Laserfiche WebLink
FIRE CODE ORDINANCE Page 10 of 38 <br /> <br />the street or a single access road or private roadway serves more than one building, provision <br />shall be made to clearly identify which driveway or roadway serves the appropriate address. <br /> <br />Table 505.3.1 - Address Numbering Figure Size <br />DISTANCE FROM ROAD OR FIRE LANE MINIMUM SIZE <br />0-100 feet 8”H x 4”W <br />101-150 feet 10”H x 5”W <br />151- feet and up 12”H x 6”W <br /> <br />505.3.2 Individual dwelling/living units. Interior and exterior access doors to individual dwelling <br />/ living units shall be clearly marked. Numbers and/or letters of such units shall be sized to at <br />least four inches. When the address numbers are located on clear glazing such as doors, <br />windows, or lights the numbers shall be white or black to achieve contrast during all lighting <br />conditions. <br /> <br />505.4 Commercial Buildings. New and existing commercial buildings shall have approved address <br />identification complying with sections 505.1 and 505.4.1 through 505.4.2. <br /> <br />505.4.1 Primary address. The size of primary address numbers located on the front of a <br />commercial building shall be determined by the Table 505.4.1. Address numbers at least four <br />inches shall be prominently displayed on rear entrance or access doors. <br /> <br />Table 505.4.1 - Address Numbering Figure Size <br />DISTANCE FROM ROAD OR FIRE LANE MINIMUM SIZE <br />0-50 feet 10”H x 5”W <br />51 -200 feet 12”H x 6”W <br />201 feet and up 14”H x 7”W <br /> <br />505.4.2 Tenant spaces. Interior and exterior access doors to tenant spaces shall have their <br />individual addresses clearly marked with a minimum of four-inch-high numbers and/or letters. <br />Rear entrances or access doors shall also have address numbers and /or letters sized to a <br />minimum of four inches. When the address numbers are located on clear glazing such as doors, <br />windows, or lights the numbers shall be white or black to achieve contrast during all lighting <br />conditions. <br /> <br />C. Section 506.1 of the IFC, entitled “Where required,” is hereby deleted and the following inserted in <br />its place: <br /> <br />506.1 Where required. Where access to or within a structure or an area is restricted because of secured <br />openings or where immediate access is necessary for lifesaving or fire-fighting purposes, the fire code <br />official is authorized to require a key box to be installed in an approved location. Key boxes shall be of <br />the type listed by the Everett Fire Department and approved by the fire code official. <br /> <br />B. Section 507 of the IFC, entitled “Fire Protection Water Supplies,” is hereby deleted and the following <br />inserted in its place: