My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2024-04-12
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 2:16:09 PM
Creation date
3/1/2024 9:56:00 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Free vent area available calculation detail <br />The leakage area during discharge will be: <br />• 334 sq in for the Enclosure Only with the enclosure set up in its Positive Discharge Period Condition, <br />where any dampers or installed PRV were fixed in the position they would assume under +125 Pa. <br />Additional PRV area required detail <br />The Enclosure Only provides 334 sq in of positive venting area. Since this is more than the required total of 206 <br />sq in, this enclosure does not require any additional PRV area to maintain structural integrity and pass the peak <br />pressure procedure in the positive direction. <br />Test Data Appendix- Capacitor Room <br />Enclosure Construction Data <br />The maximum flooded height used in the calculations is 11.1 ft. The equipment was installed in the room, and <br />the top of the rack was measured to be 8.0 ft, so 8.0 ft was taken as the minimum height for protection. Net <br />protected volume used is 5,320 cu ft. Building elevation used is 0 ft, and the elevation correction factor used in <br />the calculations is 1. <br />Total Enclosure Leakage test data <br />Based on measured values, the enclosure alone has an equivalent leakage area of 263 sq in at a reference <br />pressure of 10 Pa. <br />The following table represents the results from the enclosure integrity procedure carried out on the whole <br />enclosure, with all intentional openings sealed. <br />Test conditions <br />, <br />Test date 2023-03-15 Inside temperatureTe [oF] 68 F <br />Outside temperature, <br />Test time 07:05:37 To [oF] 68 F <br />Operator location outside Bias pressure, Pbc [Pa] 0.60 <br />Depressurize Data <br />Pressurize Data <br />Induced pressure [Pa] <br />10.1 <br />50.4 <br />-10.0 <br />-50.0 <br />m <br />Fan Pressure [Pa] <br />224.5 <br />m <br />192 <br />4 tw <br />U tw <br />r- r- <br />Flow [CFM] <br />923 <br />a r- <br />869 <br />oc <br />� oc <br />on <br />C <br />Fan Pressure [Pa] <br />123.5 <br />do <br />r- <br />57.5 <br />oc <br />r; <br />xt oc <br />Page 6 of 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.