Laserfiche WebLink
O p5 a <br />0 <br />O WEYERHAEUSER 3" <br />BUILDING TEMPORARY ACCESS ROAD 2 <br />DETAIL 3, o <br />0 <br />D5.01 3 <br />0 <br />BIOSWALE BANKER TANK pro <br />II LIMITS OF STORAGE AREA — — — — — — — — — — — — — - — O <br />II SURCHARGE 0 <br />II <br />II <br />II SD y <br />SID ®ac c° WATE <br />NTER <br />oRFRONT <br />I I w <br />W <br />Al II I --------- ° �. o <br />0 II I <br />II <br />ll `� <br />II I o <br />I I L — 0000 <br />I <br />NEW SEWER PUMP STATION, o <br />SEE DETAILS 1 AND 2 ON D5.01 I <br />S SD <br />n • SS SS SS SS SS S SS SS SS --� SS SS Ss S S SS SS SS SS SS <br />P P P P P P„ P P S S <br />P P P P P P � P P P <br />SEE ELECTRICAL FOR I I P P P P P P Pa a <br />POWER CONNECTION �2 <br />x ° I S POINT OF CONNECTION <br />a ®® ITIE—IN NEW FORCEMAIN SD <br />I TO EXISTING FORCE MAIN ° <br />IN a I I 8 - � �0 <br />n a° <br />�I IIIrjSD <br />LIMITS POTHOLE TO LOCATED EXISTING FORCEMAIN EVERY 20'�a <br />2 OF WORK I WITHIN LIMITS OF PROPOSED SURCHARGE <br />EXISTING GE".� <br />° > c G c--i RESTROOM I I — I — — _ DETAIL 4 o� <br />— — — — — — — — — — — -- D5.02 <br />N f <br />J I / <br />N — -- — --- — — <br />❑ 5C SO PSO PSI---PSO PSO— IT`S S <br />'.o PSOP PSO PSS P 0 PSS PSS F'SS PSS o 8°08°0808 �8 0080 <br />W W W II NJ W W W W W" W W <br />W W W W <br />SS S °W sS SSW W S W W <br />SC <br />® sD I SID J I A17 <br />P P P P P P— P P P P BUILDING: <br />on — — — — — — — — — — — — — — — — — <br />A a TEMPORARY <br />i e a P P �� r P p 3 v ACCESS ROAD 3; <br />I P P P <br />a — SCAL IN FEET <br />IF THIS DRAWING IS NOT 22"x34" SCALE ACCORDINGLY. so 0 50 100 RECORD DRAWINGS <br />PROJECT ENGINEER: SCALE PORT OF EVERETT owc. NO. <br />PND ENGINEERS, INC. IS NOT RESPONSIBLE FOR SAFETY J. KESER NOTED D5.00 <br />p PROGRAMS, METHODS OR PROCEDURES OF OPERATION, OR THE <br />¢ /j CONSTRUCTION OF THE DESIGN SHOWN ON THESE DRAWINGS. DESIGNED BY: DATE: <br />Port Of 3241 E"slake A�er,�eE WHERE SPECIFICATIONS ARE GENERAL OR NOT CALLED OUT, C. WIEST JULY 2022 MILLWRIGHT LOOP ROADS <br />CIP NO. <br />0 ® ® © Seam,,waslwm=98102 THE SPECIFICATIONS SHALL CONFORM TO STANDARDS OF 6-8-008—01 <br />EVERETT 0 7/7/23 JBK RECORD DRAWINGS DRAWN BY CHECKED BY PHASE I 2: 206.624.1387 INDUSTRY. DRAWINGS ARE FOR USE ON THIS PROJECT ONLY <br />,� ENGINEERS, INC. _.pnde gjnee[s _ 01 8/10/22 JBK ADDENDUM 1 AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN G. DEAN C. CASTONA PROJECT PD—WP-2022-07 <br />N P.O. BOX 538 APPROVAL FROM PND. DRAWINGS ARE ALSO NOT TO BE USED UTILITY PLAN N0. <br />EVERETT, WA 98206 DO 7/27/22 JBK ISSUED FOR BID IN ANY MANNER THAT WOULD CONSTITUTE A DETRIMENT APPROVED BY: <br />(425) 259-3164 DIRECTLY OR INDIRECTLY TO PND. <br />N0. DATE BY REVISION SHEEP N0. 44 OF 48 <br />