My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2024 12:23:23 PM
Creation date
2/24/2024 7:42:00 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Figure 1:Typical base wiring <br /> Kidde +(3) <br /> KC2-SB Standard Detector 5 D <br /> Base Installation Sheet <br /> ° <br /> 0 ° <br /> O Z <br /> (1)+ + (2) <br /> (1) IDC_IN from previous device. <br /> (2) IDC-OUT to next device. <br /> (3) To remote alarm indicator.Maximum resistance per wire is 10 0. <br /> Table 1:Base terminals <br /> Number Description Number Description <br /> 1 Not used 4 Remote LED- <br /> Description <br /> 2 IDC-IN/OUT+ 5 Remote LED+ <br /> The KC2-SB standard detector base is used to connect Optica KC2 3 Not used 6 Not used <br /> series conventional detectors to compatible fire alarm initiating device <br /> circuits(IDCs).The detector base also provides terminals for 4 IDC IN- 7 IDC OUT- <br /> connecting a remote alarm indicator. <br /> Installation Specifications <br /> Install this device in accordance with applicable national and local Wire size 12 to 18 AWG(1.0 to 4.0 mm2) <br /> codes,ordinances,and practices. Sizes 16 and 18 AWG are preferred <br /> Refer to technical bulletin P/N 3102650 for location and spacing Screw torque <br /> requirements. Base mounting 18 Ibf-in(2.0 N-m)max. <br /> Terminal 12 Ibf-in(1.4 N-m)max. <br /> Caution: Housing High-impact engineering polymer,white <br /> • Risk of equipment damage.To prevent damage to the base,do Base diameter[1] 4.4 in.(11.18 cm) <br /> not overtighten the base mounting screws or wire terminal screws. Base height from box 0.75 in.(1.9 cm) <br /> Refer to"Specifications"for torque values. <br /> Compatible detectors Optica KC2 series conventional detectors <br /> • Risk of system failure.Electrical supervision requires that the wire Accessories GSA-TS or SIGA-TS4 trim skirt <br /> run be broken at each terminal.Do not loop the field wires around GSA-LED remote alarm indicator <br /> the terminals. <br /> Compatible electrical North American single-gang box <br /> To install the detector base: boxes Octagon box 3-1/2 in.(89 mm)by 1-1/2 in. <br /> 1. Attach the detector base to the electrical box using the screws (38 mm)deep <br /> provided with the electrical box.For compatible electrical boxes, Octagon box 4 in.(102 mm)by 1-1/2 in. <br /> see"Specifications." (38 mm)deep <br /> European single-gang box 75 mm with <br /> 2. Wire the detector base.See Figure 1 and Table 1. 60.3 mm fixing centers <br /> 3. If needed,attach a trim skirt to the detector base.Trim skirts are BESA box with 60.3 mm fixing centers <br /> ordered separately.For compatible trim skirts,see"Specifications." Operating environment <br /> 4. Place the dust cover onto the detector base.Do not remove until Temperature 32 to 120°F(0 to 49°C) <br /> you are ready to install the detector. Relative humidity 0 to 93%noncondensing <br /> [1]5.5 in.(13.97 cm)with GSA-TS trim skirt.6.62 in.(16.81 cm)with <br /> SIGA-TS4 trim skirt. <br /> Contact information <br /> For contact information,see www.kidde-esfire.com. <br /> ©2021 Carrier 1 /1 P/N 3102740-EN•REV 001 •ISS 27JUL21 <br /> III 111111111IIIIIIIIIIII IIIII II 111111111 II II IIIII IIIII III IIIIIIIIIIIII III III <br />
The URL can be used to link to this page
Your browser does not support the video tag.