BUILDING CODE <br />2018 INTERNATIONAL BUILDING CODE <br />ROOF LOAD <br />DEAD LOAD: 15 psf <br />FLAT ROOF SNOW LOAD: 25 psf <br />SNOW EXPOSURE FACTOR (Ce): 1.1 <br />SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 <br />THERMAL FACTOR (Ct): 1.1 <br />WORKING WEIGHT = 6041bf [UNIT 4WCZ6048] <br />WIND DESIGN DATA <br />1. BASIC WIND SPEED: 110 MPH <br />2. WIND IMPORTANCE FACTOR (Iw): 1.0 <br />BUILDING CATEGORY., II <br />3. WIND EXPOSURE: B <br />4. Kzt = 1.0 <br />5. INTERNAL PRESSURE COEFFICIENT: NA <br />6. APPLICABLE WIND PRESSURE FOR RTU - 31.4PSF (1609.6.2) <br />SESIMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: 1.0 <br />SEISMIC USE GROUP: 1 <br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 99.3%G <br />3. SEISMIC DESIGN CATEGORY. D <br />4. MECHANICAL & ELECTRICAL COMPONENTS: AIR COOLERS, AIR-COLLED HEAT <br />EXCHANGERS, CONDENSING UNITS, DRY COOLERS, REMOTE RADIATORS, AND OTHER <br />MECHANICAL COMPONENTS ELEVATED ON INTERGRAL STRUCTURAL STEEL OR SHEET <br />METAL SUPPORTS <br />5. ap = 2.5, Rp = 3, OMEGA -NOT = 1.5 (ASCE 7-16 T 13.6-1) <br />6. COMPONENT Fp = 6951bf; CONNECTION Fp = 6951bf <br />FRAMING LUMBER <br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND <br />HEADERS; HEM -FIR NO.2 FOR 2X AND 3X JOISTS, AND STUDS; AND HEM -FIR NO.2 <br />FOR ALL TOP AND BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED <br />ON PLANS). LUMBER TO BE GRADE MARKED PER WCLIB SPECIFICATIONS. <br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY <br />DETAILED OR APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. <br />5. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL <br />MEMBERS. <br />6. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS OTHERWISE <br />NOTED. LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% OF THE NOMINAL <br />DIAMETER OF THE LAG BOLT UNLESS OTHERWISE NOTED. <br />7. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE <br />PRESSURE TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION). ALL FOUNDATION <br />BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZEDED, OR Z-MAX COATING TO <br />PROTECT FROM OXIDATION. <br />8. FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE PRESERVATIVELY <br />TREATED WOOD SHALL BE RETREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. <br />IRC 320.3.1 <br />9. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, OR <br />APPROVED EQUAL APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION <br />FILL ALL FASTENER HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND <br />QUANTITIES AS SPECIFIED BY THE MANUFACTURER. <br />10. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND <br />NOTES. <br />GENERAL <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS <br />2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, <br />BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY <br />ORDINANCES. ANY DEVIATION MUST BE APPROVED PRIOR TO ERECTION. <br />3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY DEVIATION <br />MUST BE APPROVED BY OSHA PRIOR TO ERECTION. <br />4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION <br />PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, <br />STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND <br />LOCAL SAFETY ORDINANCES. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL <br />TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO <br />THE ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE <br />WORK. <br />6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE <br />CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO <br />DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO <br />REVIEW BY THE ENGINEER. <br />7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO <br />ANY OTHER SPECIFIC DETAIL CALLED OUT. <br />8. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE <br />AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES, PIPE SLEEVES, <br />ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR <br />OTHERWISE INCORPORATED IN STRUCTURAL WORK. <br />9. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR <br />HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED <br />MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. <br />10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS <br />GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. <br />WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED <br />TO THE ENGINEER SO THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION TO <br />DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL <br />OF THE ENGINEER. <br />11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE <br />STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL <br />CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, <br />ELEVATIONS, DIMENSIONS AND LOCATIONS OF ALL OPENINGS, ETC. <br />Structural Design Associates 1812 HEWITT NEW RTU <br />3006 RUCKER AVE <br />Everett, WA 98201 <br />PHONE: 425.339.0293 FAX: 425.252.0916 1812 H E WI TT AVE. <br />www.strucdes.com E VE R E TT, WA <br />9 CO VIA, <br />A C <br />�w O <br />343 <br />z <br />�s�ONAL E�' <br />J U LY 22, 2022 <br />Drawn By: JIB <br />Checked By: CCC <br />Date: 07-20-2022 <br />SDA JOB NO. <br />9576 <br />STRUCTURAL <br />NOTES <br />S-2.0 <br />