHQUAKE BRACE ALL DUCTS 28"DIA ANDLARGERWHICH J wli�0 <br /> BI BLACKIRON GALV GALVANIZED PVC POLYVINYLCHLORIDE ARE SUSPENDED MORE THAN I2"BELOW STRUCTURAL SYSTEM. d 0 <br /> BOD BOTTOM OF DUCT GC GENERAL CONTRACTOR REQ'D REQUIRED O 3 E 0 <br /> w 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. (n No a <br /> BOUT BOTTOM GENX GENERATOR EXHAUST RPBA REDUCED PRESSURE BACKFLOW ASSY <br /> BTU BRITISH THERMAL UNITS GLVNL GALVANNEAL <br /> E 2L RTU ROOFTOP UNIT � m <br /> BTUH BRITISHTHERMALONE <br /> UNITS PER HOUR GPM GALLONS PER MINUTE SA SMOKE AIR 5. FLEX DUCTS FLEXSHADUCTS <br /> LL ONLYB USED VAPOR BARRIERNDSH SHALL <br /> EXCEEDASS 12'IN LENGTH <br /> NON-PERFORATED LINER WITH WIRE HELIX.DUCT SHALL BE UL 181 LISTED CLASS Q Z <br /> CAT1 CATEGORY ONE VENT GREASE GREASE DUCT SD SMOKE DAMPER 1 AIR DUCT.FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12'IN LENGTH UNLESS NOTED OTHERWISE. Q Q <br /> SEISMIC RESTRAINT ISOLATORS PER CAT4 CATEGORY FOUR VENT GWB GYPSUM WALL BOARD SL SOUND LINED 0J 0 <br /> AS REQUIRED VIBRATION ISOLATION CFM CUBIC FEET PER MINUTE HP HORSE POWER,HEAT PUMP SM SHEET METAL1 g N J <br /> SCHEDULE fi. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 16730E THE 201818C. U U <br /> CPVC CPVC MATERIAL HVAC HEATING,VENTILATION AND AIR COND. SP STATIC PRESSURE cc a O c as <br /> DB DUCTBOARD HX HEAT EXCHANGER SS STAINLESS STEEL 7. PROVIDE FIRE DAMPERS,SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2018 IBC.PROVIDE CEILING FIRE DAMPERS C LL- p > <br /> E DDC DIRECT DIGITAL CONTROLS ID INSIDE DIMENSION SUSP SUSPENDED WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2018 IBC.INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERSIN ACCORDANCE WITH THE Z na <br /> gDEMO DEMOLISH LAT LEAVING AIR TEMPERATURE T THERMOSTAT MANUFACTURERS INSTRUCTIONS,THE TERMS OF THEIR LISTING,AND THE REQUIREMENTS OF THE CODE. <br /> $ DIFF DIFFUSER LBS POUNDS TOD TOP OF DUCT <br /> DMPR DAMPER LWT LEAVING WATER TEMPERATURE TV TURNING VANES 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR N <br /> ON DOWN MAT MIXED AIR TEMPERATURE TYP TYPICAL WALL. N <br /> E EXISTING MBH ONE THOUSAND BTUH UNO UNLESS NOTED OTHERWISE O <br /> EAT ENTERING AIR TEMPERATURE MCA MINIMUM CIRCUIT AMPACITV VAV VARIABLE AIR VOLUME 9. HVAC EQUIPMENT,VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS.UNLESS SHOWN ON ARCHITECTURAL DRAWINGS,REQUIRED ACCESS PANELS SHALL BE N <br /> EC EGGCRATE MD MOTORIZED DAMPER VD VOLUME DAMPER PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR.MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE IB'XIW. <br /> EER ENERGY EFFICIENCY RATIO MIN MINIMUM VFD VARIABLE FREQUENCY DRIVE Y 8g N <br /> �_ EF EXHAUST FAN M-M MACDONALD-MILLER W DUCT INSULATION WRAP 70. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BV ELECTRICAL CONTRACTOR. 