BUILDING CODE
<br />2018 INTERNATIONAL BUILDING CODE
<br />ROOF LOAD
<br />DEAD LOAD: 15 psf
<br />FLAT ROOF SNOW LOAD: 25 psf
<br />SNOW EXPOSURE FACTOR (Ce): 1.1
<br />SNOW LOAD IMPORTANCE FACTOR (Is): 1.0
<br />THERMAL FACTOR (Ct): 1.1
<br />WORKING WEIGHT = 6041bf [UNIT 4WCZ6048]
<br />WIND DESIGN DATA
<br />1. BASIC WIND SPEED: 110 MPH
<br />2. WIND IMPORTANCE FACTOR (Iw): 1.0
<br />BUILDING CATEGORY., II
<br />3. WIND EXPOSURE: B
<br />4. Kzt = 1.0
<br />5. INTERNAL PRESSURE COEFFICIENT: NA
<br />6. APPLICABLE WIND PRESSURE FOR RTU - 31.4PSF (1609.6.2)
<br />SESIMIC DESIGN DATA
<br />1. SEISMIC IMPORTANCE FACTOR: 1.0
<br />SEISMIC USE GROUP: 1
<br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 99.3%G
<br />3. SEISMIC DESIGN CATEGORY. D
<br />4. MECHANICAL & ELECTRICAL COMPONENTS: AIR COOLERS, AIR-COLLED HEAT
<br />EXCHANGERS, CONDENSING UNITS, DRY COOLERS, REMOTE RADIATORS, AND OTHER
<br />MECHANICAL COMPONENTS ELEVATED ON INTERGRAL STRUCTURAL STEEL OR SHEET
<br />METAL SUPPORTS
<br />5. ap = 2.5, Rp = 3, OMEGA -NOT = 1.5 (ASCE 7-16 T 13.6-1)
<br />6. COMPONENT Fp = 6951bf; CONNECTION Fp = 6951bf
<br />FRAMING LUMBER
<br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND
<br />HEADERS; HEM -FIR NO.2 FOR 2X AND 3X JOISTS, AND STUDS; AND HEM -FIR NO.2
<br />FOR ALL TOP AND BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED
<br />ON PLANS). LUMBER TO BE GRADE MARKED PER WCLIB SPECIFICATIONS.
<br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY
<br />DETAILED OR APPROVED IN WRITING BY THE STRUCTURAL ENGINEER.
<br />5. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL
<br />MEMBERS.
<br />6. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS OTHERWISE
<br />NOTED. LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% OF THE NOMINAL
<br />DIAMETER OF THE LAG BOLT UNLESS OTHERWISE NOTED.
<br />7. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE
<br />PRESSURE TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION). ALL FOUNDATION
<br />BOLTS AND CONNECTORS MUST BE HEAVY GALVANIZEDED, OR Z-MAX COATING TO
<br />PROTECT FROM OXIDATION.
<br />8. FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE PRESERVATIVELY
<br />TREATED WOOD SHALL BE RETREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4.
<br />IRC 320.3.1
<br />9. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, OR
<br />APPROVED EQUAL APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION
<br />FILL ALL FASTENER HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND
<br />QUANTITIES AS SPECIFIED BY THE MANUFACTURER.
<br />10. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND
<br />NOTES.
<br />GENERAL
<br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS
<br />2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR
<br />THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING,
<br />BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY
<br />ORDINANCES. ANY DEVIATION MUST BE APPROVED PRIOR TO ERECTION.
<br />3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY DEVIATION
<br />MUST BE APPROVED BY OSHA PRIOR TO ERECTION.
<br />4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION
<br />PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY,
<br />STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND
<br />LOCAL SAFETY ORDINANCES.
<br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL
<br />TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO
<br />THE ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE
<br />WORK.
<br />6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
<br />CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO
<br />DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO
<br />REVIEW BY THE ENGINEER.
<br />7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO
<br />ANY OTHER SPECIFIC DETAIL CALLED OUT.
<br />8. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE
<br />AND LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES, PIPE SLEEVES,
<br />ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR
<br />OTHERWISE INCORPORATED IN STRUCTURAL WORK.
<br />9. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR
<br />HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC. ALL SUSPENDED
<br />MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED.
<br />10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS
<br />GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY.
<br />WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED
<br />TO THE ENGINEER SO THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION TO
<br />DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL
<br />OF THE ENGINEER.
<br />11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE
<br />STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL
<br />CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS,
<br />ELEVATIONS, DIMENSIONS AND LOCATIONS OF ALL OPENINGS, ETC.
<br />Structural Design Associates 1812 HEWITT NEW RTU
<br />3006 RUCKER AVE
<br />Everett, WA 98201
<br />PHONE: 425.339.0293 FAX: 425.252.0916 1812 H E WI TT AVE.
<br />www.strucdes.com E VE R E TT, WA
<br />9 CO VIA,
<br />A C
<br />�w O
<br />343
<br />z
<br />�s�ONAL E�'
<br />J U LY 22, 2022
<br />Drawn By: JIB
<br />Checked By: CCC
<br />Date: 07-20-2022
<br />SDA JOB NO.
<br />9576
<br />STRUCTURAL
<br />NOTES
<br />S-2.0