Laserfiche WebLink
EXPANDED HEATING DATA - HEATING BOOST MODE <br />DZI7VSA421B*+ DV48FECD14A* <br />OUTDOOR <br />AMBIENT TEMPERATURE <br />i <br />1 47 <br />1 45 <br />1 40 <br />35 OR LOWER <br />MBh <br />53.4 <br />44.0 <br />42.0 <br />40.6 <br />37.0 <br />50.2 <br />47.1 <br />T/R <br />36 <br />34 <br />32 <br />31 <br />29 <br />29 <br />26 <br />KW <br />4.29 <br />4.19 <br />4.10 <br />4.00 <br />3.95 <br />3.91 <br />3.81 <br />AMPS <br />16.5 <br />16.1 <br />15.7 <br />15.3 <br />15.1 <br />14.9 <br />14.5 <br />Same as normal heating mode <br />COP <br />3.65 <br />3.51 <br />3.37 <br />3.22 <br />3.12 <br />3.04 <br />2.84 <br />Hi PR <br />388 <br />375 <br />363 <br />350 <br />342 <br />337 <br />325 <br />LO PR <br />123 <br />115 <br />108 <br />100 <br />95 <br />92 <br />85 <br />DZI7VSA481B*+ DV48FECD14A* <br />OUTDOOR <br />AMBIENT TEMPERATURE <br />i <br />47 <br />45 <br />40 <br />35 OR LOWER <br />MBh <br />60.5 <br />57.0 <br />53.6 <br />50.2 <br />48.0 <br />46.4 <br />42.6 <br />T/R <br />39 <br />37 <br />35 <br />33 <br />32 <br />31 <br />28 <br />KW <br />5.17 <br />5.04 <br />4.91 <br />4.78 <br />4.71 <br />4.65 <br />4.52 <br />AMPS <br />20.3 <br />19.7 <br />19.2 <br />18.6 <br />18.3 <br />18.0 <br />17.5 <br />Same as normal heating mode <br />COP <br />3.43 <br />3.32 <br />3.20 <br />3.08 <br />2.99 <br />2.92 <br />2.76 <br />Hi PR <br />403 <br />390 <br />377 <br />364 <br />356 <br />351 <br />338 <br />LO PR <br />131 <br />123 <br />115 <br />107 <br />102 <br />99 <br />91 <br />DZI7VSA601B*+ DV60FECD14A* <br />OUTDOOR <br />AMBIENT TEMPERATURE <br />.i <br />i <br />ORLOWER <br />MBh <br />72.1 <br />67.9 <br />63.7 <br />59.7 <br />57.0 <br />55.1 <br />50.4 <br />T/R <br />39 <br />37 <br />35 <br />33 <br />32 <br />31 <br />28 <br />KW <br />6.50 <br />6.30 <br />6.11 <br />5.92 <br />5.80 <br />5.72 <br />5.53 <br />AMPS <br />25.6 <br />24.8 <br />23.9 <br />23.1 <br />22.6 <br />22.3 <br />21.4 <br />Same as normal heating mode <br />COP <br />3.25 <br />3.16 <br />3.06 <br />2.95 <br />2.88 <br />2.82 <br />2.67 <br />Hi PR <br />413 <br />400 <br />387 <br />373 <br />365 <br />360 <br />346 <br />LO PR <br />128 <br />120 <br />112 <br />104 <br />100 <br />96 <br />88 <br />Calculations are based on 70 "F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) <br />High pressure is measured at the suction service valve (the larger valve). Low pressure is measured at the gauge port connection <br />Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature <br />SS-DZ17VSA www.daikincomfort.com 21 <br />