0"�� �yjQ r <br /> ELEV ELEVATION NC NORMALLY CLOSED W/ WITH <br /> ESP EXTERNAL STATIC PRESSURE NIC NOT IN CONTRACT WELD WELDED 11. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE,RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER.RECORD DRAWINGS SHALL INCLUDE AS F.a <br /> EWT ENTERING WATER TEMPERATURE NO NORMALLY OPEN 0 VOLTAGE PHASE 8 DUCT DIAMETER A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT,GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM,INCLUDING SIZES,AND THE TERMINAL <br /> AIR AND WATER DESIGN FLOW RATES. W rtl (:7 ti <br /> Q�0 <br /> 72. OPERATING ANDSYSTEM MAINTENANCEMANUALSAND <br /> LI BETI PROVIDED INFOROTHE IO BUILDINGOWNER THAT INCLUDE ATIONA:SUBMITTAL DATA,EACH <br /> SYSTEM. <br /> STE ADDRESSES OF AT LEAST ONE SERVICE AGENCY,HVAC <br /> CONTROLB SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. <br /> FLEX CONNECTION <br /> HVAC SYSTEM ABBREVIATIONS 13, COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH 2018 WASHINGTON STATE ENERGY CODE(WSEC),COMMERCIAL PROVISIONS AND SECTION G408. <br /> (TYP.) <br /> ABBV FULL NAME ABBY FULL NAME ABBY FULL NAME 14. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER <br /> COMB-GALV COMBUSTION AIR EA AL EXHAUST ALUMINUM DA OUTSIDEAIR <br /> SA SUPPLY AIR LP EA SS EXHAUST SS 304 OA-KOOL OUTSIDE AIR KOOLDUCT 15. DAMPERS USED FOR OUTDOOR AIR INTAKE,EXHAUST,OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT I"W.G.(PER AMCA STANDARD 500D):MOTORIZED DAMPERS:4 <br /> SA-KOOL SUPPLY AIR LP KOOLDUCT EA AL WELD EXHAUST ALUMINUM WELDED RLF RELIEF AIR CFMIS.F.GRAVITY DAMPERS:20CFMIS.F.(40 CFWS.F.FOR DAMPERS SMALLER THAN 24"IN EITHER DIMENSION)PER 2018 WSEC C403.7.8.3. <br /> HORIZONTAL INLINE SA AL SUPPLY AIR LP ALUMINUM EA GALV WELD EXHAUST GALV WELDED RA RETURN AIR r <br /> HJ07 FAN DETAIL SA SS SUPPLY AIR LP SS 30426 EA GLVNL WELD EXHAUST GALVANNEAL WELDED DB DUCTSOARD 16, OUTSIDE AIR INTAKE,EXHAUST,AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED(FAIL CLOSED)PER WSEC,COMMERCIAL PROVISIONS,2018 WSEC SECTION C403.7.8. <br /> SA ALWELD SUPPLY AIR LP ALUMINUM WELDED EA SS WELD EXHAUST SS 304 WELDED FLU-CATi FLUE VENT-CATEGORY I EXCEPT AS ALLOWED BY WSEC. <br /> N.T.S. SA GALV WELD SUPPLY AIR MP GALV WELDED EA BI GREASE EXHAUST GREASE BLACK IRON WELD FLU-CAT4 FLUE VENT-CATEGORY 4 <br /> SA GLVNLWELD SUPPLY AIR MP GALVANNEAL WELD EA GALV GREASE EXHAUST GREASE GALV WELDED FLU-CPVC FLUE VENT-CPVC MATERIAL 17, MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL BE LISTED AND LABELED AS HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT <br /> SA SS WELD WELDED SUPPLY AIR LP SS 30426 EA GALV GREASE EXHAUST GREASE SS 304 WELDED FLU-SS FLUE VENT-SHOP BUILT SS 304 MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723,EXCEPT AS NOTED IN SECTION 602.2.1 OF THE 