My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2024-04-12
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 2:16:09 PM
Creation date
3/1/2024 9:56:00 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RELEASING CIRCUITS <br />The ARIES-SLX control unit has two releasing circuits that can <br />be configured to actuate releasing devices via any of the follow- <br />ing ways: <br />• Single control head or solenoid valve <br />• Two series -supervised, parallel -actuated control heads or <br />solenoid valves. <br />• One Metron actuator <br />• Fenwal initiators <br />These releasing circuits can be used to actuate various Kidde <br />control heads for waterless -extinguishing -system storage con- <br />tainers, or solenoid valves for sprinkler control that are FM <br />Release Panel Group 2. A releasing circuit can actuate an <br />unmatched pair of control heads or solenoid valves because it <br />activates these releasing devices in parallel, not in series. This <br />means that a releasing circuit can activate the control valves for <br />a waterless suppression system and a back-up pre -action - <br />sprinkler system simultaneously which makes efficient use of <br />the control unit's circuitry and increases system reliability by <br />enabling a single action to operate both extinguishing systems. <br />The releasing circuits are protected against inadvertent activa- <br />tion via the main microprocessor by "Triple-R" (for triple redun- <br />dancy) safeguard system. The "Triple-R" system requires that <br />the main microprocessor issue two release commands, of <br />opposite polarity and via separate signaling channels, and that <br />these commands be combined with a signal from the control <br />unit's watchdog timer confirming proper microprocessor opera- <br />tion, in order to activate a release circuit. This triple -redundant <br />release -command requirement ensures that an electrical tran- <br />sient or disturbance that temporarily interferes with the opera- <br />tion of the main microprocessor will not inadvertently activate <br />an extinguishing system. <br />NOTIFICATION -APPLIANCE CIRCUITS <br />The ARIES-SLX control unit has two notification appliance <br />circuits (NACs). Each circuit can provide up to 1.5 Amps @ 24 <br />Vdc for horns, strobes, chimes, or other notification appliances. <br />Power for the notification appliances is fully filtered and regu- <br />lated. Each NAC is programmable, and supports continuous <br />and master -coded outputs for audible devices. The NACs' <br />coded patterns are dynamically adjustable and can be pro- <br />grammed to sound different codes to notify the occupants of <br />progressively -more -serious conditions. <br />Both circuits are supervised, power limited, and are compatible <br />with conventional, UL-Listed, 24-Vdc regulated notification <br />appliances. They can be used with the following Wheelock <br />horns and strobes: <br />• MT Series Multi -Tone Horns and Horn/Strobes <br />• NS Series Horn/Strobes (See Note) <br />• NH Series Horns <br />• RSS(P) Series Strobes (See Note) <br />• Exceder Series Horns, Strobes, and Horn/Strobes (Xenon <br />flashtube models only) <br />Note: Wheelock NS Series Horn/Strobes and Wheelock NH <br />Series Horns cannot be programmed for synchroniza- <br />tion. Horn/strobe combination devices utilizing the <br />appropriate synch protocol have the option to use <br />silenceable horns and non-silenceable strobes. Refer <br />to the horn/strobe manufacturer's installation sheet for <br />details. <br />COMBO CIRCUITS (NAC OR RELEASE) <br />The ARIES-SLX has two combo circuits which can be con- <br />figured as a NAC or a release circuit to activate one sole- <br />noid for special -extinguishing -system actuation or pre- <br />action/deluge sprinkler -system actuation. When configured <br />for release, the circuit is protected against inadvertent acti- <br />vation via the main microprocessor by the Triple-R safe- <br />guard feature. <br />ON -BOARD RELAYS AND AUXILIARY POWER <br />The ARIES-SLX has four Form-C relays. Three of the four <br />relays are user -programmable for any system condition and the <br />fourth relay is dedicated to trouble conditions. Each relay is <br />rated for 1 Amp @ 28 Vdc. <br />Two auxiliary power outputs are provided, each with a 1 amp <br />output. These auxiliary power outputs are user configurable for <br />resettable or continuous power. <br />INTEGRATION WITH SPECIALTY DETECTION <br />SYSTEMS <br />SmartOne loop protocol interface cards enable the ARIES-SLX <br />to seamlessly integrate with specialty detectors. AIR -Intelli- <br />gence Air Sampling Smoke Detectors (ASD) connect via <br />Addressable Protocol Interface Cards (APIC) and report pre - <br />alarms and alarms in a manner analogous to SmartOne smoke <br />detectors. <br />Fixed Temperature Linear Heat Sensor cables (LHS) connect <br />via Addressable Input Modules (AI) and report point alarms. <br />PROGRAMMING <br />The ARIES-SLX Configuration Tool (ACT-SLX) is used to pro- <br />gram the control unit for each individual, site -specific applica- <br />tion. Programming is for control -by -event scenarios, and <br />consists of entering a series of conditional control statements <br />that logically join initiating points to control -unit -based outputs <br />and remote control modules. Each SmartOne field device can <br />be assigned a location message of up to 40 characters via the <br />tool. A USB Device Port is available to connect to a laptop com- <br />puter for application upload. <br />A front panel -activated AutoLearn routine can be executed that <br />will create a general alarm, one input activates all outputs appli- <br />cation to speed the system -configuration process. The more <br />sophisticated Auto -Setup routine allows the system to be auto- <br />matically configured for the typical control scenario utilized by <br />waterless fire -suppression systems. <br />OPTIONAL MODULES: <br />ARIES-SLX NETWORK - NIC AND OCC CARDS <br />The ARIES-SLX networking structure supports a mixture of <br />twisted -wire and fiber-optic interconnections between net- <br />worked control units. The ARIES-SLX can be networked with <br />legacy Fenwal and Chemetron single loop control units which <br />allows the ARIES-SLX to be used as either a service replace- <br />mtn for existing networks or for system expansion. <br />The ARIES-SLX Network Interface Card (NIC) mounts to the <br />control unit's printed circuit board as a "daughter" card and pro- <br />vides peer -to -peer interconnection for up to 32 control units. It <br />supports Class B interconnecting wiring, and acts as a repeater <br />to boost and regenerate the communications signals. It trans- <br />mits and receives messages via the RS-485 format. One NIC is <br />required for each node. <br />
The URL can be used to link to this page
Your browser does not support the video tag.