My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2024-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2024 12:23:23 PM
Creation date
2/24/2024 7:42:00 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONEX 1 ELECTRICAL DEVICE LAYOUT <br /> SUPPRESSION CONTROL LEGEND <br /> 4" <br /> sce FIRE ALARM SUPPRESSION CONTROL PANEL <br /> DUAL ACTION MANUAL RELEASE STATION , <br /> FLAG NOTES: sA PUSH BUTTON ABORT SWITCH <br /> NOTE:GENERAL CONTRACTOR IS PHOTOELECTRIC SMOKE DETECTOR <br /> TO SUPPLY A STABLE PLATFORM R SMOKE DETECTOR SHALL BE MOUNTED O <br /> FOR THE SUPPRESSION CYLINDER0 " CH ELECTRIC CONTROL HEAD W/ CONTROL HEAD MONITOR r <br /> BOJ <br /> CEILING O TO THE BASE OF THE 1-5/8UNISTRUT AS <br /> 4„ 201 SHOWN DS KEY MAINTENANCE DISCONNECT SWITCH (NOVEC 1230) <br /> R MOUNT RELAY WITHIN T-0"OF THE ®201 HIGH VOLTAGE CONTROL/MONITORING RELAY ALEXANDER GOW <br /> DETECTOR LOCATION IS D H SCP MR SA SCP.(IF REQUIRED) B4 SUPPRESSION ALARM HORN FIRE EQUIPMENT CO. <br /> ACCEPTABLE HERE H 1436 NW 53RD STREET <br /> SUPPRESSION ALARM LIGHT BLUE LENS <br /> I SEATTLE WA.98107 <br /> _ _ _ _ _ _ _ _ _ _ _ _ _2Z_ _ SECTION DETAIL REFERENCE DEVICE REFERENCE PH:(206)632-2810 <br /> # - DETAIL NUMBER D#-X = ZONE CIRCUIT-DETECTOR ID WWW.GOWFIRE.COM <br /> DETECTOR LOCATIONIS XXX N#-# = NAC CIRCUIT-DEVICE ID <br /> NOT ACCEPTABLE IN XXX — SHEET NUMBER w <br /> HATCHED LOCATION Q <br /> 1'-0"MAXIMUM o <br /> SIDEWALL <br /> WIRE TAG DESCRIPTION <br /> TOP OF DETECTOR <br /> TAG ID CABLE TYPE WIRE DESCRIPTION FUNCTION <br /> ACCEPTABLE HERE z <br /> N THHN BLUE/YL 2 CONDUCTOR, 16 AWG— FPLP NOTIFICATION _O � <br /> 3 <br /> 2Z P THHN RED/ELK 2 CONDUCTOR, 14 AWG- THHN 24VDC POWER <br /> Q N Z R THHN GRN/WHT 2 CONDUCTOR, 14 AWG- THHN SUPPRESSION RELEASE C4 3 <br /> Q <br /> Z THHN BRN/ORG 2 CONDUCTOR, 16 AWG- THHN INITIATING ZONE <br /> ABOVE ACCEPTABLE HEIGHT Z <br /> BELOW ACCEPTABLE HEIGHT <br /> ELECTRICAL INSTALLATION NOTES <br /> 1. ALL INSTALLATION MATERIALS SUCH AS CONDUIT,FITTINGS,BOXES,HANGERS,ETC.,ARE SUPPLIED BY THE <br /> ELECTRICAL CONTRACTOR.MATERIALS FOR"WIRING BY OTHERS"ARE NOT SUPPLIED BY ALEXANDER GOW. <br /> SMOKE DETECTOR MOUNTING DETAIL 2. PANELS,DEVICES,CONDUIT,BOXES,ETC.ARE TO BE MOUNTED AND EXPOSED. ALe 3. EXACT LOCATIONS OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD. <br /> (LING 4. ALL WIRING MUST CONFORM WITH LOCAL CODES. <br /> 5. DETECTOR AND AUDIBLE ALARM DEVICE CIRCUIT POLARITY MUST BE OBSERVED. <br /> coNDUIra•ocTncoNAEBoxoR 6. ALL DETECTOR AND AUDIBLE ALARM DEVICE CIRCUIT WIRES ARE SUPERVISED. N4•sO.BOx WITH RDOND RING 7. WIRING: n,Level IVQUNLESS OTHERWISE SPECIFIED BY THE AUTHORITY HAVING JURISDICTION OR ON THE WIRING DIAGRAMS SUPPLIED r:108282 <br /> FOR THE SPECIFIC INSTALLATION,#16 AWG,COLOR CODED WIRE IS RECOMMENDED FOR THE DETECTOR CIRCUITS. <br /> DETECTOR HEAD DETECTOR BnsE USE#14 AWG FOR THE DC POWER SUPPLY AND AUDIBLE ALARM CIRCUITS,AND USE#14 AWG FOR THE AC POWER <br /> SUPPLY CONNECTIONS. <br /> 8. WIRE SHALL BE SOLID(SINGLE STRAND)COPPER THHN JACKETED,TO SATISFY NFPA,NEC,AND IRI REQUIREMENTS. <br /> 9. CONDUIT SHALL BE EMT.FLEXIBLE CONDUIT SHALL BE LIQUID TIGHT AT THE NOVEC 1230 TANKS. <br /> 10. FOR DETECTOR LAYOUT INFORMATION,REFER TO DRAWING. <br /> 11. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36"OF DIRECT AIR STREAM FROM SUPPLY AIR OUTLETS. Q <br /> 12. REFERENCE SHALL BE MADE TO THE MANUFACTURER'S INSTALLATION,OPERATION,AND MAINTENANCE MANUAL TO 0 J <br /> ASSURE STRICT ADHERENCE TO APPROVED INSTALLATION PRACTICES. N <br /> 00 c:) <br /> ALARM &DETECTION NOTES <br /> ELECTRICAL DEVICE LAYOUTQ z <br /> SCALE: 1/2"= V 1. THE CLEAN AGENT FIRE SUPPRESSION SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 2001. Z <br /> NORTH 2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED. O <br /> TO DETAIL 3. DEVICE LOCATIONS AND CONDUIT ROUTING ARE CONCEPTUAL. FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE <br /> 3 N,2 Z FROM DETAIL 2 WITH APPLICABLE CODES,MANUFACTURER'S RECOMMENDATIONS,AND EQUIPMENT LISTINGS.COORDINATE LOCATIONS W J Q <br /> ,2 Z WITH LIGHTING&HVAC SYSTEM. �J <br /> 1_ 4. ALL CONDUIT IN FINISHED AREAS SHALL BE SURFACE MOUNTED EXCEPT WHERE RUN ABOVE SUSPENDED CEILING OR � J Q Z <br /> N 1 QQ' N 1-4 BELOW SUB-FLOORS. <br /> H N 1-3 5. SIGNALING LINE CIRCUITS SHALL BE CLASS B,INITIATING DEVICE CIRCUITS SHALL BE CLASS B,AND NOTIFICATION U O J Z U <br /> �� H APPLIANCE CIRCUITS SHALL BE CLASS B. W W <br /> N,2 Z NOZZLE N 1-EOL 6. SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 36"FROM SUPPLY AIR DIFFUSERS. Q >— <br /> w <br /> N,2 I,I 2 Z 7. PROVIDE SIGNAGE AT THE SUPPRESSION CONTROL PANEL IDENTIFYING THE POWER PANEL AND CIRCUIT. LU LLJ <br /> DETAIL 1 Z j <br /> SMOKE DETECTORS OEj5 Lu <br /> otcn -i L-j <br /> w w <br /> P zo1 Lry.L � d O � <br /> AEGIS 2.0 <br /> UJ D- b J C/] <br /> Z P'R'3Z R,Z z w � T_ <br /> W � LU a_ <br /> L' <br /> _ w <br /> "SAM DS LL r• <br /> W <br /> P, Z CH � WWO <br /> Q Z ZCD J <br /> a <br /> N U00 �� <br /> DRAWN BY: JOE SHELDON <br /> CONEX 1 DO-2 CONE.} CONEX 4 CONEX 5 CONEX 6 <br /> NOTE:GENERAL CONTRACTOR IS <br /> CHECKED BY: CHRIS SWANN <br /> TO SUPPLY A STABLE PLATFORM <br /> FOR THE SUPPRESSION CYLINDER <br /> PLOT DATE: 6/7/23 <br /> PROJECT NUMBER: 23-7118 <br /> NICET CERTIFICATION <br /> CHRIS SWANN FS-03 <br /> SUPPRESSION CONTROL PANEL DETAIL CERTIFIED ENGINEERING TECHNICIAN <br /> NICEr CERTIFICATION NO.:108282 <br /> 2 NORTH OUTSIDE WALL NORTH INSIDE WALL EXPIRATION DATE:05/01/2024 <br /> SCALE: N.T.S. SCALE: N.T.S. <br /> FIRE <br /> HAZARDS SUP LEVEL <br /> SYSTEMS LEVEL IV <br /> SHEET NUMBER: <br />
The URL can be used to link to this page
Your browser does not support the video tag.