6920 SEAWAY BLVD 2023 Plans 2024-03-07
>
Address Records
>
SEAWAY BLVD
>
6920
>
Plans
>
6920 SEAWAY BLVD 2023 Plans 2024-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2024 2:04:39 PM
Creation date
3/7/2024 2:04:25 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6920
Permit
M2301-077
Year
2023
Notes
REPLACE (1) WATER COOLED CHILLER WITH NEW
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Z <br /> O <br /> FLAG NOTES F. <br /> EXIST. 7EMERGENCY TEMPORARY CHILLER O J cN <br /> BAS BYPASS CONNECTIONS.SEE DESIGN W a m rn <br /> EXIST. CRITERIA MECHANICAL SCOPE FOR uJ <br /> CONTROL ADDITIONAL DETAILS. <br /> PANEL---,..,,,,,,.......„.., <9 SAME SIZE AS EXISTING .. J Y cn I- <br /> --. <br /> TVFD I a .a) U. D D w <br /> (NEW) CTT U tJi co w <br /> V 1 <br /> m <br /> —CWR CWS COOLING TOWER CR— <br /> 2 (CCP)CONTROL PANEL <br /> CHVFD = -e. CFS <br /> (NEW) $ — (NEW) N <br /> a- <br /> ,Rq STT COND. ItRTT '�` (NEW)CHFS CVFD — eo <br /> (NEW) 4 (NEW) o <br /> C I EVAP. liTi Z <br /> 1 --c) STT L <br /> ITI I�a I SWITCHES I I �I In Ihot II o <br /> CHILLED WATER PUMP (CHP) CHILLER (CHL) CONDENSER WATER PUMP (CP) '`�� <br /> (NEW) (NEW) (NEW MOTOR) 140Pi gi <br /> w ° m< <br /> NOTE: ''U 5 a 6 Q,- <br /> DIAGRAM DOES NOT SHOW 'C Q F o ALL , <br /> • <br /> CHILLED WATER DIAGRAM THOSE EFRFECTEDTENANCES BY THIS <br /> ONLY <br /> PROJECT 'nQ. ajo <br /> SCALE:NTS <br /> U U <br /> O O <br /> SEQUENCE OF OPERATION <br /> g Q U O <br /> INTERLOCKS PUMPS SPEED RESET 0 <br /> PUMPS(CHILLED AND CONDENSER)WATER AND CHILLED AND CONDENSER WATER PUMPS SHALL BE w O <br /> COOLING TOWER SHALL BE INTERLOCKED WITH RESET BETWEEN 100 AND 70 PERCENT TO MAINTAIN CO <br /> CHILLER. CWR TEMPERATURE AT 54°F. Q 0 <br /> CC H <br /> ENABLE/DISABLE COOLING TOWER FAN d W Q <br /> CHILLER SHALL BE ENABLED ABOVE 55°F FAN SPEED SHALL BE ADJUSTED BETWEEN 100 AND D <br /> (ADJUSTABLE)TO MAINTAIN COMFORT CONDITIONS 70 PERCENT TO MAINTAIN 85°F CONDENSER WATER IY U Q <br /> WITHIN THE BUILDING.PUMPS(CHILLED AND LEAVING THE TOWER. W Q Y O <br /> CONDENSER)WATER AND COOLING TOWER SHALL d ;, Q <br /> ALSO BE ENABLED.BELOW 55°F.(ADJUSTABLE) a U LU E — <br /> CHILLER,PUMPS,AND TOWER SHALL BE DISABLED. <br /> Scale <br /> CHILLED WATER TEMPERATURE RESET AS NOTED <br /> CHILLED WATER TEMPERATURE RESET BASED ON ' �u <br /> Wof � Sheet <br /> OUTSIDE AIR TEMPERATURE PER THE FOLLOWING cr,. tk <br /> INITIAL RESET SCHEDULE:OSA=55°F.CWS=48°F. / : M4 of 5 <br /> OSA=80°F.CWS=44°F c 4q. <br /> CITY OF EVERETT <br /> REVIEWED FOR PERMIT <br />