My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2024 12:23:23 PM
Creation date
2/24/2024 7:42:00 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Kidde Fire Systems Kidde <br /> System Component Datasheet � Fire Systems <br /> Stackable Electric Control Head Kits Effective: October 2019 <br /> with Control Head Monitor K-85-3002 Rev AD <br /> FEATURES <br /> • UL Listed, ULC Listed,and FM Approved for use with systems listed in the Table, "COMPATIBILITY",on page 2. <br /> P/N: 85-486500-010 <br /> ORDER INFORMATION <br /> Part Number Description <br /> 85-486500-010 Kit, Includes: <br /> Electrical Control Head, 24 VDC, Stackable, (Ex. Proof), P/N: 82-486500-010 <br /> Control Head Monitor, P/N 85-100000-100 <br /> (for more information, see data sheet K-85-3000) <br /> Lever Operated Control Head, P/N WK-870652-000 <br /> (for more information, see data sheet K-85-6005) <br /> Note: This kit is UL listed and FM Approved. <br /> 85-486500-020 Kit, Includes: <br /> Electrical Control Head, 24 VDC, Stackable, (Ex. Proof), P/N: 82-486500-010 <br /> Control Head Monitor, P/N 85-100000-100 <br /> (for more information, see data sheet K-85-3000) <br /> Note: This kit is UL listed but Not FM Approved. <br /> Note: Both kits are not suitable for 600/900/1100 Ib ECS Cylinders,ADS Cylinders, Nitrogen drivers, Nitrogen pilot cylinders, <br /> and FE-13 Cylinders. <br /> MO-- <br /> 1.25-18 UNEF-2A <br /> CONNECTION <br /> I <br /> I <br /> I <br /> 1/2"-14 NPT <br /> CONDUIT <br /> CONNECTION <br /> ELECTRIC CONTROL HEAD,PART <br /> NO.486500-01 IS RATED FOR USE <br /> IN HAZARDOUS(CLASSIFIED) <br /> LOCATIONS CLASS 1,DIV.I, <br /> GROUPS C,D AND CLASS II,DIV.II, 5.28" <br /> GROUPS E,F,G BETWEEN <br /> -40F AND 140F.USE CONDUIT <br /> SEAL WITHIN 18 IN.(45-)OF <br /> THIS DEVICE. (8)16 AWG-LEADS <br /> 18"LONG <br /> SWIVEL NUT <br /> 1.25-18 UNEF-2B <br /> CONNECTION <br /> Note: This control head is polarized. Improper wiring will result in failure of this device to operate. <br /> Electric control head, P/N: 82-486500-010, is designed for installation directly on 487 Series Halon and <br /> © Kidde Fire Systems ECSTm agent valves only to a maximum size of 350 lbs. This control head must not be <br /> installed on any other type of halon or agent cylinder valve, nitrogen valve, carbon dioxide cylinder valve, <br /> WARNING FE-13TH cylinder valve or Stop(Directional)valve. Installation of this control head to any other device(e.g., <br /> pressure operated control head)will result in failure of device to operate. <br /> MATERIAL SPECIFICATIONS <br /> Body: Brass Voltage: 24 VDC <br /> Current: 0.2A Continuous Draw <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.