My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11013 1ST DR SE 2024-03-05
>
Address Records
>
1ST DR SE
>
11013
>
11013 1ST DR SE 2024-03-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2024 11:50:27 AM
Creation date
2/21/2024 10:58:09 AM
Metadata
Fields
Template:
Address Document
Street Name
1ST DR SE
Street Number
11013
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT SPECIFICATIONS <br />CAPACITIES (AHRI RATED) <br />Max. Cooling (BTU/h) 17,100 22,800 28,400 <br />34,200 <br />40,000 <br />45,500 54,000 <br />Max. Heating (BTU/h) 17,100 22,800 28,400 <br />34,200 <br />40,000 <br />45,500 54,000 <br />AMBIENT OPERATION RANGE <br />Cooling (°FDB(°CDB)) <br />0 to 115 (-17.8 to 46.1)' <br />Heating (°FDB(°CDB)) <br />-10 to 70 (-23.3 to 21.1) <br />COMPRESSOR <br />Type <br />Swing <br />Swing <br />Swing <br />Swing <br />Swing <br />Swing <br />Swing <br />RLA <br />10.5 <br />15.2 <br />20.0 <br />20.0 <br />27.0 <br />27.0 <br />29.0 <br />CONDENSER FAN MOTOR <br />Horsepower <br />3116 <br />3/16 <br />3/16 <br />3/16 <br />X <br />Y. <br />X <br />FLA <br />2.18 <br />2.18 <br />2.70 <br />2.70 <br />2.50 <br />2.50 <br />250 <br />REFRIGERATION SYSTEM <br />Refrigerant Line Size' <br />Liquid Line Size ("O.D.) <br />%" <br />%" <br />W, <br />W, <br />W. <br />W, <br />W, <br />Suction Line Size ("O.D.) <br />%" <br />%" <br />%e' <br />1%" <br />1%8" <br />1%8" <br />Refrigerant Connection Size <br />Liquid Valve Size ("O.D.) <br />W, <br />W, <br />W, <br />W, <br />W. <br />%.1 <br />%11 <br />Suction Valve Size ("O.D.) <br />%" <br />%" <br />%B" <br />W. <br />8" <br />Valve Connection Type <br />Front Sealing <br />Front Sealing <br />Front Sealiing <br />Front Sealing <br />Front and <br />Front and <br />Front and <br />Back Sealing <br />Back Sealing <br />Back Sealing <br />Refrigerant Charge (oz.) <br />81 <br />81 <br />88 <br />88 <br />118 <br />118 <br />127 <br />Expansion Device <br />EEV <br />EEV <br />EEV <br />EEV <br />EEV <br />EEV <br />EEV <br />Superheat at Service Valve <br />Auto -control <br />Auto -control <br />Auto -control <br />Auto -control <br />Auto -control <br />Auto -control <br />Auto -control <br />Subcooling at Service Valve <br />10±1°F <br />12±1°F <br />14±1°F <br />14±1°F <br />10±1°F <br />8±1°F <br />9±1°F <br />ELECTRICAL DATA <br />Voltage / Phase (60 Hz) <br />208-230/1 <br />208-230/1 <br />208-230/1 <br />208-230/1 <br />208-230/1 <br />208-230/1 <br />208-230/1 <br />Minimum Circuit Ampacityz <br />12.7 <br />17.4 <br />22.7 <br />22.7 <br />34.5 <br />34.5 <br />36.5 <br />Max. Overcurrent Protection' <br />15 <br />20 <br />25 <br />25 <br />35 <br />35 <br />40 <br />Min / Max Volts <br />197/253 <br />197/253 <br />197/253 <br />197/253 <br />197/253 <br />197/253 <br />197/253 <br />Electrical Conduit Size <br />%" <br />%" <br />%" <br />%2" <br />%" or %" <br />%" or %" <br />%" or %" <br />EQUIPMENT WEIGHT (LBS) <br />118 <br />118 <br />127 <br />133 <br />173 <br />173 <br />186 <br />SHIP WEIGHT (LBS) <br />135 <br />135 <br />143 <br />150 <br />185 <br />185 <br />198 <br />Tested and rated in accordance with AHRI Standard 210/240 <br />Z Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes <br />s Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. <br />NOTES <br />• Always check the S&R plate for electrical data on the unit being installed. <br />• Installer will need to supply %" to 1W adapters for suction line connections. <br />• Unit is charged with refrigerant for 15' of %" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. <br />(See table below for allowable line set diameter) <br />UNIT TONS <br />LIQUID <br />ALLOWABLE <br />LINE SET <br />DIAMETER <br />SUCTION <br />®aaaaa�� <br />x Allowable combination <br />" For marked combinations, if normal ambient operation temperature is less than 14°F, limit line set <br />length to 50 ft. max. <br />' For marked combinations, line set length will have a minimum of 25 ft and a maximum of 70 ft. <br />SS-DZ17VSA www.daikincomfort.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.