Laserfiche WebLink
BUILDING CODE <br />2018 INTERNATIONAL BUILDING CODE <br />DEAD LOAD: 15 psf <br />FLAT ROOF SNOW LOAD: 25 psf <br />SNOW EXPOSURE FACTOR (Ce): 1.1 <br />SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 <br />THERMAL FACTOR (Ct): 1.1 <br />WORKING WE3GHT - 6041bf [UNIT 4WCZ6D481 <br />WIND DESIGN DATA <br />1. BASIC WIND SPEED: 110 MPH <br />2. WIND IMPORTANCE FACTOR (Iw): 1.0 <br />BUILDING CATEGORY: II <br />3. WIND EXPOSURE: B <br />4. Kzt - 1.0 <br />5. INTERNAL PRESSURE COEFFICIENT: NA <br />6. APPLICABLE WIND PRESSURE FOR RTU - 31.4PSF (1609.6.2) <br />SESIMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: 1.0 <br />SEISMIC USE GROUP: 1 <br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 99.3SG <br />3. SEISMIC DESIGN CATEGORY. D <br />4. MECHANICAL & ELECTRICAL COMPONENTS: AIR COOLERS, AIR-COLLED HEAT <br />EXCHANGERS, CONDENSING UNITS, DRY COOLERS, REMOTE RADIATORS, AND OTHER <br />MECHANICAL COMPONENTS ELEVATED ON INTERGRAL STRUCTURAL STEEL OR SHEET <br />METAL SUPPORTS <br />5. ap - 2.5. Rp - 3, OMEGA -JOT - 1.5 (ASCE 7-16 T 13.6-1) <br />6. COMPONENT Fp - 6951bf; CONNECTION Fp - 6951bf <br />FRAMING LUMBER <br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND <br />HEADERS; HEM -FIR NO.2 FOR 2X AND 3X JOISTS, AND STUDS; AND HEM -FIR NO.2 <br />FOR ALL TOP AND BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED <br />ON PLANS). LUMBER TO BE GRADE MARKED PER WCUB SPECIFICATIONS. <br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY <br />DETAILED OR APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. <br />5. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL <br />MEMBERS. <br />6. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16- UNLESS OTHERWISE <br />NOTED. LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO BOX OF THE NOMINAL <br />DIAMETER OF THE LAG BOLT UNLESS OTHERWISE NOTED. <br />7. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION). ALL FOUNDATION <br />BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZEDED, OR Z-MAX COATING TO <br />PROTECT FROM OXIDATION. <br />8. FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE PRESERVATIVELY <br />TREATED WOOD SHALL BE RETREATED IN THE FIELD IN ACCORDANCE NTH AWPA M4. <br />IRC 320.3.1 <br />9. FRAMING ANCHORS FOR JOISTS, PURUNS AND POSTS SHALL BE SIMPSON, OR <br />APPROVED EQUAL APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION. <br />FILL ALL FASTENER HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND <br />QUANTITIES AS SPECIFIED BY THE MANUFACTURER. <br />10. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND <br />NOTES. <br />GFNERAI <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS. <br />2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, <br />BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY <br />ORDINANCES. ANY DEVIATION MUST BE APPROVED PRIOR TO ERECTION. <br />3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY DEVIATION <br />MUST BE APPROVED BY OSHA PRIOR TO ERECTION. <br />4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION <br />PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, <br />STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND <br />LOCAL SAFETY ORDINANCES. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL <br />TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO <br />THE ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE <br />WORK. <br />6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE <br />CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO <br />DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO <br />REVIEW BY THE ENGINEER. <br />7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO <br />ANY OTHER SPECIFIC DETAIL CALLED OUT. <br />S. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE <br />AND LOCATION OF ALL OPENINGS REWIRED FOR DUCTS, PIPES, PIPE SLEEVES, <br />ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR <br />OTHERWISE INCORPORATED IN STRUCTURAL WORK. <br />9. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR <br />HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED <br />MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. <br />10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS <br />GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. <br />WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED <br />TO THE ENGINEER SO THAT THE PROPER REVISIONS MAY BE MADE MODIFICATION TO <br />DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL <br />OF THE ENGINEER. <br />11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE <br />STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL <br />CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, <br />ELEVATIONS, DIMENSIONS AND6�ffrbTAI �p F4C% <br />Structural Design Associates <br />3006 RUCKER AVE <br />Everett, WA 98201 <br />PHONE: 425.339.0293 FAX: 425.252.0916 <br />www.strucdes.com <br />REVIEWED FOR PERMIT <br />Ion <br />w C <br />Z Z C <br />g = <br />a � a <br />JQ <br />CS M LL <br />a � <br />2 (D <br />Lu w <br />Q U) LL Rn <br />J <br />Z Q W <br />.0 N r7 N in <br />Q W O W w 0 <br />or`°�\�=g�" <br />N 00 00 LU 0 US w Z <br />CC (//I <br />N <br />QU 0) O -0 O1 <br />Yk 4� t7 -F, N U <br />`' M °� CL 3 C O C QJ <br />0Q M Q U O <br />�-+ 3 CL O N a)a i7 O I_ a 0 Ir <br />THIS SET OF <br />DRAWINGS SHALL <br />BE ON JOB SITE <br />AT ALL TIMES. <br />��^ 5 COvfAC <br />Additional Permits Are Required irk cJ64 K �a o <br />For This Project To Include: Gr�trrE.0 ra <br />Or s*tEE�• tS . 34 <br />❑ Plumbing ❑ SprinklerroNAL, <br />❑ Mechanical ❑ Fire Alarm JULY 22, 2022 <br />Et Electrical <br />1812 H EWI TT NEW R TU CDrawn heckedB y CICBC <br />Date: 07-20-2022 <br />STRUCTURAL <br />1812 HEWITT AVE. SDA JOB NO. NOTES <br />EVERETT, WA 9576 S- <br />