Laserfiche WebLink
Fire Sprinkler Pipi. - <br /> z <br /> Schedule 10 and Schedule 40 Ir <br /> Submittal Data Sheetliti <br /> t ` <br /> FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS <br /> Wheatland's Schedule 10 and Schedule 40 <br /> steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL <br /> C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> In. mm In. mm in. mm lbs./ft. kg/m CRR Lift <br /> Approvals and Specifications <br /> Both products meet or exceed 1% 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 <br /> the following standards: <br /> 1% 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 <br /> • ASTM A135,Type E,Grade A(Schedule 10) <br /> 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 <br /> • ASTM A795,Type E,Grade A(Schedule 40) <br /> 2'% 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 <br /> • NFPA 13 <br /> 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 <br /> Manufacturing Protocols <br /> Schedule 10 and Schedule 40 are subjected 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 <br /> to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 <br /> ensure the highest quality and long-lasting <br /> performance. 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 <br /> 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 <br /> Finishes and Coatings <br /> All Wheatland black steel fire sprinkler pipe •Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. <br /> Up to 6" receives a proprietarymill coating to •The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. <br /> Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). <br /> ensure a clean,corrosion-resistant surface that <br /> outperforms and outlasts standard lacquer <br /> Ecoatings.This coating allows the pipe to be <br /> SCHEDULE 40 SPECIFICATIONS <br /> asily painted,without special preparation. <br /> Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL <br /> black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES <br /> FM/UL requirements for dry systems that meet In. mm In. mm In. mm lbs./ft. kg/m CRR• LIft <br /> the zinc coating specifications of ASTM A795 <br /> or A53.All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 <br /> also UL Listed. 1% 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 <br /> Product Marking 1'/a 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 <br /> Each length of Wheatland fire sprinkler <br /> pipe is continuously stenciled to show 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 <br /> the manufacturer,type of pipe,grade,size •Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. <br /> and length.Barcoding is acceptable as a •The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. <br /> supplementary identification method. Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). <br /> Oc ell 40" <br /> APPROVED <br /> SUBMITTAL INFORMATION <br /> PROJECT: CONTRACTOR: DATE: <br /> ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: <br /> LOCATIONS: • COMMENTS: <br /> 1111, BLACK ❑ HOT-DIP GALVANIZED <br /> WFS-051516 <br /> gE 700 South Dock Street info@wheatland.com <br /> Sharon,PA 16146 wheatland.com Wheatland Tube <br /> P 800.257.8182 Follow us on Twitter: A DIVISION OF ZEKELMAN INDUSTRIES <br /> F 724.346.7260 (i'WheatlandTube <br />