,. . <br /> data shee AR CO <br /> SWC6 0 1081 <br /> STAND-OFF TWO HOLE STRAP <br /> NO BLOCK FOR CPVC <br /> •For mounting CPVC pipe to wood <br /> •Flared edges help protect CPVC <br /> ti 'Galvanized steel <br /> i -Supplied with #I 0 x I" hex head cap screws <br /> !, 'Complies with the static load requirements of NFPA° 13 <br /> • Suitable for fire protection installations <br /> • Eliminates spacers or backup blocks <br /> � • Easy installation <br /> i <br /> top mount <br /> 'T -- C®US <br /> Designed to mount CPVC pipe horizontally or vertically to wood or composite wood bottom <br /> ;;;;L-----7----\°) <br /> mount <br /> joists with a minimum 3/8"thickness. <br /> Can only be used as a guide on top of beam or on vertical piping. ��-) <br /> May be installed to wood using supplied fastener or into (minimum 18 gauge)steel using two <br /> 1/4"x 1" TEK type screws. <br /> side mount <br /> Provides vertical/lateral restraint and prevents upward movement of the pipe that supplies <br /> pendant fire sprinkler below ceiling. <br /> All sizes can be used as a restrainer in the bottom position. <br /> The 3/4"size only can be used as a restrainer in the top position. 2 <br /> [f_r5" <br /> Installation: Per NFPA 13, 13R and 13D. (see page two) <br /> Fasteners: .i 1 1" <br /> Wood- 3/4"to 3"CPVC Pipe-wood screw-no pre-drill <br /> 3/4"to 2"Copper Pipe-wood screw-no pre-drill <br /> 3/4"to 2"Steel Pipe-1/4"x 1-1/2"lag screw-no pre-drill <br /> Steel- 3/4"to 3"CPVC Pipe-1/4"TEK screw <br /> 3/4"to 2"Copper Pipe-1/4"TEK screw <br /> 3/4"to 2"Steel Pipe-1/4"TEK screw <br /> MAX.HANGER A <br /> NPS A B SPACING <br /> ARGCO 3/4" 2.69" 3.25" 67 <br /> MODEL# 1" 2.94" 3.25" 70" <br /> 2530180 1-1/4" 3.31" 3.25" 79" <br /> 1-1/2" 3.56" 4.5" 82" <br /> 2" 4.06" 5" 94" I <br /> For use as a restrainer in all sizes when attached to the bottom of structural wood members. l4 B "1 <br /> For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members <br /> 11 The information contained herein is produced in good faith and is believed to be reliable but is for guidance only.ARGCO and its agents cannot assume liability or responsibility for results obtained in <br /> the use of its product by persons whose methods are outside or beyond our control.It is the user's responsibility to determine the suitability of any of the products,methods of use,or preparation prior <br /> to use,mentioned in our literature.It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any <br /> of our products. <br /> FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 <br /> OR LOG ONTO WWW.ARGCO.COM <br />