3501 COLBY AVE 2023 Plans 2024-03-07
>
Address Records
>
COLBY AVE
>
3501
>
Plans
>
3501 COLBY AVE 2023 Plans 2024-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2024 1:49:43 PM
Creation date
3/7/2024 1:49:31 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3501
Permit
M2305-064
Year
2023
Notes
P5750 REPLACE EXISTING RTU 3-2
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 1 <br /> PACKAGED GAS/ELECTRIC AC UNIT EQUIPMENT SCHEDULE -. c <br /> MARK LOCATION UNIT COOLING HEATING SOUND ELECTRIC OPERATING BASIS OF DESIGN SERVES REMARKS 03 E- CO <br /> NOMINAL TONS TOTAL CFM OSA CFM ECON CYCLE HP/BHP PERFORMANCE COOLING(STUN) EER SEER INPUT STUN OUTPUT STUN AFUE DBA(DB) VOLTAGE/PHASE MCA MOCP(AMPS)WEIGHT:LEA MANUFACTURER MODEL <br /> E <br /> RTU 3-2 ROOF 2.0 805 80 100% 1/3 24600(AHRI STANDARD 210/240) 12 14 60,000 48,600 81% 66.6 230/1/60 19.1 30 519 'MANE 4YCC4024A10606 1,2,3,4,5,6,7,8,9 ( ) O <br /> REMARKS: �/ <br /> U <br /> 1.PROVIDE 100%OA ECONOMIZER 6.SUPPLEMENTARY HEAT LOCKOUT ABOVE 40 DEG F PER 2018 WSEC C403.1.2. c TH7 V <br /> 2.PROVIDE LOW-LEAK SHUTOFF DAMPERS. 7.CONNECT TO EASING TEMPERATURE CONTROL WIRING. tom/) 0 <br /> O <br /> 3.CONNECT TO EASING GAS PIPING, B.UNITHAS 2 STAGES OF COOLING DIRECTLY CONTROLLED BY SPACE TEMPERATURE PER C403.5.1. CO � � <br /> SE 4.ELECTRICAL BY OTHERS. 9.ECONOMR HIGH LIMIT SHUTOFF CONTROL WHEN OUTSIDE AIR IS 75 DEGREES OR ABOVE. <br /> 5.WEIGHT INCLUDES CURB ADAPTER AND OTHER INSTALLED OPTIONS. V <br /> 1:3 <br /> C CU <br /> N <br /> OD i <br /> wp v <br /> Pp@CG o <br /> Attachment ICIC (' <br /> NIIIIIIIIIIII <br /> Unit to Adaptor Curb CT, <br /> Self Tap screws- --- 24"oc perimeter <br /> Adaptor curb to m <br /> Existing Curb_tong <br /> wood screws @ 24" <br /> oc <br /> 3132 N.E.1333T <br /> �•'� (MI Existing 21"Tit Seattle.PO Boxt27W325-0423 <br /> • <br /> `--1------.' <br /> ..,�.'l i i �1....�.....; /s trusses Seattle,Washin9ion 93165-1473 <br /> I :- ( : (206)367-2500 <br /> Fax(206)366-6856 <br /> (E)RTU (E)RTU RTU ATTACHMENT DETAIL l PSRMEML809C6 <br /> , ,/ • <br /> SCALE: NTS <br /> // -. <br /> I <br /> F // ,... <br /> ad <br /> \\ \\X 19- <br /> 00 <br /> zFW <br /> > a <br /> I//' // <br /> INSTALL REPLACEMENT RTU <br /> ©� CURB <br /> OELO(E)RTU Q 6 ON 1O ADAPTER <br /> {SEE RTU ATTACHMENT DETAL) <br /> \\ .1 <br /> WOK NO PUGEr SOL. <br /> i0 ii \\ -• u." swx:ro <br /> 17 SEMI., ,l•usn000ETO <br /> N. <br /> uroroOK wuacesPIRAICAIION OR USE° TM'MS 1•0F.. <br /> (E)DWAUST FAN (E)EXHAUST FAN <br /> .../- <br /> 76. <br /> try, l'- T -- 1 <br /> // _ // I <br /> --_--,. No. RevlsbNlssue Date <br /> ommay 1 <br /> C.STONE <br /> SI10(2023 <br /> Load Tech <br /> . get;yp,�,% ap.+yy.�1�..« �t HRYCIUK <br /> _ a ..t., ., OJ9" �a.RETT D510/2023 a s <br /> HVAC ROOF PLA\ — DEMO HVAC 'OOF PLA\ — \ EW WORK t . ,.., P7 - <br /> FAR PERMIT N.H. MZ.O <br /> SCALE: 1/8"=1'-0" �� SCALE: 1/8"=1'-0" _N_J `AS NOTED <br />