CONEX 1 ELECTRICAL DEVICE LAYOUT <br /> SUPPRESSION CONTROL LEGEND <br /> 4" <br /> sce FIRE ALARM SUPPRESSION CONTROL PANEL <br /> DUAL ACTION MANUAL RELEASE STATION , <br /> FLAG NOTES: sA PUSH BUTTON ABORT SWITCH <br /> NOTE:GENERAL CONTRACTOR IS PHOTOELECTRIC SMOKE DETECTOR <br /> TO SUPPLY A STABLE PLATFORM R SMOKE DETECTOR SHALL BE MOUNTED O <br /> FOR THE SUPPRESSION CYLINDER0 " CH ELECTRIC CONTROL HEAD W/ CONTROL HEAD MONITOR r <br /> BOJ <br /> CEILING O TO THE BASE OF THE 1-5/8UNISTRUT AS <br /> 4„ 201 SHOWN DS KEY MAINTENANCE DISCONNECT SWITCH (NOVEC 1230) <br /> R MOUNT RELAY WITHIN T-0"OF THE ®201 HIGH VOLTAGE CONTROL/MONITORING RELAY ALEXANDER GOW <br /> DETECTOR LOCATION IS D H SCP MR SA SCP.(IF REQUIRED) B4 SUPPRESSION ALARM HORN FIRE EQUIPMENT CO. <br /> ACCEPTABLE HERE H 1436 NW 53RD STREET <br /> SUPPRESSION ALARM LIGHT BLUE LENS <br /> I SEATTLE WA.98107 <br /> _ _ _ _ _ _ _ _ _ _ _ _ _2Z_ _ SECTION DETAIL REFERENCE DEVICE REFERENCE PH:(206)632-2810 <br /> # - DETAIL NUMBER D#-X = ZONE CIRCUIT-DETECTOR ID WWW.GOWFIRE.COM <br /> DETECTOR LOCATIONIS XXX N#-# = NAC CIRCUIT-DEVICE ID <br /> NOT ACCEPTABLE IN XXX — SHEET NUMBER w <br /> HATCHED LOCATION Q <br /> 1'-0"MAXIMUM o <br /> SIDEWALL <br /> WIRE TAG DESCRIPTION <br /> TOP OF DETECTOR <br /> TAG ID CABLE TYPE WIRE DESCRIPTION FUNCTION <br /> ACCEPTABLE HERE z <br /> N THHN BLUE/YL 2 CONDUCTOR, 16 AWG— FPLP NOTIFICATION _O � <br /> 3 <br /> 2Z P THHN RED/ELK 2 CONDUCTOR, 14 AWG- THHN 24VDC POWER <br /> Q N Z R THHN GRN/WHT 2 CONDUCTOR, 14 AWG- THHN SUPPRESSION RELEASE C4 3 <br /> Q <br /> Z THHN BRN/ORG 2 CONDUCTOR, 16 AWG- THHN INITIATING ZONE <br /> ABOVE ACCEPTABLE HEIGHT Z <br /> BELOW ACCEPTABLE HEIGHT <br /> ELECTRICAL INSTALLATION NOTES <br /> 1. ALL INSTALLATION MATERIALS SUCH AS CONDUIT,FITTINGS,BOXES,HANGERS,ETC.,ARE SUPPLIED BY THE <br /> ELECTRICAL CONTRACTOR.MATERIALS FOR"WIRING BY OTHERS"ARE NOT SUPPLIED BY ALEXANDER GOW. <br /> SMOKE DETECTOR MOUNTING DETAIL 2. PANELS,DEVICES,CONDUIT,BOXES,ETC.ARE TO BE MOUNTED AND EXPOSED. ALe 3. EXACT LOCATIONS OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD. <br /> (LING 4. ALL WIRING MUST CONFORM WITH LOCAL CODES. <br /> 5. DETECTOR AND AUDIBLE ALARM DEVICE CIRCUIT POLARITY MUST BE OBSERVED. <br /> coNDUIra•ocTncoNAEBoxoR 6. ALL DETECTOR AND AUDIBLE ALARM DEVICE CIRCUIT WIRES ARE SUPERVISED. N4•sO.BOx WITH RDOND RING 7. WIRING: n,Level IVQUNLESS OTHERWISE SPECIFIED BY THE AUTHORITY HAVING JURISDICTION OR ON THE WIRING DIAGRAMS SUPPLIED r:108282 <br /> FOR THE SPECIFIC INSTALLATION,#16 AWG,COLOR CODED WIRE IS RECOMMENDED FOR THE DETECTOR CIRCUITS. <br /> DETECTOR HEAD DETECTOR BnsE USE#14 AWG FOR THE DC POWER SUPPLY AND AUDIBLE ALARM CIRCUITS,AND USE#14 AWG FOR THE AC POWER <br /> SUPPLY CONNECTIONS. <br /> 8. WIRE SHALL BE SOLID(SINGLE STRAND)COPPER THHN JACKETED,TO SATISFY NFPA,NEC,AND IRI REQUIREMENTS. <br /> 9. CONDUIT SHALL BE EMT.FLEXIBLE CONDUIT SHALL BE LIQUID TIGHT AT THE NOVEC 1230 TANKS. <br /> 10. FOR DETECTOR LAYOUT INFORMATION,REFER TO DRAWING. <br /> 11. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36"OF DIRECT AIR STREAM FROM SUPPLY AIR OUTLETS. Q <br /> 12. REFERENCE SHALL BE MADE TO THE MANUFACTURER'S INSTALLATION,OPERATION,AND MAINTENANCE MANUAL TO 0 J <br /> ASSURE STRICT ADHERENCE TO APPROVED INSTALLATION PRACTICES. N <br /> 00 c:) <br /> ALARM &DETECTION NOTES <br /> ELECTRICAL DEVICE LAYOUTQ z <br /> SCALE: 1/2"= V 1. THE CLEAN AGENT FIRE SUPPRESSION SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 2001. Z <br /> NORTH 2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED. O <br /> TO DETAIL 3. DEVICE LOCATIONS AND CONDUIT ROUTING ARE CONCEPTUAL. FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE <br /> 3 N,2 Z FROM DETAIL 2 WITH APPLICABLE CODES,MANUFACTURER'S RECOMMENDATIONS,AND EQUIPMENT LISTINGS.COORDINATE LOCATIONS W J Q <br /> ,2 Z WITH LIGHTING&HVAC SYSTEM. �J <br /> 1_ 4. ALL CONDUIT IN FINISHED AREAS SHALL BE SURFACE MOUNTED EXCEPT WHERE RUN ABOVE SUSPENDED CEILING OR � J Q Z <br /> N 1 QQ' N 1-4 BELOW SUB-FLOORS. <br /> H N 1-3 5. SIGNALING LINE CIRCUITS SHALL BE CLASS B,INITIATING DEVICE CIRCUITS SHALL BE CLASS B,AND NOTIFICATION U O J Z U <br /> �� H APPLIANCE CIRCUITS SHALL BE CLASS B. W W <br /> N,2 Z NOZZLE N 1-EOL 6. SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 36"FROM SUPPLY AIR DIFFUSERS. Q >— <br /> w <br /> N,2 I,I 2 Z 7. PROVIDE SIGNAGE AT THE SUPPRESSION CONTROL PANEL IDENTIFYING THE POWER PANEL AND CIRCUIT. LU LLJ <br /> DETAIL 1 Z j <br /> SMOKE DETECTORS OEj5 Lu <br /> otcn -i L-j <br /> w w <br /> P zo1 Lry.L � d O � <br /> AEGIS 2.0 <br /> UJ D- b J C/] <br /> Z P'R'3Z R,Z z w � T_ <br /> W � LU a_ <br /> L' <br /> _ w <br /> "SAM DS LL r• <br /> W <br /> P, Z CH � WWO <br /> Q Z ZCD J <br /> a <br /> N U00 �� <br /> DRAWN BY: JOE SHELDON <br /> CONEX 1 DO-2 CONE.} CONEX 4 CONEX 5 CONEX 6 <br /> NOTE:GENERAL CONTRACTOR IS <br /> CHECKED BY: CHRIS SWANN <br /> TO SUPPLY A STABLE PLATFORM <br /> FOR THE SUPPRESSION CYLINDER <br /> PLOT DATE: 6/7/23 <br /> PROJECT NUMBER: 23-7118 <br /> NICET CERTIFICATION <br /> CHRIS SWANN FS-03 <br /> SUPPRESSION CONTROL PANEL DETAIL CERTIFIED ENGINEERING TECHNICIAN <br /> NICEr CERTIFICATION NO.:108282 <br /> 2 NORTH OUTSIDE WALL NORTH INSIDE WALL EXPIRATION DATE:05/01/2024 <br /> SCALE: N.T.S. SCALE: N.T.S. <br /> FIRE <br /> HAZARDS SUP LEVEL <br /> SYSTEMS LEVEL IV <br /> SHEET NUMBER: <br />