2018 IMC. <br /> EA EXHAUST AIR MUA MAKE-UPAIR FLU-GALV FLUE VENT-SHOP BUILT GALV <br /> HVAC SYMBOL LEGEND LEGAL DESCRIPTION <br /> DESCRIPTION SYMBOL DESCRIPTION SYMBOL PARCEL NUMBER:00411300501300 w <br /> z <br /> BARE RECTANGULAR SHEETMETAL 14x12 SA FLEX DUCT r PROPERTY ADDRESS:3927 RUCKER AVE,EVERETT,WA 982014833 0 <br /> SOUNDLINE SHEETMETAL(GENERAL NOTES) _14x12 SA-SLEQUIPMENT FLEX ROUND CONNECTOR 24e LEGAL DESCRIPTION:CLIMAX LAND COS ISTADDTO EVERETT BLK 005 D-W-LOTS 13-14-15-16-LG LOT 16 BLK5 <br /> SHEETMETAL W/INSULATION(GENERAL NOTES) 14112-SA-W- EQUIPMENT FLEX RECTANGULAR CONNECTOR 24.24 <br /> BARE ROUND SHEETMETAL 12¢SA SUPPLY DUCT UP/DOWN .H i;`t)C>• W <br /> u <br /> ROUND SHEETMETAL W/INSULATION(GENERAL NOTES) 12¢SA-W EXHAUST DUCT UP/DOWN rily I�%y <br /> BARE OVAL SHEETMETAL 14xl2¢SA RETURN DUCT UP/DOWN ""i 1�`. ff CONTACT LIST <br /> OVAL SHEETMETAL W/INSULATION(GENERAL NOTES) 1412¢SA-W SUPPLYAIR TERMINAL RECTANGULAR AND SQUARE `CEI NAME COMPANY PHONE# EMAIL <br /> EXAMPLE OF EXISTING 14x12 SA RETURN AIR TERMINAL RECTANGULAR AND SQUARE m <br /> HEALTHCARE ACCOUNT MANAGER BREANNA LANGSTON MACDONALD MILLER 208639-7036 BREANNA.LANGSTON@MACMILLER.COM <br /> EXAMPLE OF DEMO EXHAUST AIR TERMINAL RECTANGULAR AND SQUARE ® DESIGN ENGINEER ANDREW EICHENBERGER MACDONALD MILLER 206-768-0004 ANDREW.EICHENBERGER@MACMILLER.COM <br /> ENGINEERING PRINCIPAL TODD BOVEY MACDONALD MILLER 206,379-1770 TODD.BOVEV@MACMILLER.COM <br /> EXAMPLE OF NEW 14.12 SA RADIAL AIR TERMINAL OO <br /> EXAMPLE OF FUTURE(N.I.C.) 14_x12 SA SUPPLY AIR SLOT DIFFUSER FACILITIES DIRECTOR RESH KUMAR THE EVERETT CLINIC 206-794-0135 RAJESH.KUMAR@UHG.COM <br /> FAC TIES AI <br /> TIES SUPERVISOR DON STACEY THE EVERETT CLINIC 425-3256829 DON.STACEY@UHG.COM <br /> EXPOSED QUALITY SHEETMETAL 14.12 SA-Q RETURN AIR SLOT DIFFUSER GENL PROD MANAGER JEFF LAWSON FERRIS-TURNEY 206553-9800 JEFFL@FERRIS-TURNEY.COM Z <br /> 0 <br /> CLEANROOM QUALITY DUCTWORK 1402 SA-C EXHAUST AIR SLOT DIFFUSER <br /> W <br /> DUCT80ARD(1"FIBERGLASS) 1412 SA-DB POINT OF CONNECTION <br /> CONTINUATHON OF ROUND DUCT E7 CENTER LINE `t <br /> CONTINUATION OF RECTANGULAR DUCT THERMOSTAT DRAWING SHEET INDEX - HVAC <br /> AIR FLOW IN SYMBOL CARBON MONOXIDE SENSOR <br /> NUMBER TITLE <br /> AIR FLOW OUT SYMBOL �`� NITROGEN DIOXIDE SENSOR Q TMO.01 SCHEDULES-HVAC <br /> MECHANICAL EQUIPMENT TAG AHU-001 OTHERSENSOR O TM0.01S SITE PLAN <br /> DM2.01 1ST FLOOR PARTIAL DEMO PIAN-HVAC <br /> KEYED NOTE iO ELECTRICAL SWITCH $ TM2.01 1ST FLOOR PARTIAL PLAN-HVAC <br /> ACCESS DOORS MITERED ELBOW WITH TURNING VANES <br /> RATED ENCLOSURE <br /> NOTE:SIZE REFLECTS ACTUAL SHEET METAL DIMENSION AND DOES NOT ACCOUNT FOR INSULATION OR LINING SCOPE OF WORK <br /> DEMO(1)EXHAUST FAN AND ASSOCIATED DUCTWORK,INSTALL(1)NEW EXHAUST FAN AND ASSOCIATED DUCTWORK.REMOVE AND SET ASIDE(2)RETURN AIR GRILLES AND(1)EXHAUST GRILLE.REINSTALL(2) <br /> RETURN AIR GRILLES,(1)INSIDE AND(1)OUTSIDE OF ENDOSCOPY DECONTAMINATION ROOM,AND ADD FLEX DUCT TO CONNECT GRILLES TOGETHER.INSTALL CUSTOM SHEET METAL VAPOR HOOD.REINSTALL <br /> (1)EXHAUST GRILLE AND INSTALL(1)NEW EXHAUST GRILLE INSIDE VAPOR HOOD. <br /> EXHAUST FAN SCHEDULE <br /> UNIT HP PERFORMANCE SPEED CONTROLLED BY OR VOLTI NOISE WT <br /> NO. MFR. MODEL LOCATION CONFIG AREASERVED (WATTS) CFM EXSP RPM BD CONTROL INTERLOCKEDWITH PH dBA LB NOTES <br /> EF-1(E) - - HALL 1]0 INLINE DECON. _ 120/1 - - DEMO HOOD SCHEDULE <br /> REPROCESS <br /> UNIT EXH SUPPLY SUPPLY EXH <br /> DEcoN. NO. UNIT SERVED MFG&MODEL NO. DIMENSIONS CFM CFM ESP COLLAR SIZE COLLAR SIZE NOTES <br /> EF-1 GREENHECK CSP-A700-VG HALL 1]0 INLINE REPROCESS 0.29(143) 380 0.5 1214 Yes - 12011 60 40 1,2,3.4 <br /> VH-1 EF-1 CUSTOM BUILT-UP SHEET METAL 84I42I28 380 - - 7,2 <br /> NOTES: <br /> 1.POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR(E.C.). NOTES: <br /> 2.PROVIDE INLINE BACKDRAFT DAMPER. 1.DECREASE HOOD HEIGHT AS NEEDED TO FIT IN SPACE ABOVE CABINETS <br /> 3.EC MOTOR.PROVIDE MFG'S FAN SPEED CONTROL FOR AIR BALANCING. 2.BUILT WITH X GAUGE STAINLESS-STEEL SHEET METAL .w <br /> 4.FAN OPERATES CONTINUOUSLY 2417/365 <br /> 0 <br /> O <br /> ROOM DESIGN SCHEDULE <br /> ROOM DATA CODE REQUIREMENTS DESIGN QU <br /> FL00 PRESSURE PRESSURE \ <br /> ROOM MIN OUTSIDE <br /> R HEIGH TO MIN OUTSIDE MIN TOTAL 100% HUMIDITY ROOM TEMP TO SUPPLY AIR RETURN AIR EXHAUST AIR HUMIDITY ROOM TEMP <br /> NAME CODE SIMILAR AREA T(FT) (OUSE ADJACENT ACX ACH EXHAUST (%RH) (°F) ADJACENT OUTSIDE ACH AIRFLOW TOTAL ACH (CFM) (CFM) (CFM) (%RH) (°F) <br /> (SF) SPACE SPACE 2 <br /> 161 ENDO DECON REPROCESS ENDOSCOPE CLEANING 205 9.0 1845 NEGATIVE 2 10 YES NR NR -0.01 INWC 2.4 75 12.2 85 0 375 NR 70-75 Z <br /> 1.ROOM AIRFLOW REQUIREMENTS ARE BASED ON ASHRAE 170-2013 AS ADOPTED BY THE 2014 FGI GUIDELINES. O <br /> 2."NR"INDICATES NO REQUIREMENT. U <br /> W <br /> DIFFUSER/GRILLE SCHEDULE (�Z <br /> SYMBOL MANUFACTURER& SIZE TYPE NOTES Z J <br /> MODEL NUMBER _ O r 1 c <br /> Lu <br /> EG-1 - 12x24 - EXISTING v GN <br /> EG-2 SHOEMAKER AL 1x2 T-BAR 12x24 LATTICE T-BAR EXHAUST GRILLE pf�_ <br /> W W�/ <br /> 0LLWN O <br /> JU <br /> ZW'a� �< LL <br /> D��a p <br /> Y� W \ � <br /> UW <br /> UW:, 2 / <br /> W 2 N W U) <br /> >w <br /> US NAVAL EVERETT VE ENGINEER: WST REVISED: <br /> -ION <br /> EICHENBERGER 2022-07-07 <br /> WI TT AVE CNECxED ev. DATE PLOTTED'. <br /> PUGETSOUND PACIFIC VE 2 T BOVEY 2022-07-07 <br /> CAD: ISSUE DATE'. <br /> 5 M HAGBERG 2022-07-07 <br /> U DRAWINGM <br /> D-4101-77221213-00 <br /> 41ST ST <br /> SITE = T M 0.01 <br /> W <br /> 52ND ST SNOHOM H RIVER <br /> W <br /> VICINITY MAP <br /> N NO SCALE <br /> E <br />